LIT_PRO7000_manual.qxd 11/10/2003 4:30 PM Page 9
C)Set the Outlet Pair to SWITCHED ON AFTER DELAY: Press MENU until the display shows the status of the Analog outlet pair. Press the SET button until the time delay changes to the required delay in seconds before the outlet pair will turn on after the ON/OFF button is pressed, as in figure 4.
When the PowerSource is SWITCHED ON by pressing the front panel ON/OFF button, or by an external trigger signal, the outlet pair will go “live” after the time delay set as described above — 20 seconds in this case. The outlet pair with the maximum time delay setting will still turn off immediately when the ON/OFF button is pressed, or when triggered by an external signal.
D)Set the Outlet Pair to UNSWITCHED (Always On): Press the MENU button until the display shows the status of the Analog outlet pair. Press the SET button until you see the display in figure 5.
Once UNSWITCHED is selected, any component plugged into those outlets will receive power continuously as long as your PowerSource is plugged into a 120 volt wall socket.
Note: The unit is shipped with all outlet pairs set to SWITCHED ON.
8