1/4-20 X 3 LG HEX HEAD SCREW & LOCK WASHER
1/4-20 WELD NUT
Figure 5.5.9b Retainer Bolt Installation
CABLE CHANNELS
Figure 5.5.9c Cable Routing
1.Install at least one of the supplied 1/4-20 X 3 in Retainer Bolt with its lock washer through the side of either the top or bottom Wall/Enclosure Bracket and snugly tighten. The bolt threads into a weld nut on the side of the Wall Bracket. This Retainer Bolt prevents the enclosure from being lifted off the Wall Brackets without first removing the bolt. Note that the Retainer Bolt does not “clamp” or support anything. It serves only to retain the enclosure on the wall brackets, not to lock it into position.
2.Route cabling as required using the rear channels in the enclosures extrusion.
3.Rotate the enclosure to the desired horizontal angle. Firmly tighten each Enclosure Bracket Bolt to secure the enclosure in the desired position.