APC PRO 1200/1500 manual Operation, Power-Saving Function, Power-Saving Display, Unit sensitivity

Page 3

Operation

Power-Saving Function

To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop computer or an A/V receiver, and Controlled peripheral devices, such as a printer, speakers, or a scanner. When the Master device goes into Sleep or Standby mode, or is switched OFF, the Controlled device(s) will be switched off as well, saving electricity.

Enable the Power-Saving function. Press and hold MUTE and DISPLAY simultaneously for two seconds. The Back-UPS will beep to indicate that the feature is enabled. The leaf icon on the display will illuminate.

Disable the Power-Saving function. Press and hold MUTE and DISPLAY simultaneously for two seconds. The Back-UPS will beep to indicate that the feature is disabled. The leaf icon on the display will darken.

Setting the threshold. The amount of power used by a device in Sleep or Standby mode varies between devices. It may be necessary to adjust the threshold at which the Master outlet signals the Controlled outlets to shut down.

1.Ensure a master device is connected to the Master outlet. Put that device into Sleep or Standby mode, or turn it OFF.

2.Press DISPLAY and MUTE simultaneously and hold for six seconds, until the leaf icon flashes three times and the Back-UPS beeps three times.

3.The Back-UPS will now recognize the threshold level of the Master device and save it as the new threshold setting.

Power-Saving Display

The display interface can be configured to be continuously illuminated, or to save energy, it can be configured to darken after a period of inactivity.

1.Full Time Mode: Press and hold DISPLAY for two seconds. The display will illuminate and the Back-UPS will beep to confirm the Full-Time mode.

2.Power-Saving Mode: Press and hold DISPLAY for two seconds. The display will darken and the Back-UPS will beep to confirm the Power-Saving mode. While in Power-Saving Mode, the display will illuminate if a button is pressed, it then darkens after 60 seconds of no activity.

Unit sensitivity

Adjust the sensitivity of the Back-UPS to control when it will switch to battery power; the higher the sensitivity, the more often the Back-UPS will switch to battery power.

1.Ensure the Back-UPS is connected to utility power, but is OFF.

2.Press and hold the POWER button for six seconds. The LOAD CAPACITY bar will flash on and off, indicating that the Back-UPS is in programming mode.

3.Press POWER again to rotate through the menu options. Stop at selected sensitivity. The Back-UPS will beep to confirm the selection.

Low sensitivity

Medium sensitivity (Default)

High sensitivity

156-300 Vac

176-294 Vac

176-288 Vac

Input voltage is extremely low or high. (Not recommended for computer loads.)

The Back-UPS frequently switches to

The connected equipment is

battery power.

sensitive to voltage fluctuations.

Back-UPS Pro 1200 & 1500 230 V Installation and Operation

3

Image 3
Contents Connect the battery Install PowerChute Personal Edition SoftwareInventory Battery Backup and Surge Protected outlets Connect the equipmentMaster and Controlled outlets Unit sensitivity Power-Saving FunctionPower-Saving Display OperationFront panel Front Panel Buttons and Display InterfaceF01 System FaultsIf these icons are This may be the problem Illuminated Audible WarningsDescription PowerFunction Button Quick-Reference Function Button TimingProblem Possible Cause Corrective Action TroubleshootingWarranty SpecificationsReplacement Battery Service