Epicenter 2x8, 2x16 user manual Specifications

Page 22

SPECIFICATIONS

ENVIRONMENTAL

Temperature

Operating: 32° to 104° F (0° to 40° C).

Non-operating: -4° to 140° F (-20° C to 60° C).

Humidity

Non-condensing, operating: 10 to 90%

Non-condensing, non-operating: 5 to 95%

Altitude

Operating: 0 to 10,000 ft (0 to 3048 m)

Non-operating: 0 to 30,000 ft (0 to 9144 m)

Audible Noise

Less than 60 dbA.

Heat Dissipation

85 Btu/hr maximum

Shock

Operating: 5 to 500 Hz, 0.5 g (0.1 oct/min)

Non-operating: 5 to 100 Hz, 1 g (0.1 octave/min); 100 to 500 Hz, 1.5g (0.2 octave/min); 500 to 1000 Hz, 1.5 g (0.2 octave/min)

ELECTRICAL

Grounding

Chassis grounded.

Voltage

100 to 240V AC.

Current

.5 Amps at 240V AC up to 1 Amps at 100V AC.

Line Frequency

Single phase 50 or 60 Hz.

COMPATIBILITY

XVGA 1024 x 768.

SVGA 800 x 600.

VGA 640 x 480

PS/2 Keyboard

PS/2 Mouse

Epicenter, Inc. Page 22

Image 22
Contents Installation and User’s Manual Epicenter, Inc. Centerpoint User Guide Table of Contents Introduction Using this Manual Safety Warnings and Cautions Product Features Rack Mount Installation Racks are coupled in multiple-rack installationsCable Lengths Connecting the CablesCenterpoint Connections Cable DescriptionON-SCREEN Controls AboutEdit Port Names Setup MenuEdit System Name Wakeup ServerMenu Position Menu Access KeyStatus Position Status Displays Change PasswordScreen Timeout Status SizeOperation Primary UserTftsetup and Controls Appendices ONE Year Warranty Factory Default Settings Installing Updates Fuse Replacement and Maintenance Fuse Value 250V, 2.0A MaximumEuropean Union Regulatory InformationIntended Use of Product InternationalSpecifications Connecting to a SUN Server Sun Key Epicenter Inc 211B Calle Pintoresco San Clemente, CA 92672