TOS-SN-1

Specifications

 

 

 

 

 

Item

Specification

 

Part number

TOS-SN-1

 

Service

Indoors. Altitude of less than 1000m (3280ft)

 

Environment

 

 

 

Must not be exposed to direct sunlight, subject to corrosive

 

 

and/or explosive gases, vapor, dust, chips, cutting oil, grinding

 

 

agent, etc.

 

Ambient

From -100C to+500C (140C to 1040C)

 

Temperature

 

 

Storage

From -250Cto+650C (-120Cto1490C)

 

Temperature

 

 

Relative humidity

20% to 90%

 

 

(no condensation allowed)

 

Vibration

5.9m/s2 or less

 

Cool system

Self-cooling

Protection Functions

 

If you receive an error code while operating the drive from the extended panel, refer to the table below for solutions to resolve the error.

Error Code

Details

Causes and Remedies

гAN.E

RAM error

Reset the extended panel. If the same indication

гON.E

ROM error

appears again after resetting, ask the dealer to

CPU.E

CPU error(watch

investigate the cause

 

dog)

 

 

 

The error status will automatically be cancelled by

CON.E

Communication

recovery of normal communication status. Check

 

error

connection of the communication cable. After checking

 

 

connection of the communication cable, reset the

 

 

extended panel. If the same indication appears again

 

 

after resetting, ask the dealer to investigate the cause.

ΓFor additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-2192

Image 5
Contents CAB0011 CAB0013 CAB0015 IntroductionConnections and Start Up Programming Parameter Description Default Value New ValueNames and Functions Mounting DimensionsSpecification SpecificationsProtection Functions ГON.ETransportation and installation Safety Precautions HandlingAbout disposal of the product Operation