• When the scanner cannot read a barcode...
Cause | Action |
• The top window of the scanner is dirty or dewed. | • Clean the top window. |
• Barcode system does not correspond to scanner | • Reading a barcode is unavailable. Use the barcode |
specification. | system corresponding to the scanner specification. |
• Barcode has a defect. (Print of a barcode is too | • Reading a barcode is unavailable. |
light, dirty, blurred, or defaced.) | Read a perfect barcode attached to the same article. |
| Enter the barcode of the article manually by the |
| keyboard. |
| (However, depending on the function of the host |
| terminal.) |
• Angle to read a barcode is not appropriate. | • Read the barcode at the appropriate angle. (Refer to |
| page 5 in details.) |
• Barcode to be read is too near to the top window | • Read the barcode in the effective scanning zone. |
or too far from the top window. | (Refer to pages 4 and 5.) |
When a trouble still exists after taking the actions described above, ask your TOSHIBA TEC representative.
•When the scanned data is not transferred to the host terminal...
Cause | Action |
• The connector of the interface cable has been de- | • Attach the connector securely. |
tached. |
|
When a trouble still exists after taking the action described above, ask your TOSHIBA TEC representative.
8.SPECIFICATIONS
8.1Scanner Main Body
Dimensions: | 200 (W) x 90 (D) x 220 (H) mm (Vertical standing dimensions) |
Weight: | 1.5 kg |
Readable code: | |
| |
| ITF (Interleaved 2 of 5), NW7 (CODABAR), |
| CODE39, CODE93, CODE128 |
Interface: | OCIA |
| |
| USB |
Reading Height: | Up to 200 mm above from the Scanner Window surface |
Input Power: | 12 VDC – 10% |
8.2Interface Cable (Option)
Cable Length: | 5.0 m |
- 8 -