Dell H919N, K802N, K811N, K792N, J735N, 1000W, 2700W, J727N, H945N, 1920W, H928N, 2300W Safety Warnings

Page 10

SUnpacking the cabinet in a low-temperature environment may cause condensation to occur in and on the cabinet. Do not install the cabinet until the inside and outside of the cabinet are absolutely dry (hazard of electric shock).

SIf the UPS requires any type of transportation, disconnect the internal UPS batteries before transporting (see page 61).

CAUTION: Observe the following instructions to help prevent a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage incidents:

SFor PLUGABLE EQUIPMENT, the power outlet shall be installed near the equipment and shall be easily accessible.

SServicing of batteries should be performed or supervised by personnel knowledgeable about batteries and the required precautions. Keep unauthorized personnel away from batteries.

SBatteries can present a risk of electrical shock or burn from high short-circuit current. The following precautions should be observed: 1) Remove watches, rings, or other metal objects; 2) Use tools with insulated handles; 3) Wear rubber gloves and boots; 4) Do not lay tools or metal parts on top of batteries; 5) Disconnect the charging source prior to connecting or disconnecting battery terminals.

SDetermine if the battery is inadvertently grounded. If inadvertently grounded, remove the utility source from the ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance (applicable to equipment and remote battery supplies not having a grounded supply circuit).

SELECTRIC ENERGY HAZARD. Do not attempt to alter any battery wiring or connectors. Attempting to alter wiring can cause injury.

SReplace batteries with the same number and type of batteries as originally installed in the UPS.

SProper disposal of batteries is required. Refer to your local codes for disposal requirements.

SNever dispose of batteries in a fire. Batteries may explode when exposed to flame.

SDo not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes and may be extremely toxic.

SThe 1500–2700W UPS may be connected to a maximum of one External Battery Module (EBM).

10

Safety Warnings

Image 10
Contents Users Guide September 2009 S 164201787 Table of Contents RS-232 and USB Communication Ports Dell UPS Management SoftwareTesting Batteries UPS Status Menu Event Log MenuIntroduction Dell Line-Interactive Rack UPSIntroduction Finding Information What are You Looking For? Find It HereSafety Warnings UPS Output PowerSafety Warnings Safety Warnings Installation Inspecting the EquipmentUnpacking the Cabinet Unpacking the CabinetLifting the Cabinet Identifying the UPS Rear Panels 100V/120V Rear Panel120V, 1500W/100V Rear Panel 120V, 2300W/100V Rear Panel Identifying the UPS Front Panel Dell Line-Interactive Rack UPS Front PanelUPS Setup Rackmount SetupRemoving the Battery Tray Installing the Rails Installing the Cabinet Installing the Battery Tray Tower Setup Installing the UPS Front CoverConnect the internal battery connector Rotate the control panel 90 counterclockwise see Figure Carefully position the cabinet upright see Figure Installing the EBM Removing the Battery Connector CoverInstalling the Battery Connection Cover Installing the UPS Installing Remote Emergency Power-offRepo Connections Wire Function Repo ConnectorMinimum Upstream Circuit Breaker Rating UPS Output Power UPS Initial StartupPower Cord Ratings RatingAustralia Optional GB2099 to C13 CEE 7/7 Schuko to C19 Installation UPS Startup and Shutdown OperationStarting the UPS Starting the UPS on Battery UPS ShutdownControl Panel Functions Control Button Functions Control Button SequenceDisplay Functions Changing the LanguageStartup Screen Screen Locked UPS StatusUPS General Alarms Active Battery ModeBad Battery Detected or Battery Disconnected Battery Test StatusStandby Mode Status Summary Screens Description Normal ModeBattery Status Screens Description Event Log MeasurementsControl Screens Control Screens DescriptionSettings Description Available Settings Default Setting SettingsIdentification Settings Description Available Settings Default Setting Settings Description Available Settings Default Setting Settings Description Available Settings Default Setting Retrieving the Event Log Behavior on OverloadConfiguring Load Segments Controlling Load Segments Through the DisplayConfiguring Automatic Start Delay Configuring Automatic on Battery Shutdown Configuring Battery Settings Configuring the UPS for an EBMRunning Automatic Battery Tests Configuring Automatic RestartConfiguring Automatic Battery Tests Additional UPS Features RS-232 and USB Communication PortsRS-232 Communication Port Pin Assignment GNDDell Network Management Card Optional Dell Network Management CardDell UPS Management Software UPS Maintenance UPS and Battery CareTransporting the UPS Removing the UPS Front CoverDisconnect the internal battery connectors see Figure Storing the UPS and Batteries Replacing the UPS Front CoverTesting Batteries When to Replace BatteriesUpdating the UPS Firmware Specifications Electrical Input Efficiency Normal modePower Levels Nominal VoltageTemperature Relative Humidity Environmental and SafetyOperating Temperature Safety ConformanceVoltage Battery ConfigurationBattery Runtimes FusesAccessing Alarms and Conditions TroubleshootingUPS Status Menu Typical Alarms and Conditions Event Log MenuAction Troubleshooting Silencing the Alarm
Related manuals
Manual 63 pages 12.26 Kb Manual 71 pages 29.51 Kb

H928N, K811N, H919N, 1000W, 2700W specifications

Dell's power supply units (PSUs) are essential components for Dell servers and workstations, providing reliable power solutions tailored to meet different demands. Among these, the 500W, 1000W, and 1920W/1500W power supplies stand out for their efficiency, performance, and advanced features tailored to various IT environments.

Starting with the 500W power supply, this unit is designed for entry-level servers and workstations. It boasts a compact design that facilitates easy installation in space-constrained scenarios. The 500W PSU operates with a high efficiency rating, contributing to lower energy costs and reduced heat output. It supports the latest energy standards, including 80 PLUS certification, ensuring that customers can rely on it for consistent performance and reliability. This unit is particularly suitable for small to medium businesses looking for cost-effective power solutions for basic applications.

The 1000W power supply represents a step up, featuring dual 12V outputs that provide stable power for more demanding tasks. Designed for mid-range servers and advanced workstations, it balances performance and efficiency, making it ideal for enterprises that require additional processing power for virtualization, data analysis, and high-performance computing tasks. The 1000W PSU includes built-in protections against over-voltage, short circuits, and over-temperature conditions, adding an extra layer of reliability that is crucial for mission-critical operations.

For environments with higher power demands, Dell offers the 1920W/1500W power supply. This robust unit is engineered for high-performance servers and large-scale data centers, where maximum uptime and performance are paramount. The modular design of the 1920W/1500W power supply allows for enhanced cable management, reducing clutter and improving airflow within racks. With an efficiency rating that adheres to 80 PLUS Platinum standards, this PSU not only minimizes energy consumption but also maximizes operational efficiency, making it ideal for organizations looking to optimize their data center environments.

In summary, Dell's 500W, 1000W, and 1920W/1500W power supplies cater to a wide range of computing needs. From entry-level solutions to high-capacity units for demanding environments, Dell ensures that its power supplies provide reliability, efficiency, and performance. As organizations continue to evolve their IT infrastructure, these power supplies remain pivotal in supporting their growth and operational goals.