2.20. Audio Volume Level

Hexadecimal

02h

41h

56h

4Ch

3Ah

*1

*3

*5

03h

Character

 

A

V

L

:

*2

*4

*6

 

„ Parameters (*1, *2, *3, *4, *5, *6)

Hexadecimal

30h

0

30h

30h

1

31h

30h

2

32h

30h

30h

30h

Character

0

0

0

0

0

1

0

0

2

Hexadecimal

30h

61

31h

30h

62

32h

30h

63

33h

36h

36h

36h

Character

0

6

1

0

6

2

0

6

3

„ Response (Callback)

In the period when the command can be accepted

 

 

 

 

 

 

 

 

 

Hexadecimal

02h

41h

56h

4Ch

3Ah

 

 

*1

*3

*5

03h

 

 

Character

 

 

A

V

L

:

 

 

*2

*4

*6

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STANDBY

 

NO SIGNAL

SHUTTER

REMOTE

 

 

 

 

 

 

No

 

No

 

No

 

 

No

Yes

 

 

 

 

 

„Notes:

• STANDBY is valid when AUDIO IN STANDBY in EXT OPTION is “ON”.

2.21. Set Date

Hexadecimal

02h

54h

53h

44h

3Ah

*y1

*y2

*y3

Character

*y4

T

S

D

:

*w

03h

 

Hexadecimal

*m1

*m2

*d1

*D2

 

Character

 

 

 

 

 

 

 

 

„Parameters

*y1 - *y4: Year (4 digits)

*m1, *m2: Month (2 digits)

*d1, *d2: Day (2 digits)

*w: Day of the week (Mon = 1, Tue = 2, Wed = 3, Thu = 4, Fri = 5, Sat = 6, Sun = 7) Set it by UTC (Coordinated Universal Time).

Example: Thursday, June 29, 2006

Hexadecimal

*y1

*y2

*y3

*y4

*m1

*m2

*d1

*D2

*w

32h

30h

30h

36h

30h

36h

32h

39h

34h

Character

2

0

0

6

0

6

2

9

4

„Response (Callback)

In the period when the command can be accepted

 

 

 

 

 

 

 

Hexadecimal

02h

 

54h

53h

 

44h

 

3Ah

 

*y1

*y2

*y3

 

Character

 

 

T

 

S

 

D

 

:

 

 

 

 

 

Hexadecimal

*y4

 

*m1

*m2

 

*d1

 

*d2

 

*w

03h

 

 

Character

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STANDBY

NO SIGNAL

SHUTTER

REMOTE

 

 

 

 

 

No

 

Yes

 

Yes

 

 

Yes

 

Yes

 

 

 

 

2.22. Set Time

Hexadecimal

02h

54h

53h

54h

3Ah

*h1

Character

*h2

T

S

T

:

03h

Hexadecimal

*m1

*m2

*s1

*s2

Character

 

 

 

 

 

 

„Parameters

*h1, *h2: Hour (2 digits)

*m1, *m2: Minute (2 digits)

*s1, *s2: Second (2 digits)

Set it by UTC (Coordinated Universal Time). Example: 3 seconds at 3:45 p.m.

Hexadecimal

*h1

*h2

*m1

*m2

*s1

*s2

31h

35h

34h

35h

30h

33h

Character

1

5

4

5

0

3

„Response (Callback)

In the period when the command can be accepted

Hexadecimal

02h

54h

53h

54h

3Ah

*h1

Character

*h2

T

S

T

:

03h

Hexadecimal

*m1

*m2

*s1

*s2

Character

 

 

 

 

 

 

„Acceptability

SECURITY

STANDBY

NO SIGNAL

SHUTTER

REMOTE

No

Yes

Yes

Yes

Yes

2.23. Query Power

Hexadecimal 02h 51h 50h 57h 03h

7/16

Image 7
Contents Panasonic Projector RS-232C Control Specifications Byte Bytes„ Notes „ Respone Callback„ Note „ Response CallbackVideo „ Parameters *1, *2, *3, *4, *5, *6Down  key Index Window key „ Acceptability „ ParametersQuery Lamp Status Parameters *1, *2, *3, *4 Query Audio Volume Level10/16 11/16 12/16 „ Parameters *1, *2, *3, *4, *5, *6, *7, *8 „ Parameters *1, *2, *3, *413/16 14/16 15/16 „ ResponseCallback16/16 „ Parameters*1, *2