Charging Rechargeable Batteries

Your scanner has a built-in charging circuit that lets you charge nickel-metal hydride (Ni- MH) or nickel cadmium (Ni-CD) rechargeable batteries (not supplied) while they are in the scanner. To charge rechargeable batteries, connect an appropriate AC or DC adapter to the PWR DC 9V jack. For best results we recommend RadioShack rechargeable nickel-metal hydride (NiMH) 1600mAh batteries. !

To charge batteries with a DC adapter from a DC power source, you must use a 9V, 300 mA DC adapter such as RadioShack Cat. No. 273-1810 or 273-1815 and a size B Adaptaplug™ (neither supplied). Both are available at your local RadioShack store. Make sure the adapter's voltage is set to 9V. Ô

It takes about 16 hours to recharge fully discharged 1600mAh NiMH rechargeable batteries. You can operate the scanner while recharging the rechargeable batteries, but charging takes longer.

USING AC POWER

You can power the scanner using a 9V, 300 mA AC adapter and a size B Adaptaplug (neither supplied). Both are available at your local RadioShack store.

oWARNING o

Always dispose of old batteries promptly and properly. Do not bury or burn them.

CAUTION

If you do not plan to use the scanner with batteries for a month or longer, remove the batteries. Batteries can leak chemicals that can destroy electronic parts.

Ô NOTE Ô

The scanner can also charge Ni-Cd batteries. 600mAh batteries require 6 hours and 850mAh batteries require 8 hours to charge.

When you charge Ni-Cd batteries, do not overcharge them. Overchar- ging shortens battery life.

Rechargeable batteries last longer and deliver more power if you let them fully discharge once a month. To do this,

use the scanner

until Low Battery!

appears. Then fully charge the rechargeable batteries.

Preparation

11

Image 11
Contents PRO-95 Dual Trunk-Tracking Handheld Scanner Features Automatic Channel Your scanner includes these featuresSimultaneous Trunking Reviewing Locked Features FCC Wants YOU to Know Vehicle using a DC adapter not suppliedScanning Legally FCC Wants You to Know Preparation Using BatteriesPower Sources Using Vehicle Battery Power on Page 12 ÔPull the battery holder out of the battery compartment Charging Rechargeable Batteries Using AC PowerUntil Low Battery Connecting Antenna Using Vehicle Battery PowerListening Safely Connecting an Optional AntennaConnecting AN EARPHONE/HEADPHONES Connecting AN Extension Speaker Traffic SafetyTransferring Data to From Another Scanner or a PC Using the Belt ClipAbout Your Scanner About Keypad Mode changes the receive mode AM, FM, MOT, ED CL clears an incorrect entry TUV enters an 8, or inputs characters T, U, orPreprogrammed Search Banks Quick StartUnderstanding Banks Channel Storage BanksSearch Banks Understanding Your Scanners ModesMotorola Mode AM ModeUnderstanding Your Scanners Modes FFF=Fleet ID SS=Subfleet ID Edacs ModeOr using an outdoor antenna to improve reception Open and Closed Modes Storing Known Frequencies Into Channels Turning on Scanner and Setting SquelchOperation Operation Invalid Freq briefly Storing Trunking Frequencies Into ChannelsStoring Text Tags Assigning a Text Tag to a ChannelAssigning a Text Tag to a Group ID Press Character Assigning a Text Tag to a BankBank Band Searching a Preprogrammed Frequency Range# @ + Finding and Storing Active FrequenciesOperation Channel Frequency MHz Band ChartsSearch bank SR0 Marine band Receive mode FM Search bank SR1 CB band Receive mode AM Group Frequency MHz Step KHz Search bank SR2 Police/Fire band Receive Mode FMFrequency MHz Step KHz 108.000-136.9875 Search bank SR3 Aircraft Receive mode AMSearch bank SR4 Ham band Receive mode FM Finds an active frequency, it stops searching. Ô Air and Limit search bands Manually Tuning a FrequencyListening to Weather Band ** PausedWeather information on one or more of these channels Digitally-encoded Same signal when an alert is broadcast,Listening to a Weather Channel Displaying Weather MessagesDIG WX Stby appears Using Frequency CopyWX Alert and Beep Tone Confirmation Copying a Frequency into a Specified ChannelSecond, the frequency to be copied flashes Scanning Channels Copying a Frequency into the Priority ChannelTurning Channel-Storage Banks Off and On Deleting Frequencies from ChannelsLocking OUT Channels or Frequencies Special FeaturesUsing the Delay Function Locking Out ChannelsReviewing Locked-Out Frequencies Reviewing the Lock-Out ChannelsLocking Out Frequencies Lockout list appears Press any key other than 1 to cancel clear. ÔClearing a Locked-Out Frequency Clearing All Locked-Out Frequencies in a Search BankManual again To turn off the priority feature, press PRI Changing the Receive ModeMight have to change the receive mode Using the AttenuatorPress Func and then ATT to set Using the Display BacklightTurning the KEY Tone on and OFF Use Up/Down keys to set Lit off time 5 seconds appears Using the Keylock10 or 20 seconds then press Press or to select 3Cloning Programmed Data Changing the Display ContrastDown keys to set contrast. appears Trunking Operation TrunkingUnderstanding Trunking Follow these steps to program trunked frequencies Setting Squelch for the Trunking ModeProgramming Trunking Frequencies Way radio users transmission on a control channelPress PGM and press or hold Down or to select the bank. Ô Press Trunk to enter the ID program modePress PGM to enter the program mode Trunked. PressP001~ Programming Motorola Trunking50.0 or 12.5 kHz, then press Bank Press Mode and select MOTPress or to select Down keys to set 800MHz base. Normal appearsNormal or Offset and press Programming Fleet MapsBlock Size Code Block 0 size code. Use 15 for type II. S-00 appearsEnter the correct size code. Ô Press Scan to start scanning Talk Group IDSStoring Talk Group Desired bank MOTMOT none Memory fullTalk Group ID Hold ID NoInvalid ID. appears Dupl IDPress PGM. Ô Press Trunk Turning AN ID SUB- Bank on or OFFLocking OUT Talk Group IDS To release ID hold, press Scan or1.0, 1.5, 2.0, 2.5, 3.0, 3.5 or Seconds Delay Function in ID Indication ModeKeys to set ID delay .0 seconds Motxxxxxx or EdxxxxAny locked out IDs in a bank Reviewing LOCKED-OUT Talk Group IDSClearing Talk Group Clearing ALL Talk Group IDS in ONE BankOr vice versa Repeat Steps 2 and 3 for each bank Changing OPEN/CLOSED ModeBirdie Frequencies General Guide to FrequenciesUS Weather Frequencies HAM Radio FrequenciesUHF High Band MHz UHF Low Band MHzVHF High Band MHz VHF Low Band MHzVHF Band Guide to the Action BandsTypical Band Usage HF BandVHF Band UHF BandFrequencies MHz Abbreviation ServiceBand Allocation UHF BandFire VHF Low Band MHz-in 5 kHz steps MHz-30 MHzCB Band 26.965-27.405 MHz Meter Amateur Band 28.0-29.7 MHz MHz-300 MHz137-144 MHz Meter Amateur Band 50-54 MHzAircraft Band 108-136 MHz Government BandIND, MOV Low Band 450-470 MHz Ultra High Frequency UHF 300 MHz-3 GHzGovernment Band 406-420 MHz Centimeter Amateur Band 420-450 MHzCentimeter Amateur Band MHz in 6.25 kHz steps Public Safety Band Locally Assigned in 6.25 kHz stepsTrunked Systems Band Locally Assigned 6.25 kHz steps Centimeter Amateur Band KHz steps Frequency ConversionPrivate Trunked Band in 6.25 kHz steps General Trunked Band in 6.25 kHz stepsFrequency Conversion Problem Possible Cause Remedy TroubleshootingBottom line RESETTING/ Initializing the ScannerResetting the Scanner Initializing ScannerFrequency Coverage MHz SpecificationsCare ID memory banks Intermediate Frequencies if 1st 380.8 MHz RG-8/RG-58 50-Ohm Coaxial Cable Parts AccessoriesExternal Antenna MHz Antenna9V, 300 mA AC Adapter Connecting CableTo AC power PC Interface CablePage Page Page Fort Worth, Texas Limited One-Year WarrantyRadioShack Corporation