Bacharach Infrared Printer manual Set-Up Mode, SEL Button Feed Button

Page 10

Operation

IrDA Printer

Set-Up Mode

The printer has been set up at the factory with the following default parameters:

Baud rate

: 9600 bps

Handshaking

: DTR

Country

: U.S.A.

Print mode

: Text (upright)

Paper

: Normal paper

Density

: 100%

IrDA

: IrDA-SIR

If necessary, the default parameters can be changed as follows:

1.With the printer initially switched OFF, press and hold down the SEL pushbutton, and then switch ON the printer.

2.The printer now goes into its set-up mode as indicated by the red LED flashing. At this time all of the printer’s current parameter settings are printed, followed by the first parameter that can be modified.

Note: If no button is pressed within 15 seconds, the set-up mode is automatically terminated without changing the original parameters.

3.Baud rate is the first parameter printed. Pressing the FEED button causes the value of that parameter to change in the sequence shown in the following table.

SEL Button

 

FEED Button

 

 

 

 

Baud rate

 

115200, 57600, 38400, 19200, 9600, 4800, 2400,

Handshaking

 

1200, 600, 300

 

DTR, X-on/X-off

Country

 

U.S.A., Turkish, Denmark2, Norway, Japan, Spain,

Print mode

 

Italy, Sweden, Denmark1, U.K., Germany, France

 

Text(upright), Data(inverted)

Paper

 

Normal paper, Reprint paper

Density

 

50 – 150% in 5% steps

IrDA

 

HP-Ir, IrDA-Sir

6

Instruction 24-9450

Image 10
Contents Portable Wireless Infrared Printer Warranty Contents IrDA Printer Description FeaturesGeneral Pushbuttons Power SwitchIndicator LEDs SensorsComponent Locations and Functions Technical Characteristics Operation PrecautionsSelf Test Set-Up Mode SEL Button Feed ButtonUsing the Printer Using the PrinterBattery Installation MaintenancePaper Installation Maintenance Cleaning the Printer Cleaning the Print HeadReplacement Parts Parts & ServiceService Centers Headquarters Hunt Valley Circle, New Kensington, PA