Siemens 2XV9450-1AR82 user manual Connection to Siclock TS, Parametering required for Siclock TS

Page 26

User Manual SICLOCK GPS1000

2.2. Connection to SICLOCK TS

Fig. 4 shows in schematic diagram the installation of SICLOCK TS without lightning protection . The parts illustrated in photo and the grey cable are included in the scope of delivery for the complete package SICLOCK GPS1000. The red cable must be made available on site.

Fig 4: Installation diagram for SICLOCK TS without lightning protection module.

Parametering required for SICLOCK TS:

1.Set input E1 to “GPS1000” . (See also operating manual SICLOCK TS)

2.Set time zone according to the location in relation to GMT.

8

Version 1.0

Order number 2XV9450-1AR82-BA

Image 26
Contents Siclock GPS1000 2XV9450-1AR82Bestellungen Verantwortlicher VertriebAnsprechpartner Siemens AGInduktionswirkung bei Blitzeinschlägen InhaltsverzeichnisAbbildungsverzeichnis Montage der AntenneFunktion Vorgehen bei der InstallationSchnelleinstieg LieferumfangBetrieb und Wartung Installationsschemen Anschluss an Siclock TM oder PCWichtig Erforderliche Parametrierung bei Siclock TMAnschluss an Siclock TS Erforderliche Parametrierung bei Siclock TSWichtig Blitzschutz BlitztheorieEinschlaggefährdete Bereiche bei Gebäuden Induktionswirkung bei BlitzeinschlägenInstallation des Blitzschutzmoduls 2XV9450-1AR83 Auswahl des sicheren StandortesVorgehensweise bei der Montage Montage der AntenneVorgehensweise bei der Auswahl des Montageortes Abbildung 10 Wandmontage Bestell-Daten AnhangTechnische Daten Genauigkeiten AntennenfußgestellNotizen Version Bestellnummer 2XV9450-1AR82-BA Siclock GPS1000 Radio Clock Contact person OrdersContents Index of IllustrationsFunction Installation ProcedureBrief Overview Scope of DeliveryOperation and Maintenance Installation instructions Connection to Siclock TM or PCParametering required for Siclock TM Connection to Siclock TS Parametering required for Siclock TSOrder numberr 2XV9450-1AR82-BA Version Lightning Protection Lightning TheorieParts of buildings in danger of being struck by lightning Inducting effect during lightning strikes Choosing a safe locationMounting the antenna Procedure for selecting the installation locationMounting procedures Wall mounting Appendix Technical dataPower supply for operation with Siclock TM or PC Antenna head with mounting standPrecision Antenna standOrder numberr 2XV9450-1AR82-BA Version Version
Related manuals
Manual 21 pages 48.33 Kb

2XV9450-1AR82 specifications

The Siemens 2XV9450-1AR82 is a versatile component designed for various industrial applications, known for its reliability and efficiency. Part of Siemens’ extensive portfolio, this device plays a critical role in optimizing system performance and ensuring sustainable operations in numerous environments.

One of the main features of the 2XV9450-1AR82 is its ability to function under diverse conditions while maintaining high operational efficiency. This component is engineered to operate at a wide temperature range, allowing it to perform reliably in both extreme heat and cold without compromising on functionality.

The technology utilized in the Siemens 2XV9450-1AR82 includes advanced electronic circuitry that enhances its performance capabilities. This feature enables seamless integration with other components in a system, promoting coordinated operations and enhanced reliability. Moreover, the use of state-of-the-art materials in its construction ensures durability, contributing to its longevity and low maintenance costs.

Another significant characteristic of the 2XV9450-1AR82 is its energy efficiency. In an era where energy conservation is critical for both environmental and economic reasons, this component is designed to minimize energy consumption. This not only reduces operational costs but also helps companies meet sustainability goals, making it an attractive option for businesses focused on minimizing their ecological footprint.

The flexibility of the Siemens 2XV9450-1AR82 allows it to be used in a variety of sectors, including manufacturing, transportation, and energy management. Its adaptability means that it can meet the specific needs of different industries, thereby enhancing operational effectiveness across various applications.

Additionally, the built-in diagnostic features of the 2XV9450-1AR82 provide users with essential information regarding performance status and potential issues. This proactive approach to maintenance ensures that potential problems are addressed before they escalate, reducing downtime and improving overall productivity.

In summary, the Siemens 2XV9450-1AR82 stands out for its robust features, advanced technology, and efficiency, making it an invaluable asset in modern industrial applications. Its ability to adapt to various environments and its focus on energy savings reflect Siemens' commitment to innovation and sustainable development in the industry. As industries continue to evolve, the Siemens 2XV9450-1AR82 remains a key component in driving progress and enhancing operational capabilities.