6. MAINTENANCE
After installation, the CleanWave→ filter requires almost no maintenance.
We only recommend a periodic (e.g. annual) inspection.
This inspection must be done with no voltage by a qualified technician.
The working sequence is the following :
-Switch off the power of the CleanWave® filter.
-Open the housing in order to access the filter. In the case of the IP21 CleanWave® filter,
-Unscrew and remove the lower part of the front panel (see fig. 3 and 7).
-Check that there is no voltage on the terminals.
-Visually check the general aspect of the filter, especially that there is no excessive dust on the Lo and Zo chokes.
-If necessary, clean the Lo and Zo with compressed air or with a
-Check the tightening of the power terminals.
-Close the housing.
-Power up the filter.
MGE UPS SYSTEMS | CleanWave - Installation and user manual | Page 11/13 |
| Version 2.1 - 21/04/05 - (JME) |
|