Dell 1000W, K802N Identification, Settings Description Available Settings Default Setting

Page 46

Identification

The identification screens display the following UPS information:

SType and model

SPart number

SSerial number

SUPS firmware

SNetwork Management Card firmware

NOTE: The NMC firmware screen displays only if the Network Management Card is installed. See “Dell Network Management Card“ on page 58.

Settings

Only available options are displayed.

User settings are not protected by default. You can enable the password through the User Password setting.

Table 7 displays the options that can be changed by the user.

Table 7. Settings

Description

Available Settings

Default Setting

 

 

 

Change Language

[English] [French] [German] [Spanish] [Japanese]

English

 

[Simplified Chinese] [Russian] [Korean]

 

 

[Traditional Chinese]

 

 

 

 

User Password

[Enabled] [Disabled]

Disabled

 

If Enabled, the default password is USER.

 

 

NOTE: If you enter an incorrect password, the

 

 

message “Wrong Password” appears. Press any

 

 

button to return to the password screen and retry

 

 

the password.

 

 

 

 

Audible Alarms

[Enabled] [Disabled]

Enabled

 

NOTE: If you disable audible alarms, it takes effect

 

 

instantly and remains disabled, even after a power

 

 

cycle. This differs from the mute feature where the

 

 

horn is temporarily silenced on any button press,

 

 

but turns on again if a new alarm is triggered.

 

 

 

 

46 Operation

Image 46
Contents Users Guide September 2009 S 164201787 Table of Contents RS-232 and USB Communication Ports Dell UPS Management SoftwareTesting Batteries UPS Status Menu Event Log MenuIntroduction Dell Line-Interactive Rack UPSIntroduction Finding Information What are You Looking For? Find It HereSafety Warnings UPS Output PowerSafety Warnings Safety Warnings Installation Inspecting the EquipmentUnpacking the Cabinet Unpacking the CabinetLifting the Cabinet Identifying the UPS Rear Panels 100V/120V Rear Panel120V, 1500W/100V Rear Panel 120V, 2300W/100V Rear Panel Identifying the UPS Front Panel Dell Line-Interactive Rack UPS Front PanelUPS Setup Rackmount SetupRemoving the Battery Tray Installing the Rails Installing the Cabinet Installing the Battery Tray Tower Setup Installing the UPS Front CoverConnect the internal battery connector Rotate the control panel 90 counterclockwise see Figure Carefully position the cabinet upright see Figure Installing the EBM Removing the Battery Connector CoverInstalling the Battery Connection Cover Installing the UPS Installing Remote Emergency Power-offRepo Connections Wire Function Repo ConnectorMinimum Upstream Circuit Breaker Rating UPS Output Power UPS Initial StartupPower Cord Ratings RatingAustralia Optional GB2099 to C13 CEE 7/7 Schuko to C19 Installation UPS Startup and Shutdown OperationStarting the UPS Starting the UPS on Battery UPS ShutdownControl Panel Functions Control Button Functions Control Button SequenceDisplay Functions Changing the LanguageStartup Screen Screen Locked UPS StatusUPS General Alarms Active Battery ModeBad Battery Detected or Battery Disconnected Battery Test StatusStandby Mode Status Summary Screens Description Normal ModeBattery Status Screens Description Event Log MeasurementsControl Screens Control Screens DescriptionSettings Description Available Settings Default Setting SettingsIdentification Settings Description Available Settings Default Setting Settings Description Available Settings Default Setting Settings Description Available Settings Default Setting Retrieving the Event Log Behavior on OverloadConfiguring Load Segments Controlling Load Segments Through the DisplayConfiguring Automatic Start Delay Configuring Automatic on Battery Shutdown Configuring Battery Settings Configuring the UPS for an EBMRunning Automatic Battery Tests Configuring Automatic RestartConfiguring Automatic Battery Tests Additional UPS Features RS-232 and USB Communication PortsRS-232 Communication Port Pin Assignment GNDDell Network Management Card Optional Dell Network Management CardDell UPS Management Software UPS Maintenance UPS and Battery CareTransporting the UPS Removing the UPS Front CoverDisconnect the internal battery connectors see Figure Storing the UPS and Batteries Replacing the UPS Front CoverTesting Batteries When to Replace BatteriesUpdating the UPS Firmware Specifications Electrical Input Efficiency Normal modePower Levels Nominal VoltageTemperature Relative Humidity Environmental and SafetyOperating Temperature Safety ConformanceVoltage Battery ConfigurationBattery Runtimes FusesAccessing Alarms and Conditions TroubleshootingUPS Status Menu Typical Alarms and Conditions Event Log MenuAction Troubleshooting Silencing the Alarm
Related manuals
Manual 63 pages 12.26 Kb Manual 71 pages 29.51 Kb

H928N, K811N, H919N, 1000W, 2700W specifications

Dell's power supply units (PSUs) are essential components for Dell servers and workstations, providing reliable power solutions tailored to meet different demands. Among these, the 500W, 1000W, and 1920W/1500W power supplies stand out for their efficiency, performance, and advanced features tailored to various IT environments.

Starting with the 500W power supply, this unit is designed for entry-level servers and workstations. It boasts a compact design that facilitates easy installation in space-constrained scenarios. The 500W PSU operates with a high efficiency rating, contributing to lower energy costs and reduced heat output. It supports the latest energy standards, including 80 PLUS certification, ensuring that customers can rely on it for consistent performance and reliability. This unit is particularly suitable for small to medium businesses looking for cost-effective power solutions for basic applications.

The 1000W power supply represents a step up, featuring dual 12V outputs that provide stable power for more demanding tasks. Designed for mid-range servers and advanced workstations, it balances performance and efficiency, making it ideal for enterprises that require additional processing power for virtualization, data analysis, and high-performance computing tasks. The 1000W PSU includes built-in protections against over-voltage, short circuits, and over-temperature conditions, adding an extra layer of reliability that is crucial for mission-critical operations.

For environments with higher power demands, Dell offers the 1920W/1500W power supply. This robust unit is engineered for high-performance servers and large-scale data centers, where maximum uptime and performance are paramount. The modular design of the 1920W/1500W power supply allows for enhanced cable management, reducing clutter and improving airflow within racks. With an efficiency rating that adheres to 80 PLUS Platinum standards, this PSU not only minimizes energy consumption but also maximizes operational efficiency, making it ideal for organizations looking to optimize their data center environments.

In summary, Dell's 500W, 1000W, and 1920W/1500W power supplies cater to a wide range of computing needs. From entry-level solutions to high-capacity units for demanding environments, Dell ensures that its power supplies provide reliability, efficiency, and performance. As organizations continue to evolve their IT infrastructure, these power supplies remain pivotal in supporting their growth and operational goals.