Cabletron Systems CSX200, CSX400 manual Restricted Rights Notice

Page 5

ANNEX, ANNEX-II, ANNEX-IIe, ANNEX-3, ANNEX-802.5, MICRO-ANNEX-XL, and MICRO- ANNEX-ELS are trademarks of Xylogics, Inc.

MAXserver and Xyplex are trademarks of Xyplex, Inc.

Restricted Rights Notice

(Applicable to licenses to the United States Government only.)

1.Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013.

Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03867-0505.

2.(a) This computer software is submitted with restricted rights. It may not be used, reproduced, or disclosed by the Government except as provided in paragraph (b) of this Notice or as otherwise expressly stated in the contract.

(b)This computer software may be:

(1)Used or copied for use in or with the computer or computers for which it was acquired, including use at any Government installation to which such computer or computers may be transferred;

(2)Used or copied for use in a backup computer if any computer for which it was acquired is inoperative;

(3)Reproduced for safekeeping (archives) or backup purposes;

(4)Modified, adapted, or combined with other computer software, provided that the modified, combined, or adapted portions of the derivative software incorporating restricted computer software are made subject to the same restricted rights;

(5)Disclosed to and reproduced for use by support service contractors in accordance with subparagraphs (b) (1) through (4) of this clause, provided the Government makes such disclosure or reproduction subject to these restricted rights; and

(6)Used or copied for use in or transferred to a replacement computer.

(c)Notwithstanding the foregoing, if this computer software is published copyrighted computer software, it is licensed to the Government, without disclosure prohibitions, with the minimum rights set forth in paragraph (b) of this clause.

(d)Any other rights or limitations regarding the use, duplication, or disclosure of this computer software are to be expressly stated in, or incorporated in, the contract.

(e)This Notice shall be marked on any reproduction of this computer software, in whole or in part.

iii

Image 5
Contents CSX200 and CSX400 User’s Guide Page Virus Disclaimer Page Restricted Rights Notice Page Contents Chapter Bridging Vii Token Ring Physical Status Fields IndexIntroduction HSIM-W6 and HSIM-W84 Using the CSX 200 and CSX400 User’s GuideRelated Manuals Device Name Software ConventionsCommon Window Fields IP Address Using the MouseLocation MAC AddressUsing Window Buttons Getting Help from the Cabletron Systems Global Call Center Using On-line HelpGetting Help CSX200 and CSX400 Firmware CSX200 and 400 Chassis View CSX200 and CSX400 Chassis View Windows Viewing Chassis InformationFront Panel Information Date Menu StructureTime Port Status Menu Device MenuPort Menus Utilities MenuHelp Menu Status CSX200/400 Port Status DisplaysSelecting a Port Status View Load Port Status Color Codes Chassis Manager WindowDevice Type Viewing Hardware TypesViewing the Port Description Managing the DeviceViewing I/F Summary Information Using the Find Source Address FeatureDescription IndexLogical Status Physical StatusInterface Performance Statistics/Bar Graphs Raw CountsRate Detail Interface Statistics Viewing Interface DetailAddress ErrorUnicast Non-UnicastMaking Sense of Detail Statistics Enabling and Disabling PortsPackets Transmitted Transmit only CSX200 and 400 Chassis View CSX200 and 400 Chassis View Managing the Device About the CSX200 Series CSX200 and CSX400 WAN ConfigurationWAN Redundancy About the CSX400WPIM-DDS CSX WPIMsEIA-RS449 WAN Logical View Window WAN Logical ViewWAN Logical View Window Fields Changing WAN Logical SettingsCSX200 and CSX400 WAN Configuration CSX200 and CSX400 WAN Configuration WAN Logical View Bridging Basics BridgingAbout Source Route Bridging About Transparent BridgingBridging About Source Route-Translational Bridges About Source Route-Transparent BridgesBridging Viewing and Managing Bridging Interfaces Bridging Bridge Status Window Information Fields Bridge Status WindowBridge State on Interface Up TimeBridge Address Accessing Other Options from the Bridge Status WindowInterface Type Bridging Bridging Bridging From the Bridge Status window Enabling and Disabling BridgingEnabling and Disabling Individual Interfaces Bridge Statistics Enabling and Disabling All Installed InterfacesPerformance Graphs From the Chassis View windowFrom the Bridge Status window Filtered Magenta Bridge Performance Graph Window FieldsFrames Forwarded Green Xmitted Blue Errors RedConfiguring the Bridge Performance Graphs Bridge Detail Breakdown WindowFiltered Frames ForwardedBridge Port Detail Breakdown Window XmittedForwarded to Forwarded fromI/F Statistics Window Interface Statistics WindowStatistics Window Fields Unknown Protocol Csmacd Statistics WindowPackets Received Transmit Queue SizeAlignment Receive ErrorsTransmission Errors PPP Link Statistics Window Collision ErrorsBad Addresses ErrorsBad Controls Packets Too LongStatistics Dot5 Errors Statistics Window Burst Errors Line ErrorsCongestion Errors Internal ErrorsToken Errors Soft ErrorsSource Route Statistics Received Frames Bridge Source Routing Window FieldsSpecif. Routed All Paths ExplDiscards Transmitted FramesHop Cnt. Exceeded Bridge Spanning TreeBridge Priority Configuring the Bridge Spanning Tree WindowBridge Level Fields Root Port Root BridgeRoot Cost Bridge Port Level Fields Designated Cost Path CostDesignated Root Designated BridgeChanging the Spanning Tree Algorithm Protocol Type Changing Bridge Spanning Tree ParametersChanging Bridge Priority Changing Max Age Time Changing Forwarding Delay TimeChanging Hello Time Changing Path Cost Filtering DatabaseChanging Port Priority Bridging From the Bridge Status window List Filtering Database Window FieldsNumber CapacityAging Time Configuring the Filtering DatabaseSource Port Receive PortChanging the Type of Entry Altering the Aging TimeAdding or Deleting Individual Entries Changing the Receive PortChanging the Port Filtering Action Clearing All Permanent, Static, or Dynamic Entries Ethernet and Token Ring Special Filter DatabasesEthernet Special Filter Database Window 13. Ethernet Special Filter Database Window Token Ring Special Filter Database WindowSpecial Filter Database Window Fields EnableFile Destination AddressDefining and Editing Filters in the Special Database This Changing the Port Filtering Action Setting the Port Filtering ActionChanging the Receive Ports Clearing the Port Filtering Action Enabling and Disabling a FilterSaving a Set of Filters to a File Source Route Configuration 16. Source Route ConÞguration Window Information on Source RoutingSource Route Configuration Fields Source Route Configuration WindowLocal Segment Subnet MaskTarget Segment Hop Count LimitBridge Number Spanning Tree ExplSpanning Tree Mode Making and Setting Changes Using the Find Source Address FeaturePort Source Addresses Window Setting the Aging Time Duplex Modes Interface Duplex Modes WindowDuplex Modes Window Fields Full Duplex Setting the Duplex ModeEthernet Port Configuration Window Standard ModeFast Ethernet Port Configuration Link State Current Operational ModePort Type Remote Capabilities Desired Operational ModeAdvertised Abilities Setting the Desired Operational Mode for the FE-100FX Setting the Desired Operational Mode for the FE-100TXSONET/SDH Configuration Sonet Port ConfigurationSonet SONET/SDH Statistics Window Bridging 24. The SONET/SDH Statistics Window Loss of Pointer Loss of SignalLoss of Frame Errored SecondsCode Violations Severely Errored SecondsSeverely Errored Framing Seconds Configuring Broadcast Suppression Token Ring Bridge Mode Defining the Bridge Modes Setting The Token Ring Bridge ModeTransparent Source RoutingEtwmim Ethernet Port Physical View Using the Physical View WindowsEthernet Port Physical Status Fields Active PortEpim Type Etwmim Token Ring Port Physical ViewRing State Token Ring Physical Status FieldsRing Speed Active Monitor FNB StateUsing the Interface Configuration Window 29. Interface ConÞguration Window Defining the Bridge MethodNetBIOS Setting the Bridge MethodDefining the Protocol Transmission OtherUsing the Bridge and Port Configuration Windows From the Bridge Status window Ring Number Virtual Ring NumberBridge Mode/Explorer Type Port ModeNovell Translation Configuring SmartTrunking Name PortSmartTrunk State ModeInstance # SmartTrunksBridging Bridging 100 Configuring SmartTrunking Index Index-2 Index-3 Index-4
Related manuals
Manual 88 pages 62.16 Kb Manual 275 pages 3.4 Kb

CSX200, CSX400 specifications

Cabletron Systems was a leading developer of networking solutions, and its CSX400 and CSX200 series of high-performance switches represent some of the key innovations in the field of enterprise networking during their time. Both models were geared towards enhancing network reliability, efficiency, and speed, particularly in environments where heavy data traffic and complex networking demands were prevalent.

The CSX400, designed for larger enterprises, boasts a robust architecture capable of handling significant throughput. One of its standout features is its stackable design, allowing multiple switches to be interconnected and managed seamlessly as a single unit. This scalability provides organizations with the flexibility to expand their networks without significant infrastructure overhauls. The CSX400 supports various Ethernet standards, including 10/100 Ethernet and Gigabit Ethernet, positioning it to effectively manage both legacy and modern networking requirements.

In addition to its scalability, the CSX400 is distinguished by its advanced Layer 2 and Layer 3 routing capabilities. This dual-layer functionality enables efficient data handling and is instrumental in managing traffic between different network segments. Moreover, the switch incorporates features like VLAN (Virtual Local Area Network) support and Quality of Service (QoS) prioritization, allowing for enhanced performance of critical applications and streamlined bandwidth allocation.

On the other hand, the CSX200 series is tailored for smaller enterprises or branch offices needing a reliable yet efficient networking solution. Despite its compact design, the CSX200 is equipped with essential features that promote effective network management and security. It offers a simplified management interface, making it user-friendly for network administrators. The switch also provides essential access control measures, employing technologies like IEEE 802.1X for network access security.

Both the CSX400 and CSX200 prioritize performance through the incorporation of advanced switching technologies. They support features such as Spanning Tree Protocol (STP), enabling loop-free topologies and enhanced network resilience. These attributes are particularly crucial in dynamic networking environments where downtime can have significant repercussions on business operations.

Overall, Cabletron Systems' CSX400 and CSX200 series represent a blend of scalability, advanced routing capabilities, and user-friendly management, making them vital assets for organizations looking to optimize their network infrastructure during a period of rapid technological evolution. With their rich feature sets and unwavering performance, these switches helped pave the way for modern networking solutions that cater to diverse enterprise needs.