Honeywell Switches manual Contents

Page 2

SWITCH APPLICATIONS

The odds are that Honeywell Sensing and Control can meet your switch demands. Designers of heavy-duty equipment have trusted Honeywell pressure and vacuum switches for many years in applications that are constantly subjected to harsh environments…from chemical splashes, salt water, high pressure spikes…we’ve got you covered. Our standard line is quite extensive, but if it is not exactly what your requirements call for we can modify an existing part or create an original just for you. Honeywell has produced millions of custom-built switches for automotive, pool and spa, powershift transmissions, anti-skid braking systems, excavator hydraulic systems, water pump systems, and dental air compressors, to name just a few. Our highly skilled model shop, certified lab and engineering staff can work with you through the design phase, prototype stage, all the way through to the testing phase. And if time is a crucial factor, rapid prototyping technology can now allow us to provide you with a sample in days.

WARNING! Suitability of application is responsibility of user. Extreme heat and vibration should be avoided at mounting points such as on top of an engine over a hot manifold. (MAX operation temp 250° F). Always install by using a wrench on the hex base. Torquing at any other part of the switch voids the warranty or may cause malfunction. A Polyimide film diaphragm is utilized in the pressure switch and is not recommended for use with water. However,

a Teflon diaphragm is available for water applications. Compatibility with the brass or steel external pressure switch material is the responsibility of the user.

For maximum operating pressures see appropriate switch family specifications.

Contact Honeywell Engineering whenever use of switch or fluid compatibility is questioned.

CONTENTS

• Ultra Duty Pressure Switches 10-400 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.3

• Extended Duty Pressure Switches 0.5-150 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.4

• Extended Duty Vacuum Switches1.1-22” Hg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.6

• Extended Duty Piston Switches 200-1000 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.7

• Factory Set Variable Differential Pressure & Vacuum Switches 2-70 psi & 2-22” Hg . . . p.8

• High Pressure Environmentally Sealed Extreme-Duty Switches 35-3000 psi . . . . . . . . . p.9

WARNING

! PERSONAL INJURY

DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury.

2

Image 2
Contents Sensing and Control Contents Metri-Pack Switches SpecificationsApproximate Dead Band Standard Switches Set Points from 10-400 psiSeries Switch With Screw Terminals Standard SpecificationsSwitch Boot P/N 79380 for Vacuum and Pressure Series Switch With Metri-Pack Terminal78630 78631 78628 78629 78711 78712 Blade ScrewBlade 76081 76086 ±0.3 78634 78635 78632 78633 ±0.5Base Brass Set Points from 1.1 to 22 HgPressure Hg vacuum max Burst Pressure 150 PSI 78813 78814 77342 77344 78815 78816 77343 77345With Standard Terminal Piston SwitchSet Points from 200 to 1000 psi Standard Seal NitrileSet Points from 2 to 70 psi and 2 to 22 Hg Diaphragm Type Set Points from 35 to 3000 psiDiaphragm Type Piston Type Conversion Factors Manufacturing Warranty/Remedy Sensing and Control Honeywell Box Springfield, IL