Nortel Networks BCM 4.0 quick start Use and to set the DIP switches for the MBMs

Page 22

22Chapter 3 Physical installation

Use Table 6 and Table 7 to set the DIP switches for the MBMs.

Table 6 Possible trunk MBM DIP switch settings

DS30

 

 

 

 

 

Trunk MBM positioning

 

 

 

 

DIP switch settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bus #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4x16

 

DDIM

 

DTM

CTM4

CTM8

GATM

GATM8

BRI

 

 

 

 

 

 

Offsets

 

 

 

 

 

 

 

 

 

 

Offsets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0,1, 2, 3

 

Offset

 

Offset

Offsets

Offsets

Offsets

Offsets

Offsets

1

2

3

4

5

6

 

 

Line

Exten.

 

0

 

0

0, 1, 2,

0, 1, 2

0, 1, 2,

0, 1, 2

0, 1, 2,

(offset)

(DS30 #)

 

 

 

 

 

 

 

 

 

3

 

 

3

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Picks

0

 

Picks

 

0

0

0

 

0

0

 

0

on

on

on

on

on

on

0

 

1

up

 

 

up

 

 

1

 

1

1

 

1

1

on

on

off

on

on

on

1

2

ch. #3

 

 

ch. #3

 

 

 

 

2

 

 

 

 

2

2

 

2

2

 

2

on

off

on

on

on

on

2

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

3

 

 

3

 

 

 

on

off

off

on

on

on

3

 

0

Picks

0

 

Picks

 

0

0

0

 

0

0

 

0

on

on

on

on

on

off

0

 

1

up

 

 

up

 

 

1

 

1

1

 

1

1

on

on

off

on

on

off

1

3

ch. #4

 

 

ch. #4

 

 

 

 

2

 

 

 

 

2

2

 

2

2

 

2

on

off

on

on

on

off

2

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

3

 

 

3

 

 

 

on

off

off

on

on

off

3

 

0

Picks

0

 

Picks

 

0

0

0

 

0

0

 

0

on

on

on

on

off

on

0

 

1

up

 

 

up

 

 

1

 

1

1

 

1

1

on

on

off

on

off

on

1

4

ch. #5

 

 

ch. #5

 

 

 

 

2

 

 

 

 

2

2

 

2

2

 

2

on

off

on

on

off

on

2

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

3

 

 

3

 

 

 

on

off

off

on

off

on

3

 

0

Picks

0

 

Picks

 

0

0

0

 

0

0

 

0

on

on

on

on

off

off

0

 

1

up

 

 

up

 

 

1

 

1

1

 

1

1

on

on

off

on

off

off

1

5

ch. #6

 

 

ch. #6

 

 

 

 

2

 

 

 

 

2

2

 

2

2

 

2

on

off

on

on

off

off

2

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

3

 

 

3

 

 

 

on

off

off

on

off

off

3

 

0

Picks

0

 

Picks

 

0

0

0

 

0

0

 

0

on

on

on

off

on

on

0

 

1

up

 

 

up

 

 

1

 

1

1

 

1

1

on

on

off

off

on

on

1

6

ch. #7

 

 

ch. #7

 

 

 

 

2

 

 

 

 

2

2

 

2

2

 

2

on

off

on

off

on

on

2

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

3

 

 

3

 

 

 

on

off

off

off

on

on

3

 

 

 

 

 

 

 

0

0

0

 

0

0

 

0

on

on

on

off

on

off

0

7*

 

Not

 

 

Not

 

 

1

 

1

1

 

1

1

on

on

off

off

on

off

1

supported

supported

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

2

 

2

2

 

2

on

off

on

off

on

off

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

3

 

 

 

on

off

off

off

on

off

3

MBM set to offset 0 MBM set to offset 1 MBM set to offset 2 MBM set to offset 3

Each shaded square represents the amount of the DS30 buses, and the offset, which the MBM requires.

*If your system is configured with a 3/5 DS30 split, DS30 bus 7 is not available to MBM and DS30 bus 6 is not supported for the 4x16 and DDIM.

N0060602

Image 22
Contents BCM 4.0 Installation Checklist and Quick Start Guide Copyright 2006 Nortel Networks, All Rights Reserved BCM 4.0 Installation Checklist and Quick Start Guide Software LicenseN0060602 Contents Contents Purpose PrecautionsAbout this guide AudienceGetting started Installation and configuration summaryInstallation and configuration checklist Sheet 1 Task Reference CommentsDefault IP addresses Default valuesInstallation and configuration checklist Sheet 2 Default user names and passwordsSystem information Sheet 1 Tools, data, and parametersDescription Value Comments Main unit components checklist ChecklistsGeneral checklist Getting started System information Sheet 2Expansion unit and media bay modules components checklist BCM200 main unit ports and connectors Main unitsBCM expansion unit BCM400 only System overviewElement Manager Startup ProfileSystem overview N0060602 Installing a BCM unit in a rack Mounting a BCM main unit and expansion unitTo mount a BCM unit in an equipment rack Physical installationTo attach the rack-mount brackets Minutes/unitInstalling a BCM unit on a wall To install a BCM unit on a wallInstalling a BCM unit on a flat surface Attach the wall-mount bracket to the BCM400 main unitTo install a BCM unit on flat surface Connecting the expansion unit to the main unitInstalling the MBMs Chapter Physical installationUse and to set the DIP switches for the MBMs Possible trunk MBM DIP switch settingsOffsets 0 Bus # Possible station MBM DIP switch settingsDS30 Offset DS30 # OffsetsTo install MBMs Connecting the MBM wiringMinutes/MBM To connect the DTM, CTM, BRIM, or 4x16 MBMs DTM RJ-48C wiring array To connect the Gatm ASM and DSM wiring chart Sheet 1To connect the DSM16, DSM32, ASM8, GASM8, or 4x16 MBMs For ASM only Physical installation ASM and DSM wiring chart Sheet 2For DSM only Wiring the FEM Powering up the BCM systemTo connect the fiber cables To power up the BCM system Connecting the data networking hardwareTo connect the BCM system to the WAN To connect the modem Unpacking, placing, and wiring telephone hardwareTo install telephones Minutes/telephoneTo install optional telephony equipment Connection and configuration procedures Connecting to the BCM systemConnecting through the serial port Connecting through the Ethernet crossover cableTo configure your computer Connection and configuration proceduresTo connect through the serial port To download and install BCM Element Manager To access the BCM webDownloading from the BCM web To download the Startup Profile template Configuring the BCM system parametersGenerating a software keycode MinuteSystem IP addressModem Telephony startupSnmp Agent To configure the BCM system using BCM Element ManagerIP Phones Snmp communityConnection and configuration procedures Connection and configuration procedures Startup Profile times and LED sequence Configuring the MBMsTo configure the MBMs Startup Profile times and LED sequenceCustomizing other parameters Telephony ResourcesConnection and configuration procedures N0060602
Related manuals
Manual 19 pages 46.46 Kb

BCM 4.0 specifications

Nortel Networks BCM 4.0, or Business Communications Manager, is a robust telecommunications solution designed for small to medium-sized businesses (SMBs). This system combines voice and data capabilities in one unified platform, providing businesses with a powerful tool to enhance their communication processes.

One of the key features of BCM 4.0 is its ability to integrate various communication channels. It supports IP telephony, traditional telephony, and even cellular voice services, ensuring that businesses can leverage multiple forms of communication without needing separate systems. This unified approach reduces costs and simplifies management, making it easier for businesses to maintain their operations.

Another significant characteristic of BCM 4.0 is its multimedia capabilities. The system can handle voice, video, and data, delivering a comprehensive communication solution. This allows for seamless collaboration among employees, whether they are in the office or working remotely. The inclusion of multimedia applications enhances productivity by accommodating different communication preferences and needs.

Additionally, BCM 4.0 offers advanced call handling features, including call routing, auto-attendant, and voice mail systems. These functionalities improve customer service by ensuring that calls are efficiently managed and directed to the appropriate personnel. The system also provides extensive reporting tools, allowing businesses to monitor call activities and improve their communication strategies based on data-driven insights.

Security is a crucial consideration for any telecommunications system, and BCM 4.0 does not fall short in this area. It includes features such as secure SIP (Session Initiation Protocol) trunking, encryption, and user authentication. These security measures protect sensitive business information and ensure compliance with data protection regulations.

The modular architecture of BCM 4.0 is designed to grow with the business. Organizations can start with essential functionalities and easily upgrade or expand their systems as their needs evolve. This scalability feature makes BCM 4.0 an attractive option for businesses looking to invest in long-term solutions.

In summary, Nortel Networks BCM 4.0 is an integrated and versatile communications platform suited for SMBs. Its comprehensive features, multimedia capabilities, advanced call handling, robust security measures, and scalability make it a vital tool for enhancing business communications and driving productivity. By adopting BCM 4.0, businesses can streamline their operations and foster better engagement both internally and with their customers.