Honeywell TE22W user manual Battery Installation, LOW Battery Warning, HOW to USE the Table Stand

Page 5

BATTERY INSTALLATION

REMOTE SENSOR

NOTE: Install the batteries; select temperature unit C° or F° before mounting the remote sensor

1.Remove the screws from the battery compartment with a small Phillips screwdriver.

2.Install 2 “AA” size alkaline batteries (not included) matching the polarities shown in the battery compartment.

3.Replace the battery compartment door and secure the screws.

4.Secure remote sensor in the desired location.

MAIN UNIT

1.Open the battery compartment door.

2.Install 2 batteries (UM-3 or “AA” size 1.5V) matching the polarity as shown in the battery compartment.

3.Replace the battery compartment door.

LOW BATTERY WARNING

A low-battery indicator [ ] will appear on the indoor or remote temperature reading line of the main unit warning that the corresponding unit batteries need replacement.

HOW TO USE THE TABLE STAND

The main unit has a removable table stand that supports it on the flat surface. Attach table stand to the bottom of the main unit in the slots provided. The unit can also be mounted on the wall using the recessed screw hole. The table stand must be removed prior to mounting. The remote sensor can be similarly mounted or placed on a flat surface.

GETTING STARTED

After batteries are installed; remote sensor will transmit temperature readings at 45 second intervals.

The main unit may take up to two minutes to receive the initial readings. Upon successful reception, remote temperature will appear on the top line of the main unit’s display. The main unit will automatically update readings at 45-second intervals.

If no signals received from the remote sensor within two minutes, dashes [ ] will be displayed. Press and hold DOWN ( ) button on the main unit for two seconds to initiate another signal search.

7

CHECKING REMOTE AND INDOOR TEMPERATURES The remote temperature information line is located on the top of the main unit’s display.

The wave icon is located above the remote channel number and indicates the reception status from the remote sensor. There are three following types of the reception status that may be displayed.

The unit is in searching mode.

Temperature readings are securely registered.

No signals detected.

˚F

The indoor temperature with the icon IN is located below the remote temperature information line.

NOTE: If the indoor or remote temperature goes above or below operating range stated in specifications, the main unit’s display will show dashes [ ].

WWVB RADIO CONTROLLED TIME

The NIST (National Institute of Standards and Technology) radio station (WWVB) is located in Ft. Collins, Colorado. It transmits an exact time signal continuously throughout the most of the continental United States at 60 KHz frequency. The Wireless Thermometer can receive this WWVB signal through the internal antenna from up to 2,000 miles away. Due to the nature of the Earth’s ionosphere, reception can be limited during the daylight hours. The radio controlled clock will search for an alternate station that receives the atomic time signal from the NIST Atomic clock in Boulder, Colorado.

The WWVB tower icon on the main unit’s display will flash indicating a radio signal reception from the WWVB station. If the tower icon is not fully lit, or if the time and date are not set automatically, please consider the following:

During night-time hours, atmospheric disturbances are typically less severe and radio signal reception may improve. A single daily reception is sufficient enough to keep the clock accuracy within 1 second.

8

Image 5
Contents TE22W Digiview Wireless Thermometer With Atomic ClockFront View IntroductionAlarm Button Mode ButtonRear View Battery Compartment MEM ButtonLED Indicator Remote Sensor FeaturesReset F SwitchLOW Battery Warning Battery InstallationHOW to USE the Table Stand Getting StartedMaximum and Minimum Readings Temperature TrendsLost Communication Transmission CollisionSetting the Alarm Manual SettingsDisabling Alarm PrecautionsFCC Statement Declaration of Conformity Standard Warranty Information