Installation

Basic Operation

In order for the Optimus to operate properly, an application program must be loaded onto the PDT. It is possible for the Optimus to power up without at active application. On power up if the Optimus has no application program loaded, then the following Application Program menu options will appear on the display:

MENU OPTIONS.

Download

Activate

Upload

DESCRIPTION

This option allows the user to download application programs (*.SHX), BASIC run-time (bas.ops.shx), BASIC programs (*.SYN) or font files to the terminal. There are 6 resident locations and one Active Memory. A maximum of 7 programs can be downloaded to the terminal. The application program downloaded to the Active Memory will be the only activate program running. In order to activate one of the other programs, immediately after downloading, input a name for the program desired or just press the enter key to keep its current name if one is applicable. This will enable the user to download the program. The application program’s type, name, and size will be shown on the list of programs when entering the Download or Activate menu of the Program Manager. The file type is a small letter that follows the program number (01~06), it can be either ‘b’, ‘c’ or ‘f’ which represents BASIC program, C program or font file respectively. The program name is up to 12 characters and the program size is in units of K bytes.

NOTE: In order to delete a program, select the program designated for deletion. From the program information screen, press the Alpha/Function key, then zero.

This option will enable the use to activate one of the resident programs. In order to accomplish this, the user must copy one of the 6 resident programs to the Active Memory. Upon activation of the new program the original program in the Active Memory will be replaced. Note: A font file cannot be activated, and a BASIC program cannot be activated if the BASIC run-time does not exist.

The Upload option gives the user additional method for retrieving an application program. It allows a user to transmit the application programs to a host PC or another terminal. This function also allows a terminal to be cloned without going through a PC.

Selecting and successfully completing one of these three menu options will enable the OptimusS to begin functional operation.

Communication and Data Collection Setup

The OptimusS Series has various ways of communicating with a host device. Depending on the model of Optimus, it can communicate via RS232, USB, or via a wireless Bluetooth connection. The two models available are the OptimusS Batch (SP5502) and OptimusS/Bluetooth (SP5535). These two models have various ways of data collection as well. Depending on the model it may store the data on the terminal itself or transmit live data back to a host device.

The SP5502 stores data in the unit and has the ability to utilize a RS232 or USB connection to communicate to a host device for both application program downloads and data uploads. The SP5502 includes either a USB or RS232 cable. In order to begin an application download or data transfer the following steps would need to be followed.

1.Remove the Optimus cradle, the power supply, and either the USB or RS232 cable from the box.

2.Plug the power supply into a power outlet and insert the other end into the cradle. The red LED on the cradle will illuminate if the power supply is connected correctly.

9

Image 10
Contents SP5500 OptimusS Series User’s Guide Page Table of Contents Page Introduction Scanner and AccessoriesProduct Overview General Features and Characteristics Item no DescriptionMultifunctional Keypad 3BSLithium-Ion Battery LCD ScreenInstallation Getting StartedCommunication and Data Collection Setup Basic OperationInstallation Data Upload System Menu Options Information Settings Tests Memory Power Load ProgramSystem Module InformationLCD & LED Initialize Size InfoLoad Application Programming the terminal ApplicationRun Program Utilities Programming the communication cradleTroubleshooting SymptomCPU SpecificationsMB Sram EMC Scan AreasContact Information and Office Locations Corporate HeadquartersSouth America and Central America Brazil MercSafety Notices