Operation | IrDA Printer |
Set-Up Mode
The printer has been set up at the factory with the following default parameters:
Baud rate | : 9600 bps |
Handshaking | : DTR |
Country | : U.S.A. |
Print mode | : Text (upright) |
Paper | : Normal paper |
Density | : 100% |
IrDA | : |
If necessary, the default parameters can be changed as follows:
1.With the printer initially switched OFF, press and hold down the SEL pushbutton, and then switch ON the printer.
2.The printer now goes into its
Note: If no button is pressed within 15 seconds, the
3.Baud rate is the first parameter printed. Pressing the FEED button causes the value of that parameter to change in the sequence shown in the following table.
SEL Button |
| FEED Button |
| ||
|
|
|
Baud rate |
| 115200, 57600, 38400, 19200, 9600, 4800, 2400, |
Handshaking |
| 1200, 600, 300 |
| DTR, | |
Country |
| U.S.A., Turkish, Denmark2, Norway, Japan, Spain, |
Print mode |
| Italy, Sweden, Denmark1, U.K., Germany, France |
| Text(upright), Data(inverted) | |
Paper |
| Normal paper, Reprint paper |
Density |
| 50 – 150% in 5% steps |
IrDA |
|
6 | Instruction |