4-(2). Electrical life test (UL508 TV-8 rating test)
Sample:
•Overload test
Load: 12 A 120 V AC (60 Hz), Inductive load (cosφ = 0.75) Operation frequency: 6 times/min (ON : OFF = 1 s : 9 s)
No. of operations: 50 ope.
•Endurance test
Load: 8A 120 V AC (960 W lamp load),
(Inrush: 118 A)
Operation frequency: 1 times/min
(ON: OFF = 1 s: 59 s)
No. of operations: 25,000 ope.
Change of
V | 12 |
|
|
|
|
|
| |
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||
voltage, | 10 |
|
|
|
|
|
| |
|
|
|
| Pick |
| Max. | ||
8 |
|
|
| |||||
|
|
|
|
| ||||
|
|
|
|
|
| x | ||
drop |
|
|
|
|
|
| Min. | |
6 |
|
|
|
|
|
| ||
|
|
|
|
|
| |||
up and |
|
|
|
|
|
| ||
4 |
|
|
|
|
|
| ||
|
|
|
|
|
| |||
- |
|
|
|
|
|
|
| |
Pick |
|
|
| Drop |
| Max. | ||
|
|
|
|
|
| |||
|
| 2 |
|
|
|
|
| |
|
|
|
|
|
|
| x | |
|
|
|
|
|
|
|
| Min. |
|
| 00 |
|
|
|
|
| |
|
|
|
|
| 25 | |||
|
|
|
|
| No. of operations, ⋅103 |
|
| |
|
|
|
|
|
|
|
Change of contact resistance
|
| 50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
mΩ | 45 |
|
|
|
|
|
| |
|
|
|
|
|
| |||
40 |
|
|
|
|
|
| ||
|
|
|
|
|
| |||
resistance, | 35 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
| 30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Contact | 25 |
|
|
|
|
|
| |
|
|
|
|
|
| |||
20 |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
| 15 |
|
|
|
| Max. | |
|
|
|
|
|
| |||
|
| 10 |
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
| x | ||
|
| 5 |
|
|
|
| Min. | |
|
|
|
|
| ||||
|
| 00 |
|
|
|
|
| |
|
| 25 |
| |||||
|
|
|
|
| No. of operations, ⋅103 | |||
|
|
|
|
|
NOTES
1.Usage, transport and storage conditions
1) Temperature:
3) Atmospheric pressure: 86 to 106 kPa Temperature and humidity range for usage, transport, and storage
Humidity, %RH
85
Tolerance range
|
|
|
|
|
|
|
(Avoid freezing |
| (Avoid |
| |||
when used at |
| condensation |
| |||
temperatures lower | when used at |
| ||||
than 0°C 32°F) |
| temperatures higher | ||||
|
|
| 5 | than 0°C 32°F) |
| |
|
|
|
|
|
| |
| 0 |
|
| 70 | ||
| +32 |
| +158 |
Temperature, °C °F
4) Condensation
Condensation forms when there is a sudden change in temperature under high temperature and high humidity conditions. Condensation will cause deterioration of the relay insulation.
5) Freezing
Condensation or other moisture may freeze on the relay when the temperatures is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags.
6)Low temperature, low humidity environments
The plastic becomes brittle if the relay is exposed to a low temperature, low humidity environment for long periods of time.
2.Solder and cleaning conditions
1) Please obey the following conditions when soldering automatically.
(1) Preheating: Within 120°C 248°F (solder surface terminal portion) and within 120 seconds
(2) Soldering iron: 260°C±5°C
500°F±41°F (solder temperature) and within 6 seconds (soldering time)
2) Since this is not a sealed type relay, do not clean it as is. Also, be careful not to allow flux to overflow above the PC board or enter the inside of the relay.
3.Certification
1)This relay is UL and
UL,
2)This relay is certified by TUV as an electromagnetic relay that complies with VDE0435 (File No. B040413461035).
(1) TUV rating: 8A, 250 V to COSφ = 1.0
(2) The terminals of this relay can only be connected with solder.
(3) This relay is certified by SEMKO (File No. 400968).
SEMKO rating: 3/100A 250 V AC, 5/40A 250 V AC
4. Others
1)For precautions regarding use and explanations of technical terminology, please refer to “Relay Technical Information”.
2)To ensure good operation, please keep the voltage on the coil ends to ±5% (at 20°C 68°F) of the rated coil operation voltage. Also, please be aware that the
3)Keep the ripple rate of the nominal coil voltage below 5%.
4)The cycle lifetime is defined under the standard test condition specified in the JIS* C 5442 standard (temperature 15 to 35°C 59 to 95°F, humidity 25 to 75%). Check this with the real device as it is affected by coil driving circuit, load type, activation frequency, activation phase,ambient conditions and other factors.
Also, be especially careful of loads such as those listed below.
(1) When used for AC
(2)
Three countermeasures for these are listed here.
• Incorporate an
• Lower the operating frequency
• Lower the ambient humidity
5)Heat, smoke, and even a fire may occur if the relay is used in conditions outside of the allowable ranges for the coil ratings, contact ratings, operating cycle lifetime, and other specifications. Therefore, do not use the relay if these ratings are exceeded.
6)If the relay has been dropped, the appearance and characteristics should always be checked before use.
7)Incorrect wiring may cause unexpected events or the generation of heat or flames.
For Cautions for Use, see Relay Technical Information.
ds_61113_0004_en_lkt: 091008J | 3 |