Chapter 2. Installation
Power Up
The DSU 56/64 is equipped with a captive
Ensure that a grounded, 115 VAC, 60 Hz receptacle is used for powering the DSU 56/64 unit.
CONFIGURATION
The DSU 56/64 has eight options for controlling the operation of both the network and DTE interfaces. These options are selected by setting individual switches on either position DIP switch that is accessible from the rear panel. A chart showing the options and switch settings is attached to the bottom of the unit.
Clear To Send (CS) - SW 1
Down - Normal
In the down position, CS follows the RS lead with the selected amount of delay. The only exceptions to this occur when network or test conditions prevent data from being transferred over the DTE interface. During these conditions CS is turned off.
Up - On
CS is forced on all the time.
Clear to Send Delay (CS Delay) - SW 2
Switch Position
RS to CS Delay
Down - Short 250 ∝ s + 125 ∝ s
Up - Long
10 ms + 125 ∝ s
DSU 56/64 User Manual |