Agilent Technologies 60501B, 60502B Signal-Name Descriptions Mnemonic Function Sheet, Power Board

Page 34

Table 4-2. Signal-Name Descriptions

Mnemonic

 

Function

 

Sheet 1

Sheet 2

Sheet 3

 

 

POWER BOARD

 

 

 

ACLR*

 

Analog circuits clear (D)

 

1A, 7B

 

 

 

 

 

 

BO*

 

Brown out input disable (D)

 

1A, 2B, 8B

 

 

+BUS

 

+ input binding post

 

 

4A

 

- BUS

 

- input binding post

 

 

4A

 

CC_PROG

 

Programming voltage for CC mode (A)

8C, 4C

 

 

CR*

 

CR_mode low range select (D)

 

8B

 

 

CV_PROG

 

Programming voltage for CV mode (A)

8D

 

 

E2

 

Electrical connection

 

8A, 6B

 

 

E8

 

Electrical connection

 

6A, 7D

 

 

E11

 

Electrical connection

 

5A, 8D

 

 

IMON*

 

Input-current monitor signal (A)

 

8B

7A

 

+IN

 

+input (A)

 

8A,7A,6D,l

4A

 

 

 

 

 

D,lC

4A

 

- IN

 

- input (A)

 

8A, 7A, 1D

 

+ IN Local

 

Same as + input (A)

 

1D

4A

 

+ OP

 

Overpower comparator input (A) (low = OP)

3A, 8A

 

 

- OP

 

Overpower comparator input (A) (high = OP)

4A, 8A

 

 

OP*

 

Overpower status (D)

 

8A

 

 

+OV

 

Overvoltage comparator input (A) (low = OV)

4D, 8B

 

 

OV*

 

Overvoltage status (D)

 

8B

 

 

PROG

 

Programming input to power circuits (A)

5D, 1C, 7B

8D

 

 

 

Overvoltage reference (A)

 

8B

 

 

RNG

 

CC-mode range select (D)

 

8C

 

 

R268-6

 

Resistor pin number

 

4B, 5D

 

 

R268-8

 

Resistor pin number

 

4B, 5D

 

 

R267-2

 

Resistor pin number

 

4C, 8D

 

 

R267-3

 

Resistor pin number

 

4C, 8C

 

 

R267-10

 

Resistor pin number

 

4C, 6B

 

 

+S

 

Remote + sense (A) (from rear-panel +S)

1D

 

 

- S

 

Remote - sense (A) (from rear-panel - S)

1D

 

 

SPCLR*

 

Secondary-circuit power-on clear (D)

1B

 

 

TEMP1

 

Power-board temperature (A)

 

1B

8A

 

TURNON

 

Power-on input disable (D)

 

8C

 

UNREG

 

Input to unregulated-input comparator (A)

8C, 4C

2C

 

UNREG*

 

Unregulated-input status (D)

 

8A

 

 

VMON*

 

Input-voltage monitor signal (A)

 

8D

 

 

VOFF

 

Voltage off

 

5D

2B

 

+12V_REF

 

Reference for overvoltage circuit (A)

1C

 

 

(A) = analog signal

 

(D) = digital signal

8C = signal origin

 

 

34

Image 34
Contents Electronic Load Modules Certification Safety Summary Table of Contents About This Manual Troubleshooting PrecautionsManual Revisions Module Initialization Store calibration constants in EepromIntroduction Test Equipment RequiredCC Mode Test 60501B 60502BCV Mode Test Test Setup BCR Mode Test Check the middle ohms range as follows Press Then Transient Operation and Slew Circuit Test CC Mode Pard Test CC Mode Power LimitPage Performance Test Record Agilent 60501B Load Module Page 1 Test Description Minimum Results Specification UncertaintyPerformance Test Record Agilent 60501B Load Module Page 2 MeasurementPerformance Test Record Agilent 60502B Load Module Page 1 Agilent 60502BPerformance Test Record Agilent 60502B Load Module Page 2 Model Agilent 60502BReference Designators How To Order PartsPart Description Abbreviations Designation Number DescriptionFUSE-SUBMINIATURE .5A Designation Number IC Quad Nand SET/RESET Latch Cmos Model Agilent Part NumberNot Used RESISTOR-NET 10-PIN SIP MULTI-VALUE Model RT2 Agilent 60501B/60502B Mechanical Parts Quantity Description NumberPage Schematic Diagram Notes Schematic DiagramsCommon +5V Mnemonic Function Sheet Signal-Name Descriptions1D, 1C Sheet 1C, 7D 1B, 6D Mnemonic8C,8B Signal-Name Descriptions Mnemonic Function Sheet Power BoardPage Page Page Page Page Page
Related manuals
Manual 11 pages 42.07 Kb Manual 11 pages 45.05 Kb

60501B, 60502B specifications

Agilent Technologies 60502B is a high-performance signal generator designed for a wide range of applications, including aerospace, telecommunications, and research and development. As part of Agilent's advanced suite of test and measurement solutions, the 60502B provides users with the capability to generate high-quality signals with exceptional accuracy and stability.

One of the standout features of the Agilent 60502B is its frequency range, which spans from 9 kHz to 6 GHz. This broad range enables engineers and technicians to work with various modulation formats and signal types, making it highly versatile for testing and development. The generator supports continuous wave (CW) signals as well as complex modulated signals, accommodating both narrowband and broadband applications.

The 60502B employs advanced direct digital synthesis (DDS) technology, ensuring accurate frequency generation with low phase noise. This technology is essential for applications that require high precision and minimal signal distortion, such as radar and communication systems. The generator’s phase noise performance is exceptional, which enhances its capability for demanding applications requiring signal integrity.

Another key characteristic of the Agilent 60502B is its output power handling. It can deliver output levels ranging from -130 dBm up to +10 dBm, enabling users to drive various loads and achieve optimal testing conditions. This flexibility is particularly beneficial in laboratory environments where different power levels are needed for different devices under test.

The user interface of the 60502B is designed for efficiency and ease of use. It incorporates a large display that provides real-time feedback on settings and signal characteristics, facilitating quick adjustments during testing. Furthermore, the generator is equipped with USB and GPIB interfaces, enabling seamless integration into automated test systems and easy connectivity to computers for remote control and data logging.

In addition to its robust hardware features, the Agilent 60502B supports a variety of modulation schemes, including AM, FM, PM, and pulse modulation. This capability allows users to simulate real-world signals and assess the performance of receivers and other components under various conditions.

Overall, the Agilent Technologies 60502B signal generator stands out in terms of performance, versatility, and user-friendliness. Its wide frequency range, advanced DDS technology, significant power output capabilities, and support for multiple modulation types make it an indispensable tool for engineers across various industries engaged in testing and development activities. Whether for research projects or routine maintenance tasks, the 60502B is built to deliver reliable and precise results.