3.Control and rear panel presentation

1

2

3

6

5

8

7

6

4

4

1> Power on/off switch

2> Indicator Alarm

3> Indicator Battery

4> AC input

5> AC output

6> Circuit breaker

7> Telephone line / modem protection

 

 

8> RS232 port for serial model, USB port for USB model (B type)

4.LED and Audible Alarm operation Table

 

LED Status

Audible Alarm

UPS Status

 

Green ON

None

UPS on normal operation

 

 

 

 

(Power on/off switch)

 

 

 

Green ON

1 beep every 10 seconds

UPS on battery power

 

 

 

 

(Power on/off switch)

 

 

 

Green ON

1 beep every 1 second

UPS on battery power

 

Low battery level

 

 

 

(Power on/off switch)

 

 

 

Red ON

Continuous beep

Internal failure

 

 

 

 

 

 

 

 

Red Blinking

1 beep every 0.5 second

Overload, reduce load

 

 

 

 

 

Red ON

None

Battery fault

 

 

 

Notes:

 

 

1> As soon as the UPS is connected to power, the battery begins charging, whatever the On/Off switch position. When the UPS is operating on battery power, Solution-Pac software will indicate how much time is left at the current level of load. The indicated time remaining is an approximation based on several load-power curves.

2> If the utility power failure exceeds the battery backup time, the UPS will shut down to prevent excessive battery discharge and will restart as soon as utility power returns.

3> After a power outage, when the battery is partially or fully depleted, the indicated time remaining on battery may not be accurate. Always exercise caution when operating your equipment under these circumstances until the batteries have had enough time to completely recharge.

4> The overload breaker trips off during a severe overload. If this occurs, unplug excessive loads and reset circuit breaker by pressing its reset button.

5> Lead-acid batteries operating inside a UPS will last from two to four years before needing replacement, depending on the environment. Before they quit operating entirely, you should contact MGE to order replacement batteries. Doing so will greatly increase the likelihood of protecting your equipment from power black-outs.

6> Do not connect non-computer type loads to NOVA AVR outlets.

MGE UPS SYSTEMS

NOVA AVR User’s Manual / MAU-00026 AA

Page 4

Image 4
Contents Nova 600 AVR Nova 1100 AVR Product Safety Safety of PersonsSpecial Precautions Installation IntroductionLED Status Audible Alarm UPS Status LED and Audible Alarm operation TableControl and rear panel presentation Battery Replacement Disposal of the old batteryPerformance & Product Specifications Trouble ShootingDB-9 cable wiring for serial model Condition Item need to checkSécurité du produit Sécurité des personnesPrécautions particulières Déballage et mise en place Voyants Alarme sonore Fonctionnement de l’ASI PrésentationUtilisation NotaRemplacement des batteries Mise au rebut des batteriesCaractéristiques techniques DépannageCâblage du cordon DB-9 pour le modèle série Symptôme RemèdeMGE UPS Systems Contact MGE

Nova 600 AVR, Nova 1100 AVR specifications

MGE UPS Systems, a renowned name in the uninterruptible power supply (UPS) industry, offers a range of high-quality UPS products designed to protect sensitive electronic equipment from power disturbances. Among its notable offerings are the MGE Nova 1100 AVR and Nova 600 AVR, which are compact and efficient systems tailored for small to medium-sized applications.

The MGE Nova 1100 AVR delivers a robust output capacity of 1100 VA, making it ideal for personal computers, networking devices, and other critical electronics. Meanwhile, the Nova 600 AVR provides 600 VA of power, catering primarily to less demanding devices. Both models feature Automatic Voltage Regulation (AVR), which stabilizes the output voltage and ensures a consistent power supply even when the input voltage fluctuates. This technology enhances the durability of connected devices by mitigating the risks posed by surges and sags in power supply.

One of the key characteristics of the Nova series is their compact design, which allows them to be easily integrated into various environments without occupying excessive space. The user-friendly interface with LED indicators provides real-time status updates, enabling users to monitor battery conditions and load levels effortlessly.

Both the Nova 1100 AVR and 600 AVR come equipped with advanced battery management systems that optimize battery performance and extend lifespan. The systems are designed to smartly manage charging cycles, ensuring that the batteries are always ready for use when needed. The UPS units are also equipped with an overload protection feature that safeguards both the unit and the connected devices from excessive loads.

In terms of connectivity, the Nova series includes multiple outlets that accommodate various plugs, enhancing versatility for users with different equipment needs. Additionally, the systems are designed to minimize acoustic noise, making them suitable for office environments where silent operation is essential.

The installation process for the MGE Nova UPS systems is straightforward, allowing users to set up their units quickly. With a commitment to offering reliable power protection solutions, MGE UPS Systems ensures that its Nova series provides indispensable support for today’s technology-driven world. The combination of AVR technology, compact design, and efficient battery management makes these units a strong choice for individuals and businesses alike looking to safeguard their valuable electronic devices.