Panasonic PT-F100 „ Respone Callback, „ Response Callback, „ Notes, „ Parameters *1, *2

Page 3

2. Basic Control Command

Explanatory notes

Yes: Enable

No: Disable

2.1. Power ON (Lamp ON)

Hexadecimal

02h

50h

4Fh

4Eh

03h

Character

 

P

O

N

 

„ Respone (Callback)

In the period when the command can be accepted (This command in power-on condition is included)

Hexadecimal

02h

50h

4Fh

4Eh

03h

Character

 

P

O

N

 

Acceptability

 

NO SIGNAL SHUTTER

REMOTE

SECURITY STANDBY

Yes

Yes

Yes

 

Yes

(Yes)

„ Note:

• When you confirm whether to have succeeded in power-on, confirm it by QPW (Query Power) command after receiving the callback of PON command.

• When REMOTE is effective, ER401 is returned as a response (callback).

2.2. Power OFF (Standby)

 

Hexadecimal

02h

50h

4Fh

46h

03h

 

Character

 

P

O

F

 

 

„ Response (Callback)

 

 

 

 

In the period when the command can be accepted (This command in power-off condition is included)

Hexadecimal

02h

50h

4Fh

46h

03h

Character

 

P

O

F

 

Acceptability

 

NO SIGNAL SHUTTER

REMOTE

SECURITY STANDBY

Yes

Yes

Yes

 

Yes

(Yes)

„ Notes:

• When you confirm whether to have succeeded in power-off, confirm it by QPW (Query Power) command after receiving the callback of POF command.

• When REMOTE is effective, ER401 is returned as a response (callback).

2.3. AUTO SETUP

Hexadecimal

02h

4Fh

41h

53h

03h

Character

 

O

A

S

 

„ Response (Callback)

In the period when the command can be accepted

 

 

 

 

 

Hexadecimal

02h

4Fh

41h

53h

03h

 

 

 

 

Character

 

 

O

A

S

 

 

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STANDBY

 

NO SIGNAL

SHUTTER

REMOTE

 

 

No

 

No

 

No

 

 

No

Yes

 

„ Note:

• This command is acceptable only when RGB1 or RGB2 is selected and RGB PC signals are input. In other cases, ER401 is returned.

2.4. SHUTTER key

Hexadecimal

02h

4Fh

53h

48h

3Ah

*1

03h

Character

 

O

S

H

:

*2

 

„ Parameters (*1, *2)

Hexadecimal

Shutter OFF

Shutter ON

30h

31h

Character

0

1

„ Response (Callback)

In the period when the command can be accepted

 

 

 

 

 

 

Hexadecimal

 

02h

 

4Fh

 

53h

 

48h

 

3Ah

 

*1

03h

 

Character

 

 

 

O

 

 

S

 

H

 

:

 

*2

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STANDBY

NO SIGNAL

 

SHUTTER

REMOTE

 

 

 

No

 

No

 

Yes

 

 

Yes

 

Yes

 

 

3/16

Image 3
Contents Panasonic Projector RS-232C Control Specifications Byte Bytes„ Notes „ Respone Callback„ Note „ Response CallbackVideo „ Parameters *1, *2, *3, *4, *5, *6Down  key Index Window key „ Acceptability „ ParametersQuery Lamp Status Parameters *1, *2, *3, *4 Query Audio Volume Level10/16 11/16 12/16 „ Parameters *1, *2, *3, *4 „ Parameters *1, *2, *3, *4, *5, *6, *7, *813/16 14/16 15/16 „ ResponseCallback16/16 „ Parameters*1, *2