Cabletron Systems CSX200, CSX400 manual Defining and Editing Filters in the Special Database

Page 99

Bridging

Data Type

Displays the hexadecimal two-byte Þeld for the Þlter which can be used to mask out a speciÞed protocol type Þeld. Examples of protocol type are:

¥0800 = IP

¥8137 = Novell

¥0bad = Banyan

¥80f3 = AppletalkARP

Data Offset

Indicates the offset (in bytes, from the beginning of the data in the packet) where the Data Mask will be applied. The default for this Þeld is 0000 (no data offset). An example of a valid offset to enter into this Þeld is 0016 (16 bytes).

Data Mask

Displays the 64-byte overlay used to Þlter packets. The Data Mask is applied to the packet after the Þxed part of the packet, which includes Source Address, Destination Address, and Type Þelds. The Þlter applies the mask directly at the start of the data portion of the packet unless there is a Data Offset. If a Data Offset has been deÞned, the mask will apply to the data that comes after the speciÞed offset in the packet.

Receive Port(s)

Indicates the ports at which the packet must be received for Þltering information to be applied. Note that you can only immediately see one receive port per Þlter, even though you can set more than one receive port for the Þltering action to apply. The receive port Þeld can display each device bridge port, BRIM port, or Ò*Ó. The Ò*Ó indicates that a packet can be received at any port for the Þlter to apply (i.e., the port is promiscuous).

Port Filtering

forwarding Indicates the forwarding/blocking information for the Þlter at each port on the device. Note that you can only view two ports at a time.

blocking

Use the scroll bar at the top of the column to view the

 

hidden ports.

Selected Filter

This Þeld, visible at the bottom of the window, displays the number of the Þlter that is currently highlighted. The possible range is from 01-19.

Defining and Editing Filters in the Special Database

You can edit an existing Þlter or deÞne a new Þlter using the following steps:

1.Click to select the filter you wish to edit. (The filter is selected when it is highlighted. When the bridge uses the Special Database, it starts with the lowest numbered enabled filter.)

Ethernet and Token Ring Special Filter Databases

4-53

Image 99
Contents CSX200 and CSX400 User’s Guide Page Virus Disclaimer Page Restricted Rights Notice Page Contents Chapter Bridging Vii Token Ring Physical Status Fields IndexIntroduction HSIM-W6 and HSIM-W84 Using the CSX 200 and CSX400 User’s GuideRelated Manuals Software Conventions Common Window FieldsDevice Name MAC Address Using the MouseIP Address LocationUsing Window Buttons Using On-line Help Getting HelpGetting Help from the Cabletron Systems Global Call Center CSX200 and CSX400 Firmware CSX200 and 400 Chassis View CSX200 and CSX400 Chassis View Windows Viewing Chassis InformationFront Panel Information Menu Structure TimeDate Port Status Menu Device MenuUtilities Menu Help MenuPort Menus CSX200/400 Port Status Displays Selecting a Port Status ViewStatus Load Port Status Color Codes Chassis Manager WindowDevice Type Viewing Hardware TypesViewing the Port Description Managing the DeviceViewing I/F Summary Information Using the Find Source Address FeatureDescription IndexRaw Counts Physical StatusLogical Status Interface Performance Statistics/Bar GraphsRate Detail Interface Statistics Viewing Interface DetailNon-Unicast ErrorAddress UnicastEnabling and Disabling Ports Packets Transmitted Transmit onlyMaking Sense of Detail Statistics CSX200 and 400 Chassis View CSX200 and 400 Chassis View Managing the Device About the CSX200 Series CSX200 and CSX400 WAN ConfigurationWAN Redundancy About the CSX400WPIM-DDS CSX WPIMsEIA-RS449 WAN Logical View Window WAN Logical ViewWAN Logical View Window Fields Changing WAN Logical SettingsCSX200 and CSX400 WAN Configuration CSX200 and CSX400 WAN Configuration WAN Logical View Bridging Basics BridgingAbout Source Route Bridging About Transparent BridgingBridging About Source Route-Translational Bridges About Source Route-Transparent BridgesBridging Viewing and Managing Bridging Interfaces Bridging Bridge Status Window Information Fields Bridge Status WindowBridge State on Interface Up TimeAccessing Other Options from the Bridge Status Window Interface TypeBridge Address Bridging Bridging Bridging Enabling and Disabling Bridging Enabling and Disabling Individual InterfacesFrom the Bridge Status window From the Chassis View window Enabling and Disabling All Installed InterfacesBridge Statistics Performance GraphsFrom the Bridge Status window Bridge Performance Graph Window Fields Frames Forwarded GreenFiltered Magenta Bridge Detail Breakdown Window Errors RedXmitted Blue Configuring the Bridge Performance GraphsFiltered Frames ForwardedForwarded from XmittedBridge Port Detail Breakdown Window Forwarded toI/F Statistics Window Interface Statistics WindowStatistics Window Fields Transmit Queue Size Csmacd Statistics WindowUnknown Protocol Packets ReceivedAlignment Receive ErrorsTransmission Errors PPP Link Statistics Window Collision ErrorsPackets Too Long ErrorsBad Addresses Bad ControlsStatistics Dot5 Errors Statistics Window Burst Errors Line ErrorsSoft Errors Internal ErrorsCongestion Errors Token ErrorsSource Route Statistics All Paths Expl Bridge Source Routing Window FieldsReceived Frames Specif. RoutedDiscards Transmitted FramesHop Cnt. Exceeded Bridge Spanning TreeConfiguring the Bridge Spanning Tree Window Bridge Level FieldsBridge Priority Root Bridge Root CostRoot Port Bridge Port Level Fields Designated Bridge Path CostDesignated Cost Designated RootChanging Bridge Spanning Tree Parameters Changing Bridge PriorityChanging the Spanning Tree Algorithm Protocol Type Changing Forwarding Delay Time Changing Hello TimeChanging Max Age Time Filtering Database Changing Port PriorityChanging Path Cost Bridging From the Bridge Status window Capacity Filtering Database Window FieldsList NumberReceive Port Configuring the Filtering DatabaseAging Time Source PortChanging the Type of Entry Altering the Aging TimeChanging the Receive Port Changing the Port Filtering ActionAdding or Deleting Individual Entries Clearing All Permanent, Static, or Dynamic Entries Ethernet and Token Ring Special Filter DatabasesEthernet Special Filter Database Window 13. Ethernet Special Filter Database Window Token Ring Special Filter Database WindowDestination Address EnableSpecial Filter Database Window Fields FileDefining and Editing Filters in the Special Database This Setting the Port Filtering Action Changing the Receive PortsChanging the Port Filtering Action Enabling and Disabling a Filter Saving a Set of Filters to a FileClearing the Port Filtering Action Source Route Configuration 16. Source Route ConÞguration Window Information on Source RoutingSource Route Configuration Fields Source Route Configuration WindowHop Count Limit Subnet MaskLocal Segment Target SegmentBridge Number Spanning Tree ExplSpanning Tree Mode Making and Setting Changes Using the Find Source Address FeaturePort Source Addresses Window Setting the Aging Time Duplex Modes Duplex Modes Window Duplex Modes Window FieldsInterface Full Duplex Setting the Duplex ModeEthernet Port Configuration Window Standard ModeFast Ethernet Port Configuration Current Operational Mode Port TypeLink State Desired Operational Mode Advertised AbilitiesRemote Capabilities Setting the Desired Operational Mode for the FE-100FX Setting the Desired Operational Mode for the FE-100TXSONET/SDH Configuration Sonet Port ConfigurationSonet SONET/SDH Statistics Window Bridging 24. The SONET/SDH Statistics Window Loss of Pointer Loss of SignalLoss of Frame Errored SecondsSeverely Errored Seconds Severely Errored Framing SecondsCode Violations Configuring Broadcast Suppression Token Ring Bridge Mode Source Routing Setting The Token Ring Bridge ModeDefining the Bridge Modes TransparentActive Port Using the Physical View WindowsEtwmim Ethernet Port Physical View Ethernet Port Physical Status FieldsEpim Type Etwmim Token Ring Port Physical ViewToken Ring Physical Status Fields Ring SpeedRing State Active Monitor FNB StateUsing the Interface Configuration Window 29. Interface ConÞguration Window Defining the Bridge MethodOther Setting the Bridge MethodNetBIOS Defining the Protocol TransmissionUsing the Bridge and Port Configuration Windows From the Bridge Status window Ring Number Virtual Ring NumberPort Mode Novell TranslationBridge Mode/Explorer Type Configuring SmartTrunking Name Port# SmartTrunks ModeSmartTrunk State InstanceBridging Bridging 100 Configuring SmartTrunking Index Index-2 Index-3 Index-4
Related manuals
Manual 88 pages 62.16 Kb Manual 275 pages 3.4 Kb

CSX200, CSX400 specifications

Cabletron Systems was a leading developer of networking solutions, and its CSX400 and CSX200 series of high-performance switches represent some of the key innovations in the field of enterprise networking during their time. Both models were geared towards enhancing network reliability, efficiency, and speed, particularly in environments where heavy data traffic and complex networking demands were prevalent.

The CSX400, designed for larger enterprises, boasts a robust architecture capable of handling significant throughput. One of its standout features is its stackable design, allowing multiple switches to be interconnected and managed seamlessly as a single unit. This scalability provides organizations with the flexibility to expand their networks without significant infrastructure overhauls. The CSX400 supports various Ethernet standards, including 10/100 Ethernet and Gigabit Ethernet, positioning it to effectively manage both legacy and modern networking requirements.

In addition to its scalability, the CSX400 is distinguished by its advanced Layer 2 and Layer 3 routing capabilities. This dual-layer functionality enables efficient data handling and is instrumental in managing traffic between different network segments. Moreover, the switch incorporates features like VLAN (Virtual Local Area Network) support and Quality of Service (QoS) prioritization, allowing for enhanced performance of critical applications and streamlined bandwidth allocation.

On the other hand, the CSX200 series is tailored for smaller enterprises or branch offices needing a reliable yet efficient networking solution. Despite its compact design, the CSX200 is equipped with essential features that promote effective network management and security. It offers a simplified management interface, making it user-friendly for network administrators. The switch also provides essential access control measures, employing technologies like IEEE 802.1X for network access security.

Both the CSX400 and CSX200 prioritize performance through the incorporation of advanced switching technologies. They support features such as Spanning Tree Protocol (STP), enabling loop-free topologies and enhanced network resilience. These attributes are particularly crucial in dynamic networking environments where downtime can have significant repercussions on business operations.

Overall, Cabletron Systems' CSX400 and CSX200 series represent a blend of scalability, advanced routing capabilities, and user-friendly management, making them vital assets for organizations looking to optimize their network infrastructure during a period of rapid technological evolution. With their rich feature sets and unwavering performance, these switches helped pave the way for modern networking solutions that cater to diverse enterprise needs.