•Changing Switch Settings on Pan/tilt Head q Remove the cover from the pan/tilt head.
* Be careful of the Tally Indicator wire.
Tally Indicator
wShift the mounting direction switches (SW1, SW2) on the pan/tilt head depending on whether the head is suspended from the ceiling or mounted on the floor. They are originally set for suspended installation.
ePlace the cover back on the pan/tilt head. * Be sure not to trap the wires.
DESKTOP SW1 SW2
SW1 SW2 SW3
HANGING
•If the pan/tilt head is connected to the control panel with a cable longer than 300 meters, set the cable compensation switch on the pan/tilt head to the ON position in advance. If the distance between the pan/tilt head and the control panel is shorter than 300 meters, keep the switch in the original position (OFF). For details on shifting the switch, refer to the figure below or the Operating Instructions for Pan/tilt Head.