Panasonic PT-EX16K manual Response data Data section Blank Mode Termination symbol

Page 25

Control commands via LAN (continued)

When WEB Control administrator rights password is not set (Non-protect mode)

Connection method

1)Obtain the IP address and port number (Initial set value = 1024) of the projector and make a request for connection to the projector.

Acquire the IP address from the menu screen of the projector, and the port number from the WEB control page.

IP address : Obtain from MAIN MENU → [Network] → [Network status]

Port No. : Acquire from the WEB control “Detailed set up” → “Command port setting” page

2) There is a response from the projector.

Response data

Data section

Blank

Mode

Termination symbol

“NTCONTROL”

‘  ’

‘0’

(CR)

(ASCII string)

0x20

0x30

0x0d

9 bytes

1 byte

1 byte

1 byte

Mode : 0 = Non-protect mode

Command transmission method

Transmit by the following command format.

Transmitted data

Header

 

 

Data section

Termination symbol

‘0’

 

‘0’

 

Control command

(CR)

0x30

 

0x30

 

(ASCII string)

0x0d

1 byte

 

1 byte

 

Undefined length

1 byte

Receive data

 

 

 

 

Header

 

 

Data section

Termination symbol

‘0’

 

‘0’

 

Control command

(CR)

0x30

 

0x30

 

(ASCII string)

0x0d

1 byte

 

1 byte

 

Undefined length

1 byte

Receive data

 

 

 

 

 

 

Error message

 

Termination symbol

“ERR1”

Undefined control command

 

“ERR2”

Out of parameter range

 

 

“ERR3”

Busy state or no-acceptable period

(CR)

“ERR4”

Timeout or no-acceptable period

0x0d

“ERR5”

Wrong data length

 

 

“ERRA”

Password mismatch

 

 

 

 

4 bytes

 

1 byte

25

Image 25
Contents Operating Instructions Contents Request Regarding Security Command controlWhat you can do WEB control SeeComputer without a built-in wired LAN function  Wired LAN Check 1 For LAN cableCheck your computer Necessary environment for computers to be connectedNetwork menu Press the Menu button on remote controlDisplaying the Network menu Press the Select buttonPress to select Projector name, and press Select button Projector name Default wired LAN settings Network setupDefault gateway  IP address Network control Network status Network factory default Connecting with Wired LANComputer operation Accessing from the Web browser Using Web BrowserProjector status Using Web BrowserParameter Description Error informationBasic control Detail control  Administrator mode  User account  User mode Change PasswordComplete the detailed settings and click Next Network configClick Submit Ping test LAMP1-4 Runtime Mail setupLamp 1-4 Runtime Authentication set upContents of mail sent Command port set up PJLink security authorization Control commandsCommand Control details PJLink protocolCommand transmission method Control commands via LANThere is a response from the projector Receive data Error message Termination symbol Response data Data section Blank Mode Termination symbolTrademarks GlossaryDescriptions See ヱㄏㄔㄐㄏㄊチヤㄐㄓㄑㄐㄓㄕㄊㄐㄏ