CLEANING INFORMATION

The following Cleaning Instructions contain some general safety precautions, which must be observed during all phases of cleaning. Consult your specific optical device manuals or guides for full information on safety matters.

Please try, whenever possible, to use physically contacting connectors, and dry connections.

Clean the connectors, interfaces, and bushings carefully after use.

If you are unsure of the correct cleaning procedure for your optical device, we recommend that you first try cleaning a dummy or test device.

Agilent Technologies assume no liability for the customer's failure to comply with these requirements.

For more information about Cleaning Instruments, please consult the Pocket Guide "Cleaning Procedures for Lightwave Test and Measurement Equipment" (Agilent P/N 5963-3538F). If you do not have a copy of this pocket guide, Agilent will provide you with one free of charge.

Safety Precautions

Please follow the following safety rules.

Do not remove instrument covers when operating.

Ensure that the instrument is switched off throughout the cleaning procedures.

Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.

Make sure that you disable all sources when you are cleaning any optical interfaces.

Under no circumstances look into the end of an optical device attached to optical outputs when the device is operational. The laser radiation is not visible to the human eye, but it can seriously damage your eyesight.

To prevent electrical shock, disconnect the instrument from the mains before cleaning. Use a dry cloth, or one slightly

N3970A UM-1

39

Image 42
Contents Operating Maintenance Guide Page Select POWER, Source, then Autotest Push Autotest on source and wait a few secondsN3970A Introduction and ApplicationsContents Service and Support Introduction and Applications Typical applications Safety Summary 10149 Battery and External Power Optical Connector Cleaning Bare fiber adaptorsGetting Started and Turning on Getting Started and Turning on General Autotest features Autotest OperationOperation Either a ‘local’ or ‘remote’ reference can be stored Power Meter Operation Memory No Storing & recalling readings using non-volatile memoryStoring & Recalling Readings Total memory 845Memory operating sequence SET, StoreWire 1 screen RS232 InterfaceLocal / remote modes Care of Your Instrument Accuracy Considerations All measurementsAccuracy Considerations Calibration & Maintenance Maintenance Opening the instrumentCALIBRATION, Maintenance & Instrument Returns Conditions during the spectral responsivity calibration Total UncertaintySpecifications & Ordering Information Size WeightPower Operating / storageOptional accessories Agilent Part No Description Standard accessoriesAgilent service Part No Description InstrumentPerformance Test Equipment Required81654A 81657A or 1550±30nm Test Record Performance Test Configure the optical head and interface module Connect the attenuator output cable to the DUT as Performance Test Accessories #Product Description Model No Trace No Cal. Due DateTest Wavelengths = 1300 nm and 1310 nm Test Wavelengths = 1550 nm Cleaning Information Safety PrecautionsWhy is it important to clean optical devices ? Cleaning Procedures Preferred ProcedureProcedure for Stubborn Dirt Disclaimer & Warranty N3970A UM-1

N3970A specifications

Agilent Technologies N3970A, a versatile signal generator, represents a significant advancement in the realm of electronic testing and measurement. Designed for engineers and researchers, this compact instrument is particularly suited for applications in automotive, wireless communications, and manufacturing sectors.

One of the standout features of the N3970A is its frequency range, extending from 10 MHz to 3 GHz. This broad frequency coverage allows users to address a wide spectrum of testing requirements, making it a valuable tool for various applications. The instrument supports different modulation formats, including AM, FM, and PM, which further enhances its usability across diverse test scenarios.

The N3970A is equipped with Agilent's proprietary technologies that ensure high performance and precision. Its phase noise specifications are impressive, contributing to the generation of clean signals. This characteristic is crucial when conducting tests on sensitive components or systems that demand low phase noise to achieve accurate results.

Another important feature is the N3970A's intuitive user interface. The instrument is designed with a clear LCD display and straightforward controls, ensuring that users can easily navigate through its multitude of functions. This user-centric design minimizes the learning curve, enabling engineers to focus on their testing rather than troubleshooting the equipment.

The instrument also boasts advanced calibration capabilities. With built-in self-calibration functions, users can maintain the accuracy of the N3970A over time, ensuring consistent performance in any testing environment. This feature is particularly critical in production settings where precision is key to delivering quality products.

Moreover, the N3970A supports automation through remote programming, which can be executed via various communication protocols. This capability enables users to integrate the signal generator into automated test systems, facilitating more efficient testing processes.

Overall, Agilent Technologies N3970A stands out as a reliable and efficient signal generator, blending advanced technology with user-friendly features. Whether utilized in the laboratory or on the manufacturing floor, this instrument is designed to meet the demands of modern electronic testing, providing engineers with the tools necessary to innovate and excel in their respective fields. Its combination of performance, versatility, and ease of use establishes it as an essential asset for professionals in the electronics domain.