3Com V7122 manual Assigning an IP Address Using BootP

Page 25

Assigning an IP Address Using BootP

BootP procedure can also be performed using any standard compatible BootP server.

You can also use BootP to load the auxiliary files to the V7122 gateway (see the V7122 Digital Gateway User Guide).

To assign an IP address using BootP, follow these 13 steps:

1Open the BootP application (supplied with the V7122 gateway software package).

2Click on the Edit Clients icon ; the Client Configuration screen is displayed.

3Click on the Add New Client icon ; a client with blank parameters is displayed (Figure 11).

4In the Client MAC field, enter the MAC address of the gateway. The MAC address is printed on a label located on the base of the V7122 gateway.

5Verify that the check to the right of the Client MAC field is selected. This enables the particular client in the BootP tool (if the client is disabled, no replies are sent to BootP requests).

6In the Client Name field, enter a descriptive name for this client so that it is easier to remember which gateway the record refers to. For example, this name could refer to the location of the gateway.

7In the IP field, enter the IP address you want to assign the gateway. Use the normal dotted decimal format.

8In the Subnet field, enter the subnet mask you want to assign the gateway. Use the normal dotted decimal format. Ensure that the subnet mask is correct. If the address is incorrect, the gateway may not function until the entry is corrected and a BootP reset is applied.

9In the Gateway field, enter the IP address for the default gateway. If you do not know the IP address for the default gateway, contact your network administrator.

10Click Apply to save this entry to the list of clients.

11Click OK; the Client Configuration screen is closed.

12Use the reset button (located on the V7122 gateway front panel) to physically reset the gateway causing it to use BootP; the V7122 gateway changes its network parameters to the values provided by the BootP.

13Repeat Steps 2 through 11 for the V7122 gateway’s second module (if used).

V7122 Digital Gateway Installation Guide

25

Image 25
Contents V7122 Digital Gateway Installation Guide United States Government Legend 3Com Corporation, 350 Campus Drive, Marlborough MAContents Upgrading the V7122 Gateway About this Guide How to Use This GuideModel Numbers for the V7122 Gateways ConventionsDocumentation Comments Icon DescriptionWeee EU Directive ExampleAbbreviations and Terminology V7122 Digital Gateway Installation Guide Quick Start V7122 Digital Gateway Installation Guide Item # Label Component Description Installing the V7122 GatewayUnpacking Package ContentsMounting the V7122 Gateway Installing the V7122 Gateway in a 19-inch RackMounting the V7122 Gateway on a Desktop V7122 Gateway Front View with 19-inch Rack Mount Brackets Cabling the V7122 Gateway Electrical Earthing Pin Numbers Connecting the E1/T1 Trunk InterfacesInstalling the Ethernet Connection RJ-48c Connector and PinoutE1/T1 Number Tx Pins Tip/Ring Rx Pins Tip/Ring Connecting the AC Power Supply Connecting the Power SupplyConnecting the DC Power Supply Page V7122 Digital Gateway Installation Guide V7122 Gateway Version Default Value Configuring the V7122 GatewayAssigning the V7122 Gateway IP Address Assigning an IP Address Using Http Assigning an IP Address Using BootP Client Configuration Screen with Blank Parameters Assigning an IP Address Using the CLIRestoring Networking Parameters to their Initial State To access the Embedded Web Server, follow these 4 steps Accessing the Embedded Web ServerV7122/H.323 Quick Setup Configuring Basic H.323 ParametersPage V7122/SIP Quick Setup Configuring Basic SIP ParametersPage Configuring the Trunk Settings Indicator Color Description Trunks Status Color Indicator KeysV7122 Digital Gateway Installation Guide V7122 Digital Gateway Installation Guide Changing the V7122 Gateway Username and Password V7122 Digital Gateway Installation Guide Configuration File Screen Restoring and Backing UP the V7122 Gateway ConfigurationV7122 Digital Gateway Installation Guide TP-1610 Front Panel LED Indicators V7122 Gateway Chassis LED IndicatorsMonitoring the V7122 Gateway Monitoring the V7122 Gateway LEDsLabel LED Color Signal Description E1/T1 Trunk Status LED IndicatorsTrunk & Channel Status Screen Monitoring the V7122 Gateway Trunks and B-channelsV7122 Digital Gateway Installation Guide Upgrading the V7122 Gateway Software Upgrade WizardStart Software Upgrade Screen V7122 Digital Gateway Installation Guide Load an ini File Screen Load a CPT File Screen End Process Screen File Type Description Updating the Auxiliary FilesAuxiliary Files Screen for example, SIP Gateways Declaration of Conformity Regulatory InformationSafety Notices Digital Device Warnings Industry Canada NoticeNetwork Information and Intent of Use Network CompatibilityPorts Safety Status Telecommunication SafetyFCC Statement Customer Support Appendix a Obtaining Support for Your 3COM Product

V7122 specifications

The 3Com V7122 is a robust and versatile Layer 2/3 switch designed for small to medium-sized enterprises seeking a reliable networking solution. It plays a crucial role in improving network performance and enhancing connectivity for a growing number of devices in today’s digital landscape.

One of the standout features of the V7122 is its advanced switching capabilities. It supports 24 Ethernet ports, providing ample connectivity options for various end devices like computers, printers, and cameras. The switch offers a combination of copper and fiber interfaces, ensuring flexibility in deployment, whether for short-range or long-range connectivity.

The V7122 is equipped with a sophisticated traffic management system, which includes Quality of Service (QoS) features. This allows organizations to prioritize network traffic according to application requirements, ensuring bandwidth is allocated effectively. With this capability, time-sensitive applications such as voice-over-IP (VoIP) and video conferencing can function smoothly without interruption.

Another significant technology incorporated into the 3Com V7122 is its compatibility with VLAN (Virtual Local Area Network) configurations. This feature enables the segmentation of a network into multiple virtual networks, enhancing security and reducing congestion by limiting broadcast traffic. The ability to create subnets helps organizations to better manage their network resources and maintain optimal performance.

Moreover, the V7122 supports various network protocols, facilitating seamless integration within existing IT infrastructures. Its stackable design allows for easy scaling, enabling businesses to expand their network as needed without a complete overhaul. The switch also boasts an intuitive user interface, which simplifies management and configuration processes, making it accessible to network administrators of varying skill levels.

The 3Com V7122 stands out for its reliability and durability as well. It is built to handle the demands of an enterprise environment, featuring a compact and robust chassis designed for continuous operation. With the ability to support power over Ethernet (PoE), the switch can power connected devices directly through the Ethernet cable, eliminating the need for separate power supplies and reducing cable clutter.

In conclusion, the 3Com V7122 is a powerful networking solution that combines advanced switching features, traffic management capabilities, and flexible configurations. Its compatibility with various technologies and protocols makes it an ideal choice for organizations looking to optimize their network infrastructure for current and future demands.