Siemens PCS7 manual ElementeTM7.ocx V3.00.00 Input.ocx TM7x

Page 9

3.6Installation of the PCS7/TM-OCX (PCS7) (formerly: WinCC/TM-OCX (PCS7))

The image blocks in a PCS7-similar representation and the authorization DLL that is necessary for proper operation are located in the directory sw\OCX_TM7 on the CD.

The authorization is supplied on a separate floppy disk.

This package must be installed in all computers that shall be used for operator communication and visualization:

-Single-user system, also ES

-Multi-clients or Clients

-Server, if the server is operator station at the same time.

3.6.1Procedure of the manual installation

There is an older version of WinCC /TM-OCXen (PCS7) in your computer and the objects WinCC/TM-OCX (PCS7) and VB5_DLL are contained in the "Settings/System con- trol/Software" tab:

Uninstall these two objects.

To install the image blocks in PCS7-similar representation branch to the SW\ OCX_TM7 di- rectory and invoke Setup.exe there. The further install procedure will be prompted. Also install the VB6_DLL (in the same setup).

Any existing installation will be removed during this process.

The "Prototype images" option can be used for copying these images into the corresponding WinCC folder from where they will be copied into the project when the Split Screen Wizard executes.

The authorization must be transferred to the same drive as the other PCS7 authorizations. To do this, please insert the authorization floppy disk into the drive and double-click on the Authors.exe or Authorsw.exe program (same procedure as for other PCS7/ WinCC compo- nents).

Of course, this step is only necessary if an authorization has not yet been installed.

The image blocks in PCS7-similar representation are now ready for the configuration in the WinCC- Graphics Designer.

Note: Some image blocks in PCS7-similar representation need more parameters in the ORPA filter than the ones in TELEPERM M representation. Instead of the ORPAFilter.txt file that was copied into the <LW>:\Siemens\WinCC\BSTMapper directory during the installation of the TELEPERM M channel, ORPAFilter from the TM7 directory of the CD shall therefore be used. This directory also contains the prototype images.

3.6.2Revision levels

ElementeTM7.ocx

V3.00.00

Input.ocx

V3.00.00

TM7_x

V3.00.00

3.6.3What to do after the installation ?

After the successful installation all optionally installed prototype images may be copied with the WinCC-Split Screen Wizard into the current project.

Product Information

PCS7/TM V2.02

24.10.2001

© Siemens AG 2001

9 of 21

 

Image 9
Contents PCS7 / TM WinCC / TM V2.02 Product Information Chapter General Information CD content in generalWhat’s new ? Teleperm M channel∙ Switchover of the Servers after CS 275 Coupling Fault PCS7/TM-OCX Nora formerly WinCC/TM-OCX Nora∙ Channel Diagnosis Content of the CD General Information About the InstallationInstallation using the Common Installation Mask PCS7/TM-OCX PCS7 formerly WinCC/TM-OCX PCS7Product Information PCS7/TM 24.10.2001 Siemens AG Manual installation Installation of the Teleperm M Channel DLL and ToolsInstallation of the NAT/NPCI driver What to do after the Installation ?Revision levels Procedure of the manual installationElementeTM7.ocx V3.00.00 Input.ocx TM7x Product Information PCS7/TM 24.10.2001 Siemens AG Necessary TM Licenses Authorization Upgrade from WinCC/TM, V1.0x, to PCS7/TMImportant note Documentation ∙ WinCC/TM-OCXSymbole∙ WinCC/TM-OCXAS215 ∙ Teleperm Nora renoviertConversion of a PCS 7/TM Project from WinCC 4.0x to Version InterdependenciesProgram Released VersionsTransition from WinCC, V5.0, to V5.0/SP2 PCS7 Creating a Project for Multi-Client Operation on a Server Creating a new PCS 7/TM projectCreating a Multi-Client Project in a Multi-Client Parameter description ConfiguraAS488 Bridge Tion dialogImportant Notes Strings in TML Blocks Troubleshooting Tips ⊆ License Problems at RuntimeStructures of Field Blocks GA, GB, etc FontsAppendix Teleperm M in Intranet or InternetFiles and Search Paths Product Information PCS7/TM 24.10.2001 Siemens AG
Related manuals
Manual 18 pages 27.51 Kb

PCS7, TM specifications

Siemens TM, AS 488 is a state-of-the-art series of technological solutions designed to enhance various industrial processes. Siemens, a renowned leader in engineering and technology, has developed the TM, AS 488 mainly for use in manufacturing, automotive, and process industries. This series speaks volumes about Siemens’ commitment to innovation and operational excellence.

One of the key features of the TM, AS 488 is its advanced automation capabilities. This system integrates seamlessly with existing manufacturing processes, enabling real-time monitoring and control. The TM, AS 488 facilitates the connection between different machinery, allowing for a more cohesive operation across the production line. This results in reduced downtime and increased efficiency, making it an invaluable asset in modern manufacturing environments.

A significant aspect of the TM, AS 488 is its robust data analysis and processing capabilities. Equipped with powerful algorithms, the system can analyze vast amounts of data, providing actionable insights that can enhance decision-making. The predictive maintenance features built into the system help identify potential issues before they escalate, resulting in lower operational costs and improved asset longevity.

Moreover, the TM, AS 488 is designed with user-friendliness in mind. Its intuitive interface allows operators to easily navigate through various functionalities without extensive training. This focus on usability ensures that companies can quickly adapt to the system and begin reaping the benefits.

In terms of safety, the TM, AS 488 complies with international safety standards. It is equipped with multiple safety features that protect both the machinery and personnel operating within the manufacturing environment. This commitment to safety ensures that businesses can operate with peace of mind, knowing that they are minimizing risks associated with industrial operations.

Lastly, Siemens has ensured that the TM, AS 488 is scalable and flexible, catering to the needs of both small enterprises and large corporations. As businesses evolve, their operational needs may change; the TM, AS 488 can adapt accordingly, providing tailored solutions for varying requirements.

In conclusion, Siemens TM, AS 488 combines automation, data analysis, user-friendliness, safety, and scalability. These attributes highlight its position as a critical asset within the contemporary industrial landscape. Businesses looking to enhance their operational efficiency and embrace the future of manufacturing will find Siemens TM, AS 488 an ideal partner.