Dell K804N, K805N, J739N Battery Configuration, Battery Type, Voltage, Fuses, Charging, Monitoring

Page 65

Table 14. Battery

Configuration

3700W: (16) 12V, 7.2 Ah internal batteries; (16) 12V, 7.2 Ah EBM

 

4200W: (16) 12V, 7.2 Ah internal batteries; (16) 12V, 7.2 Ah EBM

 

 

Battery Type

CSB GP1272 7.2 Ah or YUASA NP7-12 7Ah

 

 

Voltage

3750W: 192 Vdc internal, 192 Vdc/30A EBM

 

4200W: 192 Vdc internal, 192 Vdc/30A EBM

 

 

Fuses

UPS: (1) 30A fuse

 

EBM: (1) 30A fuse

 

 

Type

Sealed, maintenance‐free, valve‐regulated, lead‐acid

 

 

Charging

Approximately 4 hours to 90% usable capacity at nominal line and no

 

supplementary power supply load

 

 

Monitoring

Advanced monitoring for earlier failure detection and warning

 

 

Battery Runtimes*

3750W internal batteries: 5 minutes at full load/21 minutes at half load

 

4200W internal batteries: 5 minutes at full load/16 minutes at half load

 

3750W with one EBM attached: 14 minutes at full load/43 minutes at half load

 

4200W with one EBM attached: 11 minutes at full load/35 minutes at half load

 

 

*Battery runtimes are approximate and vary depending on the load configuration and battery charge.

 

Bypass

 

 

Input

AC/DC

DC/AC

Output

Filter

Boost

Inverter

Filter

 

 

DC/DC

 

Charger

 

Battery

 

Figure 29. Online UPS Block Diagram

Specifications 65

Image 65
Contents Users Guide September 2009 164201789 Table of Contents Dell UPS Management Software RS-232 and USB Communication PortsUPS Status Menu Event Log Menu Testing BatteriesDell Online Rack UPS IntroductionIntroduction What are You Looking For? Find It Here Finding InformationUPS Output Power Safety WarningsSafety Warnings Safety Warnings Inspecting the Equipment InstallationUnpacking the Cabinet Unpacking the CabinetLifting the Cabinet 208V Rear Panel Identifying the UPS Rear Panels230V Rear Panel Dell Online Rack UPS Front Panel Identifying the UPS Front PanelRemoving the Battery Retaining Bracket Rackmount SetupRemoving the Battery Trays Installing the Rails Installing the Cabinet Install the UPS battery trays see Figure Installation Installing the UPS Front Cover Installing the EBMInstalling Remote Emergency Power-off Installing the UPSRepo Connector Repo Connections Wire FunctionHardwiring the UPS Input Circuit Breaker Diagram UPS Initial Startup UPS Input Terminal Block UPS Wiring SpecificationsInstallation Starting the UPS OperationUPS Startup and Shutdown UPS Shutdown Starting the UPS on BatteryControl Button Functions Control Button Sequence Control Panel FunctionsStartup Screen Changing the LanguageDisplay Functions UPS Status Screen LockedBypass Mode Battery ModeBad Battery Detected or Battery Disconnected UPS General Alarms ActiveNormal Mode Status Summary Screens Description Battery Test StatusHigh Efficiency Mode Converter ModeEvent Log Battery Status Screens DescriptionMeasurements Control Screens Description Control ScreensIdentification Settings Description Available Settings Default Setting SettingsSettings Description Available Settings Default Setting Settings Description Available Settings Default Setting Settings Description Available Settings Default Setting Transferring the UPS Between Modes Transferring from Normal to Bypass ModeTransferring from Bypass to Normal Mode Setting Power StrategyBehavior on Overload Retrieving the Event LogControlling Load Segments Through the Display Configuring Load SegmentsConfiguring Automatic Start Delay Configuring Automatic on Battery Shutdown Configuring the UPS for an EBM Configuring Battery SettingsConfiguring Automatic Battery Tests Configuring Automatic RestartRunning Automatic Battery Tests RS-232 and USB Communication Ports Additional UPS FeaturesGND RS-232 Communication Port Pin AssignmentDell Network Management Card Dell Network Management Card OptionalDell UPS Management Software Transporting the UPS UPS MaintenanceUPS and Battery Care Remove the UPS front cover see Figure Storing the UPS and Batteries When to Replace BatteriesUpdating the UPS Firmware Testing BatteriesSpecifications Power Levels Efficiency Normal modeRegulation Normal mode Regulation Battery modeOperating Temperature Environmental and SafetyTemperature Relative Humidity Safety ConformanceBattery Type Battery ConfigurationBattery Runtimes VoltageUPS Status Menu TroubleshootingAccessing Alarms and Conditions Event Log Menu Typical Alarms and ConditionsAction Troubleshooting Troubleshooting Silencing the Alarm
Related manuals
Manual 8 pages 24.59 Kb

H952N, K804N, J739N, K805N, J730N specifications

The Dell J730N, K805N, J739N, 4200W, and 3750W are all high-performance server power supplies designed to provide reliable power solutions for various Dell server models. These power supplies are engineered to ensure maximum uptime, energy efficiency, and seamless operation in data center environments.

Starting with the Dell J730N, this power supply unit is known for its robust design and 730W output capacity. It features hot-swappable functionality, allowing for easy replacement without powering down the server. This is crucial for mission-critical applications where downtime can lead to significant operational challenges. The J730N is compatible with various Dell servers, making it a versatile choice for data centers looking to enhance their power management.

The K805N power supply is another excellent option with a power output of 800W. It incorporates advanced features such as Automatic Voltage Regulation (AVR), which ensures that the output voltage remains stable even during fluctuations in the input voltage. This technology is vital for protecting sensitive server components from potential damage caused by power inconsistencies. Additionally, the K805N is designed with a modular approach, allowing for easy integration and scalability.

The Dell J739N exemplifies Dell’s commitment to energy efficiency with its 750W rating. It meets stringent efficiency standards, making it an environmentally friendly option that helps reduce power consumption and operational costs. The J739N is often used in combination with other Dell equipment to create a cohesive and efficient power management strategy. Its reliability is bolstered by a combination of intelligent internal monitoring systems that detect and address power anomalies.

The 4200W and 3750W power supplies represent higher capacity options for larger, more demanding server environments. These units are equipped with multiple redundant power circuits, ensuring that if one circuit fails, others will continue to supply power without interruption. The advanced cooling technologies utilized in these models also enhance performance and reliability by preventing overheating.

Overall, these Dell power supplies reflect the highest standards in design and technology. They are integral to maintaining the health and efficiency of server operations, contributing significantly to the resilience and effectiveness of data-centered environments. With a focus on compatibility, energy efficiency, and reliability, the J730N, K805N, J739N, 4200W, and 3750W power supplies remain essential components in modern IT infrastructures.