3

PHYSICAL DATA

UNIT SIZE --- SERIES 018 --- C 024 --- C 030 --- C 036 --- C 042 --- C 048 --- C 060 --- C
Operating Weight lb (kg) 130
(59.0)
130
(59.0)
142
(64.4)
161
(73.0)
205
(93.0)
228
(103.4)
251
(113.9)
Shipping Weight lb (kg) 151
(68.5)
151
(68.5
164
(74.4)
184
(83.5)
233
(105.7)
256
(116.1)
285
(129.3)
Compressor Type Scroll
REFRIGERANT Puron®(R---410A)
Control TXV (Puron®Hard Shutoff)
Charge lb (kg) 3.57
(1.62)
3.72
(1.69)
4.50
(2.04)
5.05
(2.29)
5.84
(2.65)
8.00
(3.63)
8.44
(3.83)
COND FAN Propeller Type, Direct Drive
Air Discharge Vertical
Air Qty (CFM) 1880 2200 2200 2950 3170 3365 4050
Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/4
Motor RPM 1100 1100 1100 1100 825 825 825
COND COIL
Face Area (Sq. ft.) 9.85 9.85 11.49 14.77 17.25 21.56 25.15
Fins per In. 20 20 25 25 25 25 25
Rows 1 1 1 1 1 1 1
Circuits 3 3 3 3 4 5 5
VALVECONNECT.(In.ID)
Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8
Liquid 3/8
REFRIGERANT TUBES (In. OD)
Rated Vapor* 5/8 5/8 3/4 3/4 7/8 7/8 1 --- 1 / 8
Liquid 3/8
*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS

LONG LINE APPLICATION: An application is considered ”Long

line” when the total equivalent tubing length exceeds 80 ft. (24.38

m) or when there is more than 20 ft. (6.09 m) vertical separation

between indoor and outdoor units. These applications require

additional accessories and system modifications for reliable system

operation. The maximum allowable total equivalent length is up to

250 ft. (76.2 m). The maximum vertical separation is 200 ft.

(60.96 m) when outdoor unit is above indoor unit, and up to 80 ft.

(24.38 m) when the outdoor unit is below the indoor unit. Refer to

Accessory Usage Guideline below for required accessories. See

Longline Application Guideline for required piping and system

modifications. Also, refer to the table below for the vapor tube

diameters based on the total length to minimize the cooling

capacity loss.

Unit Nomi-
nal Size
(Btuh)
Maximum
Liquid Line
Diameters
(In. OD)
Vapor Line
Diameters
(In. OD)
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
Standard
Application Long Line Application Requires Accessories
26 --- 50
(7.9--- 15.2)
51 --- 80
(15.5---24.4)
81 --- 100
(24.7---30.5)
101 --- 125
(30.8---38.1)
126 --- 150
(38.4---45.7)
151 --- 175
(46.0---53.3)
176 --- 200
(53.6---61.0)
201 --- 225
(61.3---68.6)
226 --- 250
(68.9---76.2)
18000
1Stage
Puron AC
3/8 1/2 1234678910
5/8 001112233
24000
1Stage
Puron AC
3/8
5/8 011233445
3/4 000011111
7/8 000000000
30000
1Stage
Puron AC
3/8
5/8 123345678
3/4 001112223
7/8 000011111
36000
1Stage
Puron AC
3/8
5/8 124567910 11
3/4 001122334
7/8 000011112
42000
1Stage
Puron AC
3/8
3/4 012234456
7/8 001112223
11/8 000000000
48000
1Stage
Puron AC
3/8
3/4 012345567
7/8 001122233
11/8 000000011
60000
1Stage
Puron AC
3/8
3/4 124567910 11
7/8 012234455
11/8 000111111
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Applica-
tion Guidelines

123A