3.7Necessary TM Licenses (Authorization)

Authorizations are installed in the <LW>:AX NF ZZ directory.

Depending on the employed channel, the following authorization must be stored there:

TELEPERM M channel DLL CS 275/ L2:

AS 23x, AS 488, AS 215, AG 150U

 

AG 155U only

A7TMCS50

AS 220 only

A7T2CS50

AS 220 and AS 23x, AS488, AS 215,

AG 150U, AG 155U

A7TACS50

This authorization must be installed in all computers that communicate with an AS.

If the installed channel and the authorization are not compatible with each other, a box appears during runtime that states this incompatibility. The License.log file in the <LW>:\Siemens\WinCC\Diagnose directory tells you which license is required for the installed channel.

Image blocks PCS7/TM-OCX:

The authorization A7TMFP50 is uniformly required for all image blocks.

It must be installed on each PC where operator input and visualization is required

3.7.1Upgrade from WinCC/TM, V1.0x, to PCS7/TM, V2.0x

For this upgrade we offer the Upgrade package V2.0.

Changing from PCS7/TM, V2.00 to V2.01, or V2.01 to V2.02 the TM licences are not affected.

Important note:

Upon the migration from version V1.0x ... V1.05 to version V2.0 you will irrevocably lose the authorization for the previous version.

We recommend to perform the migration of the authorization prior to the installation of PCS7/TM. The migration requires the following preconditions to be fulfilled:

You possess a single license or a copy license for WinCC/TM; V1.0x on an authorization floppy disk or in your computer.

You have purchased an upgrade license to PCS7/TM V2.0 (referred to as "authorization upgrade" in the text below).

To upgrade the software from version V1.0x, use the following procedure:

1.The "old authorization" must be on the associated "old authorization floppy disk”. If necessary, you must first transfer this authorization from your computer onto the "old authorization floppy disk".

2.Insert the "authorization floppy disk - upgrade” and invoke the "AuthorsW" program via the start bar under Simatic > AuthorsW. If "AuthorsW" has not been installed in your computer, you must carry out the installa- tion from the CD ("Setup.exe" in the Authors / Disk 1 directory). The "Extras" menu contains a menu item "Upgrading guideline”. This guideline can support you during upgrading.

3.Select the "Authorization management" tab. Select the menu item "Upgrading..." from the "Authorization” menu.

4.Select the upgrade program from the dialog that is opened subsequently. You will then be prompted to insert the authorization floppy disk of the old authorization (V1.0x). Please follow the instructions on the screen and insert the "Authorization floppy disk - upgrade" when you are prompted to do so.

5.Upgrading will be terminated when the new authorization V2.0 is activated on the "Authorization floppy disk - upgrade".

6.The new authorization can now be transferred to your computer during the setup or using "AuthorsW”.

Product Information

PCS7/TM V2.02

24.10.2001

© Siemens AG 2001

11 of 21

 

Image 11
Contents PCS7 / TM WinCC / TM V2.02 Product Information Chapter Teleperm M channel CD content in generalGeneral Information What’s new ?∙ Channel Diagnosis ∙ Switchover of the Servers after CS 275 Coupling FaultPCS7/TM-OCX Nora formerly WinCC/TM-OCX Nora PCS7/TM-OCX PCS7 formerly WinCC/TM-OCX PCS7 General Information About the InstallationContent of the CD Installation using the Common Installation MaskProduct Information PCS7/TM 24.10.2001 Siemens AG What to do after the Installation ? Installation of the Teleperm M Channel DLL and ToolsManual installation Installation of the NAT/NPCI driverRevision levels Procedure of the manual installationElementeTM7.ocx V3.00.00 Input.ocx TM7x Product Information PCS7/TM 24.10.2001 Siemens AG Important note Necessary TM Licenses AuthorizationUpgrade from WinCC/TM, V1.0x, to PCS7/TM ∙ Teleperm Nora renoviert ∙ WinCC/TM-OCXSymboleDocumentation ∙ WinCC/TM-OCXAS215Released Versions Version InterdependenciesConversion of a PCS 7/TM Project from WinCC 4.0x to ProgramTransition from WinCC, V5.0, to V5.0/SP2 PCS7 Creating a Project for Multi-Client Operation on a Server Creating a new PCS 7/TM projectCreating a Multi-Client Project in a Multi-Client Tion dialog ConfiguraParameter description AS488 BridgeImportant Notes Fonts Troubleshooting Tips ⊆ License Problems at RuntimeStrings in TML Blocks Structures of Field Blocks GA, GB, etcFiles and Search Paths AppendixTeleperm M in Intranet or Internet Product Information PCS7/TM 24.10.2001 Siemens AG
Related manuals
Manual 18 pages 27.51 Kb

PCS7, TM specifications

Siemens TM, AS 488 is a state-of-the-art series of technological solutions designed to enhance various industrial processes. Siemens, a renowned leader in engineering and technology, has developed the TM, AS 488 mainly for use in manufacturing, automotive, and process industries. This series speaks volumes about Siemens’ commitment to innovation and operational excellence.

One of the key features of the TM, AS 488 is its advanced automation capabilities. This system integrates seamlessly with existing manufacturing processes, enabling real-time monitoring and control. The TM, AS 488 facilitates the connection between different machinery, allowing for a more cohesive operation across the production line. This results in reduced downtime and increased efficiency, making it an invaluable asset in modern manufacturing environments.

A significant aspect of the TM, AS 488 is its robust data analysis and processing capabilities. Equipped with powerful algorithms, the system can analyze vast amounts of data, providing actionable insights that can enhance decision-making. The predictive maintenance features built into the system help identify potential issues before they escalate, resulting in lower operational costs and improved asset longevity.

Moreover, the TM, AS 488 is designed with user-friendliness in mind. Its intuitive interface allows operators to easily navigate through various functionalities without extensive training. This focus on usability ensures that companies can quickly adapt to the system and begin reaping the benefits.

In terms of safety, the TM, AS 488 complies with international safety standards. It is equipped with multiple safety features that protect both the machinery and personnel operating within the manufacturing environment. This commitment to safety ensures that businesses can operate with peace of mind, knowing that they are minimizing risks associated with industrial operations.

Lastly, Siemens has ensured that the TM, AS 488 is scalable and flexible, catering to the needs of both small enterprises and large corporations. As businesses evolve, their operational needs may change; the TM, AS 488 can adapt accordingly, providing tailored solutions for varying requirements.

In conclusion, Siemens TM, AS 488 combines automation, data analysis, user-friendliness, safety, and scalability. These attributes highlight its position as a critical asset within the contemporary industrial landscape. Businesses looking to enhance their operational efficiency and embrace the future of manufacturing will find Siemens TM, AS 488 an ideal partner.