Bryant Discover the Combination Ratings for FV4BNB006 and FY4ANB060 Air Conditioner Models

Models: 123A

1 38
Download 38 pages 44.17 Kb
Page 27
Image 27

COMBINATION RATINGS CONTINUED

AHRI Ref. No.

Model Number

Indoor Model

Furnace Model

3124428

123AEA060---C

CNPV*6024A**

353AAV060120

3047227

123AEA060---C

CNPV*6024A**+TDR

 

3047248

123AEA060---C

CSPH*6012A**

313*AV048090

3047249

123AEA060---C

CSPH*6012A**

313*AV060110

3047250

123AEA060---C

CSPH*6012A**

313*AV060135

3047234

123AEA060---C

CSPH*6012A**

315(A,J)AV060110

3047235

123AEA060---C

CSPH*6012A**

315(A,J)AV066135

3047236

123AEA060---C

CSPH*6012A**

315(A,J)AV066155

3124432

123AEA060---C

CSPH*6012A**

353AAV048080

3124433

123AEA060---C

CSPH*6012A**

353AAV060100

3124434

123AEA060---C

CSPH*6012A**

353AAV060120

3047233

123AEA060---C

CSPH*6012A**+TDR

 

3047238

123AEA060---C

FE4ANB006+UI

 

3047239

123AEA060---C

FV4BNB006

 

3047237

123AEA060---C

FX4CN(B,F)060

 

3047240

123AEA060---C

FY4ANB060

 

Capacity

56000

57000

56000

56500

56000

55500

55500

55500

55500

56000

56000

56500

57000

57000

58000

56500

EER

SEER

Phase

11.20

13.50

3

11.00

13.00

3

11.00

13.00

3

11.50

13.50

3

11.00

13.00

3

11.00

13.20

3

11.20

13.50

3

11.20

13.50

3

11.00

13.20

3

11.20

13.20

3

11.20

13.50

3

11.00

13.00

3

11.20

13.50

3

11.20

13.50

3

11.00

13.20

3

11.00

13.00

3

*Tested combination .

NOTES:

1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.

2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures.

3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.

4. Do not apply with capillary tube coils as performance and reliability are significantly affected. EER — Energy Efficiency Ratio

SEER — Seasonal Energy Efficiency Ratio

TDR — Time---Delay Relay. In most cases, only one method should be used to achieve TDR function. Using more than one method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay, KAATD0101TDR, or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.

TXV — Thermostatic Expansion Valve

123A

27

Page 27
Image 27
Bryant manual 3047239 123AEA060---C

123A specifications

Bryant 123A is a high-efficiency residential air conditioning unit that stands out for its reliable performance and advanced features. Designed with homeowners in mind, this model combines modern technology with user-friendly functionality, ensuring optimal comfort in various climates.

One of the main features of the Bryant 123A is its variable-speed compressor, which allows for precise temperature control and energy savings. Unlike traditional units that operate at a fixed speed, the variable-speed compressor adjusts its output based on the cooling needs of the home. This not only maintains a more consistent indoor temperature but also reduces energy consumption, making it an environmentally friendly choice.

The unit also boasts a SEER (Seasonal Energy Efficiency Ratio) rating of up to 19. This high rating means that the Bryant 123A operates with exceptional energy efficiency, translating into lower utility bills. Homeowners will appreciate the long-term savings that come with this energy-efficient design.

In addition to its impressive efficiency, the Bryant 123A features a robust construction designed to withstand various weather conditions. The steel cabinet is both durable and corrosion-resistant, ensuring that the unit will endure over time. Furthermore, the unit is equipped with a sound-dampening system that minimizes operational noise, providing a quieter indoor environment.

Smart technology integration is another significant characteristic of the Bryant 123A. Homeowners can benefit from the optional Ecobee Smart Thermostat compatibility, allowing remote access and control of the cooling system through smartphone apps. This feature enables users to adjust settings from anywhere, enhancing convenience and energy management.

Moreover, the Bryant 123A utilizes eco-friendly refrigerant, further solidifying its commitment to sustainable practices. The R-410A refrigerant is not only effective at cooling but also contributes to lower ozone depletion potential. This choice aligns with modern environmental standards and regulations, making the unit a responsible choice for conscious consumers.

Overall, the Bryant 123A unit is a standout option for residential air conditioning, offering advanced features, high efficiency, and durable construction. Whether for new installations or replacements, this model promises to deliver reliable cooling performance while maximizing cost savings and environmental responsibility. Homeowners seeking comfort without compromise will find the Bryant 123A an ideal solution for their cooling needs.