APC 3000 installation manual Input/Output Wiring Dual Mains, Wiring procedure dual mains

Page 42

Input/Output Wiring – Dual Mains

The UPS is designed for single mains installation as default. Carry out the Total Power Off Procedure, and follow the below instructions to install the UPS in a dual-mains installation

The illustrations show 20.59in/523mm Enclosures, but the installation procedures are identical for 13.85in/352mm Enclosures).

Wiring procedure - dual mains



C

N B N

N

Conduit box

 

 



 

 



 

 

(top part)

 

 

 

 

 

 

 



 

 

 

 



Conduit box





 

 

(bottom part)

 

 

 

 

 

 

Bypass

Output

Input

 

 

MBP Conduit

 

 



A

Conduit box (top part)



EPO Conduit

Loosen the (6) M4x13 screws from the plate covering the cable termination area, and remove.

Loosen the (2) M4x13 screws from the top part of the Conduit Box. Loosen the 3 M4x13 attaching it to the bottom part (2 screws in a 13.85in/352mm Enclosure) and remove.

Loosen the (4) M4x13 screws (2 each side) from the bottom part of the Conduit Box and remove.

34

AIS® 3000 10-30kVA, 208V, Site Preparation and Installation Manual – 990-1957

Image 42
Contents AIS Page AIS 3000 10-30kVA Page Contents Electrical Installation General Charge Setting Page Introduction General Safety Instructions Environmental symbolsUPS Family Range and Components 13.85in/352mm Enclosures20.59in/523mm Enclosures V T 1 0 K F 1 B 2 S Part number codingBattery Module Conduit BoxFront Panel overview Stabilizing Bracket User interface XR Enclosure weights OptionsBattery Module Part Number for Battery ModuleBattery Module weight Part Numbers for XR EnclosuresFloor anchoring and battery securing equipment Installation Space Requirements Clearance for 20.59in/523mm EnclosuresSpace requirements Site Preparation UPS and XR Installation Space Requirements Clearance for stand-alone 13.85in/352mm Enclosures Space requirements Floor Anchoring Preparation Drilling floor holes for floor anchoringHole positions for floor anchors stand-alone Enclosures Site Preparation UPS and XR Floor Anchoring Preparation Heat dissipation Operating EnvironmentOperating conditions Audible noiseRecommended source connections Recommended current protection Dual/singleMinimum setting of breakers for 10kVA UPS Minimum setting of breakers for 15kVA UPSOverload Mains input Bypass input Output Duration Event Minimum setting of breakers for 20kVA UPS Minimum setting of breakers for 30kVA UPSEPO switch wiring Basic Wiring Overview Site Preparation Checklist System components. Have youFront Panel RemovalInstallation Total-Power-Off Procedure Electrical Installation Total-Power-Off Procedure System-Electrical Information UPS ratingsSource connections Wiring Input/Output Wiring Single Mains default Wiring procedure single mainsCables Output Input/Output Wiring Dual Mains Wiring procedure dual mainsElectrical Installation Input/Output Wiring Dual Mains Communication Wiring to EPO and Optional Equipment Pin connections J106 XR Enclosure and J108 EPO Pin connections J106 UPS to J200 XR Enclosure optionXR Enclosure, APC MBP, and Generator Control wiring Pin connections J108 for EPO wiring options General Charge Setting Charge setting procedureSetting the leveling feet Leveling FeetFloor Anchoring option Floor anchoring of stand-alone systemsBattery securing Wiring Verification Procedure Bypass Input for dual mains installationsElectrical Installation Wiring Verification Procedure Installation Site Checklist Terms of warranty APC product coveredAssignment of warranties Warranty claims procedure Drawings, descriptionsExclusions Electrical Installation Limited Factory Warranty 990-1957
Related manuals
Manual 8 pages 29.77 Kb Manual 21 pages 12.14 Kb Manual 2 pages 10.71 Kb

3000 specifications

The APC 3000 and 4000 series are advanced uninterruptible power supply (UPS) systems designed to provide reliable and efficient power protection for a variety of applications. These systems play a crucial role in safeguarding sensitive electronic equipment from power disturbances, including surges, sags, and complete power outages.

Both the APC 3000 and 4000 models come equipped with a robust set of features engineered to improve performance and optimize energy efficiency. One notable characteristic is their sine wave output, which ensures smooth and dependable power delivery, essential for maintaining the proper functionality of connected devices.

Key technologies integrated into these models include advanced battery management systems that extend the life of the batteries and enhance overall performance. The UPS units utilize high-frequency technology, which minimizes the size and weight of the system while maximizing output power. This enables both the APC 3000 and 4000 to fit seamlessly into various environments, from data centers to small offices.

In addition to their compact design, the APC 3000 and 4000 series feature easy-to-read LCD displays providing real-time information on critical parameters such as battery status, load level, and remaining runtime. This feature allows users to monitor performance and make informed decisions about power management effortlessly.

Another vital aspect of the APC 3000 and 4000 series is their expansion capabilities. Both models offer additional battery packs, allowing users to increase runtime as needed. These UPS systems also support hot-swappable batteries, making maintenance quick and efficient, minimizing downtime during service and repairs.

Furthermore, APC’s PowerChute software is compatible with the 3000 and 4000 series, allowing for easy management of power settings and the ability to configure user-defined power settings. This software also enables users to receive alerts for system status issues and performs scheduled shutdowns, ensuring data integrity during power failures.

Overall, the APC 3000 and 4000 series offer a combination of performance, reliability, and user-friendliness. These UPS systems are ideal choices for protecting critical electronic equipment and ensuring uninterrupted operations in various environments. Users looking for a dependable power solution will find that these models exceed expectations with their advanced features and robust technologies.