Advanced communications
Pulsar EXtreme C UPSs offer communications solutions and accessories for remote UPS control and monitoring.
Ease of use
Pulsar EXtreme C is only two units high (2U) and fits perfectly in your network or telecom
◗2 communications ports
RS232 | USB |
communications port | communications port |
An RS232 and a USB port are available for easy connection of the UPS to the server. It may be used for:
•personalization of Pulsar EXtreme C by modifying the
•local or remote administration (SNMP/WEB) of the UPS and the protected servers, using
◗Solution-Pac software
•alert users;
•automatically shut down different servers in a heterogeneous environment;
•remotely supervise and control UPSs.
◗Communications slot
Lets you add an SNMP, dry contact, etc. communication card. The cards make UPS communication totally independent. For example, they keep you informed of UPS status when the server is shut down.
◗UPScontrol remote display
Using UPScontrol, the various UPS parameters are remotely displayed.
◗MultiSlot expansion module
This module provides three additional communications slots and concentrates the data from an installation comprising redundant UPSs
bays.
◗Easy installation and integration
• Tower or
• Complete installation kit
Pulsar EXtreme C is supplied with telescopic rails and all the necessary hardware
Flexibility and scalability
Pulsar EXtreme C can adapt easily to all your needs, today and tomorrow.
◗Backup times from 6 minutes to | |
several hours | Users can replace the batteries themselves |
Pulsar EXtreme offers a standard backup | without having to shut down the protected |
time of 6 minutes. | equipment. |
•Quick
•Easy connection to AC power.
◗Comprehensive display and controls
To ensure greater continuity of service, |
it is possible to: |
• connect up to three Pulsar EXB battery |
extension modules to the UPS, without |
interrupting the supply of power to the |
protected applications; |
UPS overload
electronics fault
battery fault
status of programmable outlet no.1
status of programmable outlet no.2
% battery backup time
press and hold to display percent load
lamp test or buzzer off forced transfer to and from bypass
operation on bypass
operation in
operation on battery
ON/OFF
Pulsar EXtreme 1500 C + 3 Pulsar EXB modules for 80 minutes of backup time at full rated load .
•use the CLA module (long
Feel free to contact us for details.
◗Individual management of outlets with PowershareTM
The programmable outlets make it possible to save battery power for the most critical applications. They may also be used to remotely restart or reset a faulty device without interrupting the other protected devices.
◗Warranty and services
Pulsar EXtreme C is covered by a
The optional MGE Warranty+ extension ensures user peace of mind for three years on site.