Panasonic PB305, AW-PB301 manual Viewfinder Output Signal Select EVF Output Y/CVBS

Page 13

1 23

45

The inner frame indicates a safety zone of about 90% and the outer frame, a safety zone of about 95%.

Note: The safety zone and center marker indicate electrical positions, which may differ from opti- cal positions.

rViewfinder Output Signal Select [EVF Output: Y/CVBS]

Y: Luminance signals are output to the viewfinder.

CVBS: Color signals are output to the viewfinder. No zebra indicator will be shown.

tComponent Output Select [Component Output: R/G/B, Y/Pr/Pb, Y/C] (AW-PB301 only) Component output signals can be selected. Component output signals are output from the inter- face/remote connector on the rear of the camera.

Note: R/G/B output or Y/Pr/Pb output will be posi- tive in reproduced image regardless of the set- tings made with [Nega/Posi Set] on the [Other Settings] submenu of the main menu.

-11-

Image 13
Contents AW-PB301/PB305 Lightning flash with arrowhead sym Contents Special Notes on Operation PrefacePrecautions Viewfinder standby switch ST.BY/ON Viewfinder connector EVFIntercom volume control Level Intercom connector IncomMounting Rear Panel Option card slot cover Connecting a Studio System Setup Procedures Output Signal Selection Menu Item SettingCamera Safety Zone Select Safety Zone 1 to 5/OFF Zebra Indicator Zebra Indicator OFF/ONAW-PB301 AW-PB305 Viewfinder Output Signal Select EVF Output Y/CVBS Appearance Standard Accessories SpecificationsN1098-0 7J1A215A