APC 5000 user manual Glossary, Uninterruptible Power Supply

Page 68

7. Appendices

7.3 Glossary

Backup time

Time that the connected loads can operate on battery power.

Bypass AC source

Source supplying the bypass line. The load can be transferred to the bypass line if an overload

 

occurs on the UPS output, for maintenance or in the event of a malfunction.

ECO mode

Operating mode by which the load is supplied directly by the AC source if it is within the

 

tolerances defined by the user. This mode reduces the consumption of electrical power.

External

Input used to synchronise the UPS to an external signal.

synchronisation port

 

Fin

UPS input frequency (normal or Bypass AC input).

Load

Devices or systems connected to the UPS output.

Normal (double

The normal UPS operating mode in which the AC source supplies the UPS which in turn supplies

conversion) mode

the connected loads (after electronic double conversion).

Normal AC source

Normal source of power for the UPS.

PFC

Sinusoidal input module used to eliminate the harmonics reinjected by the UPS upstream.

Relay contacts

Contacts supplying information to the user in the form of signals.

Uin

UPS input voltage (normal or Bypass AC input).

Uout

UPS output voltage.

UPS

Uninterruptible Power Supply.

3400181300/AE

Image 68
Contents Mgetm GalaxyTM Introduction Safety Safety rulesSafety of persons Product safetyDocumentDisplay ForewordPictograms Contents Assembly and connection of an empty battery cabinet OperationContents Mgetm GalaxyTM UPS cabinet External battery cabinet / auxiliary cabinetPresentation Simplified diagram of power connections Inside the UPS cabinet, access to connectionsExample of version with built-in battery Cabinet layout normal or false floor View with terminal-block protection cover removedUser-machine interface Relay communication cardInstallation UPS cabinet Battery cabinetLocation Layout of cabinetsUPS External battery cabinetRemoving the cardboard protecting the batteries Required protective devices and cable sizes Recommended upstream protectionRecommended downstream protection Earth-leakage currentBattery/terminal Required cable sizesMinimum sizes Rating Separate Normal AC Separate Bypass For commonGalaxy TNS upstream and TNS downstream installation 2.5 System earthing arrangementsWith differential circuit breaker Without differential circuit breakerInstallation with upstream IT and downstream TNS TNC upstream, TNS downstreamFrequency converter without Bypass AC input Upstream and downstream Neutral not distributedInstallation Q3BP Q4S Connection of power cables in a single UPS unit Interconnecting the cabinet earthsUPS units with common normal and Bypass AC inputs UPS units with separate normal and Bypass AC inputsConnect the usage cable PEN to the UPS earthing terminal Connection of earth cable and tying of cables Connection of power cables for parallel UPS unitsEquipotential bonding between parallel-connected units This configuration does not have an external bypass To load Normal SourceConnection of the 150 kVA external bypass cabinet KeyConnection of the 360 kVA external bypass cabinet Connection of the 600 kVA external bypass cabinet Exchange-current interconnections Can // interconnectionsExternal bypass cabinet Jumpers connected to Aux. terminal blockExternal bypass cabinet Interconnections with the external bypass cabinetXMB 08 XMB Connection of the relay communications card Characteristics of the output contacts Characteristics of the input contactsCommunications card connection example Adding communication cardsCable description Insulation level Location on illustration Running the control/communications cablesSingle UPS Parallel UPS Mounting the battery circuit breaker kit Power connections for an external battery cabinetAssembly and connection of an empty battery cabinet Mounting the shelves and the battery cells Control connections for an external battery cabinet Connection of an input isolating transformer Connection of an output isolating transformerOperation Shutting down a single UPSRestarting a single UPS Load is protected by the UPS 31 32Load is protected by the UPSs Shutting down a parallel configurationRestarting a parallel configuration Operation of mimic-panel LEDs Single UPS start sequence on Normal AC inputNormal double conversion mode ECO mode single UPS onlyOperating modes Bypass AC source availableLoad on battery power Transfer to battery powerEnd of battery power Access to the personalisation functionsOperating mode BatteryFrequency Automatic bypassRelay contacts communications card Inputs Factory setting Options available on all contactsOutputs Factory setting Options available on all contacts Display functions Welcome screenMaintenance Identification of alarmsLife Cycle Monitoring LCM LED Buzzer SignificationUPS operating in ECO mode UPS isolationFrequency converter If supplied by the network via the Bypass AC channelShutdown and isolation of the second UPS unit Parallel UPS configuration without external bypass cabinetShutdown and isolation of the first UPS unit Shutdown and isolation of all the UPS units Parallel UPS configuration with external bypass cabinetShutdown and isolation of one UPS unit Return to the normal position UPS unit starts automatically LED 31 is onUPS restarts and LED 31 is on Restart the UPS unit for which all switches are set to OFFUPS unit starts automatically. LED 31 is on Parallel UPS configuration with external bypass cabinet Training centres Environment SubstancesPacking End of lifeAvailable options Appendices Technical sheetsCenter of gravity Tip angle to the rearElectrical characteristics Selection of protection devicesUPS unit with common normal and Bypass AC inputs UPS unit with separate normal and Bypass AC inputsInput / output characteristics Line current valuesWith external bypass cabinet Maximum allowable power for parallel UPS unitsWithout external bypass cabinet Thermal characteristics UPS power rating Heat losses Recommended air ThroughputRestrictions to parallel operation Single UPS Parallel UPSGeneral characteristics of Mgetm GalaxyTM 5000 UPSs UPS power in kVA 100 120 Normal AC inputBypass AC input InverterUPS power in kVA 100 120 UPS componentsIP32 installation OptionsUninterruptible Power Supply Glossary

5000 specifications

The APC 5000 series is a comprehensive power protection solution designed for various applications, leveraging advanced technology to ensure reliable performance. Engineered by APC by Schneider Electric, a leader in power management and surge protection, the APC 5000 series is the ideal choice for businesses and home offices alike.

One of the standout features of the APC 5000 is its exceptional power conditioning capabilities. This series includes advanced Automatic Voltage Regulation (AVR) technology, which maintains consistent voltage levels and protects connected devices from power fluctuations and outages. This ensures that sensitive equipment, such as computers and networking hardware, receive stable power for optimal performance.

The APC 5000 series integrates a robust surge protection mechanism that guards against sudden voltage spikes, a common issue in areas prone to electrical disturbances. This protection is crucial for safeguarding devices from potentially damaging surges caused by lightning strikes or power inconsistencies.

Another notable characteristic is the impressive battery backup system. The integrated high-capacity battery provides sufficient runtime during power outages, allowing users to save their work and shut down devices safely. This feature is vital for preventing data loss in critical situations and lends peace of mind for users who rely heavily on electronic equipment.

The UPS (Uninterruptible Power Supply) system in the APC 5000 is equipped with LCD display panels that provide real-time information on power conditions. Users can easily monitor load levels, battery status, and voltage output, which aids in proactive management and enhances overall operational efficiency.

Moreover, the APC 5000 series features multiple output options including USB and serial connectivity, making it compatible with various devices. Its compact design allows for easy integration into different environments, from small office setups to larger enterprise configurations.

In summary, the APC 5000 series is a versatile power protection solution characterized by its AVR technology, robust surge protection, reliable battery backup, real-time monitoring features, and compatibility with multiple devices. Whether for business or personal use, the APC 5000 series stands out as a reliable partner in ensuring uninterrupted power and protecting valuable electronic equipment.