Patch | 7 |
PCR: 01234 | Module: SWI | Network affecting: No |
A switch port that was transmitting STP BPDUs and also mirroring its transmit traffic to the mirror port caused a fatal error. This issue has been resolved.
Features in 86222-06
Patch file details for Patch 86222-06 are listed in Table 5.
Table 5: Patch file details for Patch
Base Software Release File | |
|
|
Patch Release Date | |
|
|
Compressed Patch File Name | |
|
|
Compressed Patch File Size | 226776 bytes |
|
|
Patch
PCR: 01188 | Module: SWI | Network affecting: No |
The power supply voltages of the base board PHYs on a Rapier G6 are controlled by a PHY register value, which was incorrectly set. This issue has been resolved.
PCR: 01190 | Module: PIM | Network affecting: No |
In PIM Dense Mode, if a data stream started before PIM hello messages were exchanged, the receiver did not get the data stream. This issue has been resolved.
PCR: 01192 | Module: SWI | Network affecting: No |
The Rapier G6 base ports sometimes experienced spurious link up or link down events. This issue has been resolved.
Features in 86222-05
Patch file details for Patch 86222-05 are listed in Table 6.
Table 6: Patch file details for Patch
Base Software Release File | |
|
|
Patch Release Date | |
|
|
Compressed Patch File Name | |
|
|
Compressed Patch File Size | 223728 bytes |
|
|
Patch
Patch