Compaq ML350 Weight, Input Requirements, Line Frequency, BTU Rating, Scsi Connectors

Page 43

QuickSpecs

Compaq ProLiant ML350 Generation 2

Weight

60 lb/27.24 kg (without hard drives)

(approximate)

 

 

Input Requirements

Rated Input Voltage

100 to 120 VAC/200 to 240

(per power supply)

 

VAC

 

Rated Input

50 Hz to 60 Hz

 

Frequency

 

 

Input Power

538W @ 110 VAC

 

Rated Input Current

6A/3A

Line Frequency

50 to 60 Hz

 

BTU Rating

1, 839 BTU/hr

 

SCSI Connectors

Two internal HD68 connectors

Power Supply

Output Power

(per power supply)

Temperature Range

Relative Humidity

(non-condensing)

Acoustic Noise

(Support for either two internal, two external, or a mix of internal/external is available. This is achieved using an internal to external SCSI cable option kit (PN 159547-B21 or PN 159547-B22) and either of the two SCSI knockouts.)

Rated Steady-State

350W

Power

 

Maximum Peak Power 400W

Operating

50° to 93° F/10° to 35° C (No

 

direct sustaining sunlight)

 

Altitude range derating: 33.8°

 

F/1° C per

 

984.25 ft/300 m up to 9,842.5

 

ft/3,000 m

Storage (up to one

-4°to 140° F/-20°to 60° C

year)

 

Altitudes up to 9,842.5 ft/

3,000m

Shipping (up to 72

-20°to 140° F/-29°to 60° C

hours)

 

Altitudes up to

 

29,855.5 ft/

 

9100m

 

Operating

5% to 80%

Non-operating

5% to 90%

Idle

 

(Fixed Disk Drives

 

Spinning)

 

L WAd (BELS)

6.4

L pAm (dBA)

45

Operating

 

(Random Seeks to

 

Fixed Disks)

 

L WAd (BELS)

6.7

L pAm (dBA)

48

DA - 10960 Worldwide QuickSpecs — Version 39 — 2.13.2003

Page 43

Image 43
Contents QuickSpecs QuickSpecsChipset Standard FeaturesCache Memory UpgradabilityGraphics Expansion SlotsStorage InterfacesActiveUpdate Security Server PowerCords Power Supply Industry Standard Compliance ManageabilityQuickSpecs Models ML350R02 P1400- 512KB 256MB Array ML350T02 P1266- 512KB 128MBML350R02 P1400- 512KB 128MB ML350R02 P1266- 512KB 128MB ML350R02 P1266- 512KB 256MB ArrayCountry Code Key Hard drive Options Integrations servicesNetServer to ProLiant Ultra320 Scsi Universal Hot Plug Memory DIMMsOptical Drives Hard DrivesStorage Controllers Communications Wireless HAP SolutionCountry Code Key CRT Country Code Key Redundant OptionsManagement Options MonitorsTFT Country Code Key EUROPE, Middle East and Africa EmeaInternal and External DAT Tape Drives Tape DrivesInternal and External AIT Tape Drives Internal and External DLT VS Tape Drives Internal and External DLT/SDLT Tape DrivesInternal and External LTO Ultrium Tape Drives External SuperLoaderAIT Autoloader Internal and External DAT AutoloaderTape Automation Rackmount Tape Drive Cable KitsEntry Level Tape Libraries SSL2020 Automated AIT Library MSL5026SL Sdlt Library Required Adapters/Controllers for SSL2020 AIT LibraryMSL5052S2 Sdlt Library Departmental Tape Library MSL5052SL Sdlt LibraryMSL5000 series Libraries Options Smart Array Cluster StorageMSL5030 LTO Library MSL5060 LTO LibraryExternal Storage Tower and Rack MSA1000 Cluster OptionsQuickSpecs Volts max output across two Nema UPS OptionsModular PDUs 1U/0U Dual Input PDUs 1U/0U up to 12 outletsOther PDU OptionsRack Builder Rack Conversion Kit HP Rack 10000 Series Rack Options for HP QuickSpecs Rack Options for Rack 7000, 9000 and 10000 Series Country Code Key for 1U Rack Keyboard & Drawer PN Hardware Services 4-Hour On-site Service Service and Support Offerings CarePaqInstallation & Start-up Services QuickSpecs Standard Memory Replaced with Optional Memory MemoryCompaq ProLiant ML350 G2 Array Models Standard Memory Standard Memory Plus Optional MemoryCompaq ProLiant ML350 G2 Models Standard Memory StorageQuantity Position Supported Controller Removable Media Quantity Position Supported Controller Ultra320 Hot Pluggable DrivesInch External StoragePlug Scsi Drive Power Specifications Country Power Cord Part NumberSystem Unit Tower Dimensions TechSpecsTemperature Range Relative Humidity WeightScsi Connectors Power Supply Output PowerOutput Power per System Unit Rack DimensionsTemperature Range Per Diskette high/low MB Diskette Drive LED Indicators frontAccess Times Read/Write CapacityConnector External Scsi ConnectorsInternal Scsi Connectors Support ResolutionQuickSpecs