ADC HDSL Hdsl Interface Line Code, Line Rate, Output, Maximum Provisioning Loss, Range, Data Rate

Page 3

1 1 / 0 8 • 1 0 6 8 0 5 A E   WorldDSLHDSL

WorldDSLHDSL

Economical, Reliable, and Manageable E1 and Serial Data Deployment

Specifications

HDSL Interface

 

Line Code:

2B1Q

Line Rate:

1168 kbps on each pair

Output:

13.5 dBm ± 0.5 dB

Maximum Provisioning Loss:

35 dB at 292 kHz

Range:

See Figures 1, 2 and 3

HDSL Connector:

See specific enclosure for external DSL interface connection type

Secondary Protection:

Provided on LTU, UTU, and EDU

LTU/UTU Protection Compliance:

ITU-T K.20 and K.21 compliant when used in

 

ADC Chassis and Enclosures

EDU Protection Compliance:

ITU-T K.17

EDU Primary Protection:

Integrated gas discharge tubes when used in EDU enclosures

EDU Protection Compliance:

ITU-T K.17 when used in ADC enclosures

Other Compliances:

ETSI TS101135 and ITU-T G.991.1

E1 Interface

 

Line Code:

HDB3

Data Rate:

2048 kbps

Operation:

Full or fractional

Blocking:

Per 64 kbps channel

Idle Code Insertion:

User selectable word

Impedance:

120 Ω balanced or 75 Ω unbalanced

Framing:

Structured with or without CRC-4 or unstructured

Connectors:

Both D15F (balanced) and BNC (unbalanced)

Timing:

G.703 or external

Compliance:

ITU-T G.703, G.704, G.706, G.821, G.823, CTR12

Data Interface

 

User software selectable as:

V.35, V.36, RS-530, X.21

Connector:

D25F (adapters available)

Timing:

Internal, external, Nx64k, HDSL

Compliance:

Net 2

Performance Monitoring

 

HDSL:

Noise margin, pulse attenuation, ES, UAS

E1:

ITU-T G.821

Alarms:

Form C relay contacts

HDSL Loopbacks:

LTU or UTU local or remote towards Network or Customer EDU

 

towards Network

E1 and Serial Data Loopbacks:

Local or remote towards Network or Customer

Test Pattern:

PRBS generator and BER meter

Power

 

Input Power:

-36 to -72VDC for LTU and UTU when locally powered

 

75VDC to 120VDC Tip to Ring for UTU or EDU when

 

span powered from LTU

Power Consumption:

5W for line or locally powered UTU

 

5W for LTU with line powering off

 

15W for LTU with line powering on

 

2.5W for line powered EDU

Physical

 

LTU and UTU Dimensions (HxWxD):

6.89" x 0.925" x 8.45" (175 mm x 24 mm x 215 mm)

Weight

 

LTU:

0.81 lbs. (0.37 Kg)

UTU:

0.61 lbs. (0.28 Kg)

EDU Dimensions (HxWxD):

2.6" x 1.46" x 6.5" (66 mm x 37 mm x 165 mm)

EDU Weight:

1.8 lbs. (0.82 kg)

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

3

Image 3
Contents Line and Universal Terminating Units Spec SheetTypical Single Span Applications HdslAlarms Hdsl ConnectorConnectors ConnectorLTU Chassis and Enclosures Environmental Operating TemperatureStorage Temperature Safety