Fig 10: Wall mounting
1 - Antenna head
2 - Cube with 6 hexagon socket set screws
3- Allan key for cube installation
4 - Sealing cover
5 - Antenna stand with base plate and holding arm
(a)Mark the position of the holes for mounting in the planned place with the aid of the base plate (5), drill the holes and insert dowels.
.
(b)When preparing to install the antenna, it must be taken into account whether the antenna is to be assembled for wall mounting or flat roof installation.
•When installing the antenna on a flat roof, (Fig 9), the connecting cable of the antenna head (1) is inserted in a straight line through 2 opposite openings of the cube (2), the antenna head support is then pushed into the opening of the cube as far as it goes, and tightened gently on the left and on the right with the 2 hexagonal socket set screws as provided.
Now the connecting cable is inserted from above through the antenna stand (5), the cube (2) is pushed in as far as it goes on the holding arm and tightened gently on the left and on the right with the 2 hexagonal socket set screws as provided. After radial ad- justment (which has no influence on the reception properties) of the parts (loosen the hexagonal socket set screws again) the hex- agonal socket set screws are then retightened.
Finally the opening in the cube (2) is then closed with the sealing cover (4) and the two hexagonal socket set screws are then tightened gently on the left and right.
•For wall mounting (Fig. 10), the connecting cable of the antenna head (1) is inserted through the cube (2) at a right angle, the an- tenna head support is pushed into the opening of the cube as far as it will go and the two hexagonal socket set screws gently screwed tight on the left and right.
Now the connecting cable is inserted from above through the antenna stand (5), the cube (2) is pushed in as far as it goes on the holding arm and tightened gently with the 2 hexagonal socket set screws as provided, on the left and on the right. Set up the stand, loosen the hexagon socket set screws again, align the cover surface of the antenna head parallel to one edge of the base plate and tighten the hexagon socket set screws.
Finally the remaining opening in the cube (2) is closed with the sealing cover (4) and the two hexagon socket set screws left and right are screwed tight.
.
c)The drill hole through the wall or through the roof is best made in the middle underneath the base plate. The connecting cable is inserted through the drill hole and the complete antenna stand screwed on.
Alternatively, the connecting cable can also be laid through the slot in the base plate and led outside the base plate through the wall or roof.