Metrologic Instruments MS6520 manual Appendix E, Remarque

Page 44

APPENDIX E

Notices

Notice

This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Any unauthorized changes or modifications to this equipment could void the users authority to operate this device.

Notice

This Class A digital apparatus complies with Canadian ICES-003.

Caution

Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard.

Remarque

Cet appareil numérique de la classe A est conformé a la norme NMB-003 du Canada.

Attention

L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou le laser. Ne regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez à une rayonnement laser mortel. L'emploi d'appareils optiques avec cet équipement laser augmente le risque d'endommagement de la vision.

Achtung

Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine lebensgefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät hineinzusehen. Wenn Sie dies tun, können Sie sich einer lebensgefährlichen Laserstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung.

Attenzione

L’utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale può provocare dei raggi laser pericolosi per la vita. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai nel raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Se tuttavia lo fate, potete esporVi a dei raggi laser pericolosi per la vita. L’uso di apparecchi ottici con questo equipaggiamento laser aumenta il rischio di danni alla vista.

37

Image 44
Contents Metrologic INSTRUMENTS, INC Page Locations Iii Table of Contents Table of Contents Printer Note Leave page blank Introduction Scanner InterfaceScanner and Accessories ∙ Keyboard Wedge Powerlink and Adapter Cable MlpnQuick Start Installing the IS6520-41/MS6520-41TO the Host System Installing the IS6520-47/MS6520-47 to the PC Manufacturer’s RecommendationPage Disconnecting the Powerlink Cables from the Scanner Powerlink Cable Scanner PartsSpeaker Green & Red LEDsMounting Holes Audible Indicators Three Beeps On Power UpOne Beep Razzberry ToneFlashing Green and Red and Two Razzberry Tones Failure ModesFlashing Green and One Razzberry Tone Visual Indicators Programming Modes How does Serial Programming work?‘3’ should not be SENT, IT is a Code Type Designation only Abreviated Ascii Table Page Maintenance LabelsMils Optimal LOW and Close Depth of FieldMinimum Bar Code Element Width Optimal High and Normal Depth of Field FAR Depth of Field Troubleshooting Guide IS6520/MS6520 Series Troubleshooting GuideSymptoms Possible Causes Solution Troubleshooting Guide RS-232 only Mechanical Appendix aOperational Electrical EnvironmentalMinimum Symbol Length Symbol Length Lock Appendix BDTS/NIXDORF NCR F NCR S Baud Rate Character RTS/CTS ACK/NA K Cable Connector Configurations Appendix CScanner Pinout Connections Keyboard Wedge Pin FunctionKeyboard Wedge Powerlink and Adapter Cable Mlpn PowerLink Cable Pin Female DINPin Male Mini-DIN Adapter Cable Pin Male DINNo Connect Warranty and Disclaimer Limited Warranty Appendix DFAX Appendix E RemarqueEuropean Standard Funkstöreigenschaften nach ENStandard Europeo WarnungAppendix F PatentsIndex 24, 26, 27, 28Iv, 3, 6

MS6520 specifications

The Metrologic Instruments MS6520 is a sophisticated and versatile bar code scanner designed to meet the demands of various industries, including retail, manufacturing, and logistics. Known for its durability and efficiency, the MS6520 combines advanced technology with user-friendly features to provide a seamless scanning experience.

One of the standout features of the MS6520 is its laser scanning technology. Equipped with a high-performance laser, the scanner provides rapid and accurate barcode decoding, even on damaged or poorly printed barcodes. With a scanning speed of up to 100 scans per second, the MS6520 significantly enhances operational efficiency, allowing users to process transactions swiftly.

The MS6520 is designed to handle a wide range of barcodes, including 1D barcodes such as UPC, EAN, and Code 39, as well as some 2D barcodes depending on the model variant. This versatility makes it an ideal solution for businesses that require adaptability in their scanning needs. The scanner also supports various interfaces, including USB, RS-232, and PS/2, ensuring compatibility with a variety of systems and devices.

In terms of ergonomics, the MS6520 is lightweight and comfortable to hold. Its ergonomic design reduces strain during extended use, making it suitable for environments where continuous scanning is required. The scanner's robust construction ensures durability, providing resistance to drops and harsh conditions, which is especially beneficial in busy retail or warehouse settings.

Another key characteristic of the MS6520 is its ability to operate in various environments. The scanner is designed to function effectively in low-light conditions and can cope with challenging environments such as warehouses and outdoor locations. Additionally, the scanner's intuitive design allows for easy one-handed operation, increasing user productivity.

The MS6520 also supports advanced features such as programmable settings, enabling users to customize the scanner according to their specific needs. It includes features such as data formatting and multi-interface support, which can be particularly valuable for business applications requiring specific data outputs.

In summary, the Metrologic Instruments MS6520 is a top-tier barcode scanner that combines high-speed scanning with robust performance and flexible connectivity options. Its ergonomic design, durability, and adaptability make it an excellent choice for businesses looking to streamline their operations and improve efficiency in barcode scanning tasks.