Agilent Technologies N3970A manual Getting Started and Turning on

Page 14

GETTING STARTED AND TURNING ON

This and following sections show you how to use your instrument:

Check that the correct accessories have been supplied, and an optical connector adaptor has been fitted. If you have any queries, call your supplier to resolve the situation.

Put in the batteries, or plug external power into the socket at the top of the instrument (see Battery and External Power section).

Push the green POWER button. The display will come on. If the battery is low, this will be indicated on the display. Pushing POWER again will turn the instrument off.

To stop the instrument turning off 10 minutes after the last key press, hold POWER down for 3 seconds during turn-on. PERM on the display indicates that the unit will stay on permanently.

To back light the display temporarily, select LIGHT. To back light continuously, hold down the button for 3 seconds. Use of the back light will drain the batteries faster.

This instrument uses a menu driven keypad. The function of each button is shown on the display.

To access the optical connector, grasp a top corner of the instrument, and pull off the cover. The connector can be swivelled to improve access.

After instrument turn on, the instrument will perform a self- calibration sequence, set the dark current adjustment, and then display absolute power in dBm at the previously set λ. If HI or LO are displayed, the input is out of range.

The hidden keypad is accessed by pulling up the hinged display cover. The hidden keypad can operate in two modes. The second mode is accessed by SHIFT. Access to the second mode can be denied / permitted by typing the button sequence

:POWER (turn on instrument), SHIFT, CANCEL, SET, SELECT, RECALL, STORE.

N3970A UM-1

11

Image 14
Contents Operating Maintenance Guide Page Select POWER, Source, then Autotest Push Autotest on source and wait a few secondsN3970A Introduction and ApplicationsContents Service and Support Introduction and Applications Typical applications Safety Summary 10149 Battery and External Power Optical Connector Cleaning Bare fiber adaptorsGetting Started and Turning on Getting Started and Turning on Operation General Autotest featuresAutotest Operation Either a ‘local’ or ‘remote’ reference can be stored Power Meter Operation Memory No Storing & recalling readings using non-volatile memoryStoring & Recalling Readings Total memory 845Memory operating sequence SET, StoreLocal / remote modes Wire 1 screenRS232 Interface Care of Your Instrument Accuracy Considerations All measurementsAccuracy Considerations Calibration & Maintenance Maintenance Opening the instrumentCALIBRATION, Maintenance & Instrument Returns Conditions during the spectral responsivity calibration Total UncertaintySpecifications & Ordering Information Size WeightPower Operating / storageOptional accessories Agilent Part No Description Standard accessoriesAgilent service Part No Description InstrumentPerformance Test Equipment Required81654A 81657A or 1550±30nm Test Record Performance Test Configure the optical head and interface module Connect the attenuator output cable to the DUT as Performance Test Accessories #Product Description Model No Trace No Cal. Due DateTest Wavelengths = 1300 nm and 1310 nm Test Wavelengths = 1550 nm Cleaning Information Safety PrecautionsWhy is it important to clean optical devices ? Procedure for Stubborn Dirt Cleaning ProceduresPreferred Procedure Disclaimer & Warranty N3970A UM-1

N3970A specifications

Agilent Technologies N3970A, a versatile signal generator, represents a significant advancement in the realm of electronic testing and measurement. Designed for engineers and researchers, this compact instrument is particularly suited for applications in automotive, wireless communications, and manufacturing sectors.

One of the standout features of the N3970A is its frequency range, extending from 10 MHz to 3 GHz. This broad frequency coverage allows users to address a wide spectrum of testing requirements, making it a valuable tool for various applications. The instrument supports different modulation formats, including AM, FM, and PM, which further enhances its usability across diverse test scenarios.

The N3970A is equipped with Agilent's proprietary technologies that ensure high performance and precision. Its phase noise specifications are impressive, contributing to the generation of clean signals. This characteristic is crucial when conducting tests on sensitive components or systems that demand low phase noise to achieve accurate results.

Another important feature is the N3970A's intuitive user interface. The instrument is designed with a clear LCD display and straightforward controls, ensuring that users can easily navigate through its multitude of functions. This user-centric design minimizes the learning curve, enabling engineers to focus on their testing rather than troubleshooting the equipment.

The instrument also boasts advanced calibration capabilities. With built-in self-calibration functions, users can maintain the accuracy of the N3970A over time, ensuring consistent performance in any testing environment. This feature is particularly critical in production settings where precision is key to delivering quality products.

Moreover, the N3970A supports automation through remote programming, which can be executed via various communication protocols. This capability enables users to integrate the signal generator into automated test systems, facilitating more efficient testing processes.

Overall, Agilent Technologies N3970A stands out as a reliable and efficient signal generator, blending advanced technology with user-friendly features. Whether utilized in the laboratory or on the manufacturing floor, this instrument is designed to meet the demands of modern electronic testing, providing engineers with the tools necessary to innovate and excel in their respective fields. Its combination of performance, versatility, and ease of use establishes it as an essential asset for professionals in the electronics domain.