PREPARING FOR OPERATION

1.Check the heater for possible shipping damage. If any is found, immediately notify the factory.

2.Follow all of the "Precautions".

3.Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinder's valve outlet and securely tighten with a wrench.

4.Connect the hose to the heater by rotating the hose fitting clockwise.

5.Securely tighten all gas connections.

6.Open the cylinder's gas valve and check all gas connections with a soap and water solution. DO NOT USE A FLAME.

7.Connect power cord to well-grounded 115V, 60 Hz, 1Ø source of power.

8.When using an extension cord, make certain that it is a 3-wire (grounded) cord of proper wire size, minimum length of 6 ft (1.83m).

START

1.THE HEATER POWER CORD MUST BE CONNECTED TO A GROUNDED 115V, 60HZ, 1Ø POWER SOURCE BEFORE HEATER IGNITION and always allow heater fan (blower) to run for 20 seconds to purge fuel.

2.Open propane supply valve on propane tank slowly. Note: If not opened slowly, excess-flow check valve on propane tank will stop

gas flow. If this happens, close propane supply valve and open again slowly. Wait 15 seconds before Step 3.

3.Push and hold automatic control valve button. Push piezo ignitor button repeatedly until the burner lights.

4.After the burner lights, keep the gas valve button depressed for 30 seconds then release and the heater will continue to operate.

WARNING: Be sure motor and fan are running before pushing in automatic control valve button. Flames could flash outside heater or internal damage to heater may result if motor and fan are not running.

STOP

1.Securely close valve on the propane cylinder.

2.Continue to operate heater until all fuel in the hose has burned.

3.Unplug the power cord.

CAUTION: Always shut off fuel supply before disconnecting electrical power.

RESTART AFTER SAFETY SHUTDOWN

1.Securely close valve at propane cylinder. Unplug power cord.

2.Wait 5 minutes.

3.Restart following "START" procedure.

MAINTENANCE AND STORAGE

1.The heater should be inspected before each use, and at least annually by a qualified person.

2.Before each use, check the soft "O" ring seat at the bullnose of the POL fitting. If the "O" ring is cut, scuffed, or otherwise damaged, replace it with part number 6681.

3.Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.

4.When the heater is to be stored indoors, the connection between the LP-gas supply cylinder(s) and the heater must be disconnected and the cylinder(s) removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum

Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane

Installation Code.

SERVICING

A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:

*The flame is contained within the heater.

*The flame is essentially blue with perhaps some yellow tipping.

*There is no strong disagreeable odor, eye burning or other physical discomfort.

*There is no smoke or soot internal or external to the heater.

*There are no unplanned or unexplained shut downs of the heater.

The parts lists and exploded view show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. IMPORTANT Match the color stripe on the hangtag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Do not use alternates. For this heater, the regulator must be set as shown in "specifications". If there is any uncertainty about the regulator setting, have it checked.

A heater which is not working right must be repaired, but only by a trained, experienced service person.

In-warranty products will be repaired with no charge for either parts or labor. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.

Out-of-warrranty products will be repaired with a charge for parts and labor.

Enerco Group, Inc. Forced Air Propane Construction Heater

5

Operating Instructions and Owner’s Manual

Image 5
Contents MR. Heater General Hazard Warning ContentsSpecifications Natural Gas and Propane Installation Code Operating PrecautionsSafety Precautions Odor Fading ‑ no Odor Detected Odor Fade WarningFuel GAS Odor Servicing Operating InstructionsREF.# ITEM# Description QTY Forced Air Propane Construction Heater Model #35FABtus PER Hour Required Size and Capacity of Propane Cylinders RequiredParts Ordering Information For Information Regarding ServicePAR STALLÉES.SPÉCIALISÉE Treprisenen DE Commande LA SUR Informations0001-251-800 au Dœuvre-mainBTU DE Bonbonnes DES Contenances ET Dimensions DE TableauRequises ANE GAZ Requis Heure ARAppareil chauffagede Fonctionnement DE Instructions Décelée Odeur RetenirFour Votre Avec GaznPas norientezléchappement FonctionnementAU Liées Récautionsp Avertissement AvertissementMatières DES Table MHC * Série Commencement APP
Related manuals
Manual 8 pages 42.16 Kb