ADTRAN DSU 56 user manual DTE with Test Pattern TP

Page 31

Chapter 3. Test Modes

To initiate the DTE ONLY test, perform the following steps:

1.Press SELECT once to turn on the DTE test indicator.

2.Press TEST while the test indicator is on.

3.To terminate the test, press TEST.

Test data from the terminal or test equipment is routed through the DTE section of the DSU 56/64 and then to the output of the loop transmitter section where the signal is encoded for transmission. The output of the loop transmitter is coupled back to the loop receiver input. The received test signal is then decoded and returned to the terminal or test equipment where it is checked for any bit errors.

DTE WITH TEST PATTERN (TP)

The DTE WITH TP test is similar to the DTE ONLY TEST described in Figure 3-1 on page 3-2. It is initiated at the local DSU 56/64 and is used to independently test the operation of the DSU 56/64.

To initiate the DTE WITH TP test, perform the following steps:

1.Press SELECT twice to turn on both the DTE and PTRN test indicators.

2.Press TEST while these test indicators are on.

3.To terminate this test, press TEST.

Instead of using data from the terminal or test equipment, this test utilizes an internal test pattern generator and detector in the DSU 56/64. The loopback point and the data paths for this test are illustrated in Figure 3-2 on page 3-4.

61200062L1-1

DSU 56/64 User Manual

3-3

Image 31
Contents DSU 56/64 Page Save These Important Safety Instructions Important Safety InstructionsAffidavit Requirements for Connection to Digital Services Page Page Service Type Digital Facility Service Order Code Canadian Emissions Requirements Canadian Equipment Limitations Limited Product Warranty Repair and Return Customer Service, Product Support Information, and TrainingPresales Inquiries and Applications Support Post-Sale SupportTraining Table of Contents Appendix A. Pinouts Appendix B. Specifications Index Index-1 DSU 56/64 Unit List of FiguresList of Figures Xvi List of Tables List of Tables Xviii Product Overview IntroductionNetwork Status Red Front PanelLoop Test Status/Error Yellow/RedBeing utilized for testing Test SwitchesDSU 56/64 Rear Panel Rear PanelUNPACK, INSPECT, Power UP InstallationUp On ConfigurationClear to Send Delay CS Delay SW Switch Position Clear To Send CS SW Down NormalData Set Ready SR SW Down On Antistream SWDown Off Carrier Detect CD SE Down NormalUp 64 kbps Remote Digital Loopback RDL SW Down EnableUp Disable Loop Rate SW Down 56 KbpsDTE Connections Default Option Switch SettingsSwitch Position Setting Network ConnectionsInstallation Test Modes Self TestDTE only Test Near END TestsDTE with Test Pattern TP DTE and Loop Test LL DTE with TP Test DiagramDTE and Loop Test Diagram Loop only Test RT Loop Only Test DiagramRemote Digital FAR END TestsTest Pattern Ptrn Remote Tests Test Modes Appendix a Pinouts Pin Table A-2. V.35 DTE PinoutsDescription Specifications and Features Appendix B SpecificationsEnvironment DiagnosticsPower Hardware SpecificationsIndex Index-2

DSU 56 specifications

The ADTRAN DSU 56 is an essential device for businesses and organizations looking to establish reliable serial communication over digital circuits. A Data Service Unit (DSU) acts as a bridge, converting digital data from a Local Area Network (LAN) into a format suitable for transmission over telephone lines or other digital links. The DSU 56 is specifically designed to operate at 56 Kbps, making it a vital component in many networking setups where higher bandwidth is unnecessary.

One of the main features of the ADTRAN DSU 56 is its ability to support a variety of interfaces. It is equipped with both V.35 and RS-232 ports, allowing for flexible connectivity options to diverse networking equipment and configurations. This versatility ensures that organizations can easily integrate the DSU 56 into their existing telecommunications infrastructure.

The DSU 56 is built on advanced technologies that ensure efficient data transfer and reliability. It incorporates error correction mechanisms and extensive diagnostic capabilities, which help identify and troubleshoot issues quickly. This is particularly important in mission-critical applications where downtime can lead to significant operational disruptions.

In addition to reliable data conversion, the DSU 56 offers features like loopback testing and performance monitoring. These functionalities enable network administrators to assess the health and performance of the connection with ease. Loopback tests can be initiated locally or remotely, allowing for thorough testing of the entire data path without disrupting ongoing operations.

Another notable characteristic of the ADTRAN DSU 56 is its compact and robust design. It is built to withstand various operating conditions, making it suitable for deployment in different environments, including data centers and remote installations. The device is also energy efficient, contributing to lower operational costs.

The DSU 56 supports various protocols, such as Frame Relay and PPP, ensuring compatibility with numerous public and private network infrastructures. This adaptability makes it a valuable asset for businesses transitioning to digital communication systems or those seeking to enhance their existing setups.

In conclusion, the ADTRAN DSU 56 stands out as a reliable and versatile solution for organizations needing to facilitate effective data communication over digital circuits. Its robust features, combined with advanced technologies, position it well in the marketplace, making it a choice for businesses focused on maintaining high-quality connectivity.