Outback Power Systems HUB4, MATE_B, HUB10, MATE2 user manual Three-Phase Stacking Only

Page 10

Three-Phase Stacking Only

The OutBack HUB is shipped from the factory setup for series (120/240 VAC split phase) and/or parallel (120 VAC or 230 VAC single phase) stacking. If three-phase stacking is desired, the cover must be removed and a jumper position changed. For three-phase stacking using a HUB 4:

1.Remove the black snap on wiring cover and all cables plugged into the HUB. Label the cables to avoid confusion when

reconnecting.

2.Remove the four Phillips screws from the bottom of the HUB.

Bottom cover removed

3. Remove bottom cover and remove the four Phillips screws holding the green PCB to the upper cover.

PCB removed

Jumper

9

Image 10
Contents HUB Disclaimer About OutBack Power SystemsContact Information Warranty Introduction Dear OutBack CustomerEU Declaration of Conformity Accordance with ENOutback HUB Communications ManagerIntroduction HUB 10 and HUB 4 Parts AccessoriesMounting HUB Operation Connecting to the HUBHUB Ports HUB Common Wiring Configurations Three-Phase Stacking Only HUB 10 PCB Mate Power Up Sample Network ConfigurationFLEXware 1000 System Adding a Device to an Operating HUB Press the Mate soft keyProblem TroubleshootingAction TWO Year Limited Warranty Information Revision.2008-04-01 Limited Warranty Registration HUB Communcations ManagerPage REV B