Honeywell Switches manual Set Points from 0.5 to 150 psi, Standard Specifications

Page 4

Set Points from 0.5 to 150 psi

5000 Series Extended Duty Pressure Switch With Direct Action Blade Contacts

The 5000 Series switch is specifically

Standard Specifications

designed to stand up to extended duty

 

 

applications. This switch is factory set

Type:

Direct action

but capable of field adjustment. It

 

blade contact

features a Kapton diaphragm for

 

Contacts:

Silver alloy,

compatibility with a wide variety of

 

gold plated

fluids, and various terminations

 

Set Point:

Factory set

including a Metri-Pack connector that

 

from 0.5 to 150 PSI

forms a tight seal when connected.

 

Operating Pressure:

Among the outstanding design benefits

150 PSI for 0.5-24 PSI set point range,

are its durable construction, compact

250 PSI for 25-150 PSI set point range

size, and enhanced set point integrity. Proof Pressure: 500 PSI

Burst Pressure: 750 PSI for 0.5-24 PSI set point range

1250 PSI for 25-150 PSI set point range.

Switch Boot P/N 79380 for Vacuum and Pressure

2.3” REF.

1.47” REF.

Ratings:

 

 

 

 

 

 

 

 

 

 

 

 

Resistive:

15

AMP-

6

VDC

 

 

 

8

AMP-

12

VDC

 

 

 

4

AMP-

24

VDC

 

 

Inductive:

1

AMP-

120

VAC

2.9” REF.

 

0.5

AMP-

240

VAC

 

 

Diaphragm: Polyimide film

Temperature

Range: -40° F to + 250° F

Connector: 1/8 -27 NPT male thread

Terminals: #8-32 screws, 1/4” blade,

280 Series Metri-Pack

Circuitry: SPST-N.O., N.C.,

1 circuit adjustable dual circuit, or 2 circuits

adjustable dual circuit.

1.47” REF.

Also available are

5000 Series Switch

with Screw Terminals

NOTE: OPERATING MEDIA (PRESSURE SWITCH) The pressure switch is designed to operate with air, motor oils, transmission oils, jet fuels and other similar hydrocarbon media.

 

N.O./N.O. dual circuit

 

and N.C./N.C. dual circuit.

Base:

Plated Steel

Cover:

Glass reinforced polyester

Options:

Brass, plastic or stainless

 

steel base; various base

 

connector thread sizes;

 

wire leads (potted & sealed).

5000 Series Switch

with Metri-Pack Terminal

4

Image 4
Contents Sensing and Control Contents Specifications Approximate Dead Band Standard SwitchesMetri-Pack Switches Set Points from 10-400 psiStandard Specifications Switch Boot P/N 79380 for Vacuum and PressureSeries Switch With Screw Terminals Series Switch With Metri-Pack TerminalBlade Screw Blade78630 78631 78628 78629 78711 78712 76081 76086 ±0.3 78634 78635 78632 78633 ±0.5Set Points from 1.1 to 22 Hg Pressure Hg vacuum max Burst Pressure 150 PSIBase Brass 78813 78814 77342 77344 78815 78816 77343 77345Piston Switch Set Points from 200 to 1000 psiWith Standard Terminal Standard Seal NitrileSet Points from 2 to 70 psi and 2 to 22 Hg Diaphragm Type Piston Type Set Points from 35 to 3000 psiDiaphragm Type Conversion Factors Manufacturing Warranty/Remedy Sensing and Control Honeywell Box Springfield, IL