Panasonic LK-T Relays specifications Features, Specifications, Typical Applications

Page 1

LK-T

SLIM POWER RELAY

LK-T RELAYS

WITH HIGH INRUSH

CURRENT CAPABILITY

TV-8 CERTIFIED

 

24.0

11.0

.433

.945

25.0

.984

FEATURES

1.High inrush current capability

1) Operating load capability: inrush 118 A, steady 8 A

2) UL/C-UL TV-8 approved

2.High insulation resistance

1)Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch (In compliance with IEC65)

2)Surge withstand voltage between contact and coil: 10,000 V or more

3.High noise immunity realized by the card separation structure between contact and coil

4.Conforms to the various safety standards

UL, C-UL, TÜV, and SEMKO approved

SPECIFICATIONS

Contact

Arrangement

 

1 Form A

Initial contact resistance

Max. 100 mΩ

(By voltage drop 6 V DC 1 A)

 

Contact material

 

AgSnO2 type

 

Nominal switching

5 A 277 V AC

 

capacity

 

 

Rating

Max. switching power

1,385 V A

Max. switching voltage

277 V AC

(resistive load)

Max. switching current

8 A (120V AC)

 

 

Min. switching capacity#1

100 mA, 5 V DC

 

(Reference value)

 

 

Expected life

Mechanical (at 180 cpm)

106

Electrical (at 20 cpm)

 

(min. operations)

105

 

(at rated load)

 

Coil

Nominal operating power

250 mW

#1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.

Remarks

*1 Measurement at same location as “Initial breakdown voltage” section. *2 Detection current: 10mA

*3 Wave is standard shock voltage of ±1.2 50μs according to JEC-212-1981 *4 Excluding contact bounce time.

*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 μs

*6 Half-wave pulse of sine wave: 6 ms

*7 Detection time: 10 μs

*8 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to 1. Usage, transport and storage conditions in NOTES on page 3.

Characteristics

Max. operating speed

 

20 cpm (at rated load)

Initial insulation resistance*1

Min. 1,000 MΩ (at 500 V DC)

Initial *2

Between open

1,000 Vrms for 1 min.

contacts

 

breakdown

 

 

Between contact

 

voltage

4,000 Vrms for 1 min.

and coil

 

 

 

 

Initial surge voltage between contact

10,000 V

and coil*3

 

 

 

 

 

Operate time*4

 

 

Max. 15ms (at 20°C 68°F)

(at nominal voltage)

 

 

 

Release time (without diode)*4

Max. 5ms (at 20°C 68°F)

(at nominal voltage)

 

 

 

 

 

 

Max. 35°C with nominal coil

Temperature rise (at 70°C)

voltage and at 5 A contact

carrying current

 

 

 

 

 

 

(resistance method)

Shock

Functional*5

200 m/s2{approx. 20 G}

resistance

Destructive*6

1,000 m/s2{approx. 100 G}

 

Functional*7

10 to 55Hz

Vibration

at double amplitude of 1.5mm

 

 

resistance

Destructive

10 to 55Hz

 

at double amplitude of 1.5mm

 

 

 

Conditions for operation,

Ambient

–40°C to +70°C

transport and storage*8

temp.

–40°F to +158°F

(Not freezing and

Humidity

5 to 85% R.H.

condensing at low

 

 

Air

86 to 106 kPa

temperature)

 

 

pressure

 

 

 

Unit weight

 

 

Approx. 12 g .42 oz

TYPICAL

APPLICATIONS

Audio visual equipment

Flat TVs and audio equipment, etc.

Office equipment

Home appliances

ORDERING INFORMATION

 

 

Ex. LKT

1a

 

F

 

 

 

12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact arrangement

 

Protective construction

 

 

 

Coil voltage(DC)

 

 

 

 

 

 

 

 

 

 

1a: 1 Form A

 

F: Flux-resistant type

 

 

 

5, 9, 12, 24V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UL/C-UL, TÜV, SEMKO, TV-8 approved type is standard. Notes: 1. Standard packing Carton: 100 pcs. Case: 500 pcs.

2. 3 V, 6 V, and 18 V DC types are also available. Please consult us for details.

ds_61113_0004_en_lkt: 091008J

1

Image 1
Contents Specifications FeaturesTypical Applications Ordering InformationReference Data DimensionsUsage, transport and storage conditions Solder and cleaning conditionsCertification Others