Siemens TC65 manual Change to Secured Mode Concept, Generate key pair

Page 74

TC65 JAVA User's Guide

Strictly confidential / Released

s

11.2.1Change to Secured Mode Concept

generate key pair

private key

Customer Environment

public key

generate customer root

certificate

Customer Root Certificate

(X.509)

public key from issuer of the certificate

binary data of certificate

build binary data for AT command AT^SJSEC

AT^SJSEC

cmd len

cmd id

binary data of certificate

signature

Computer

send to module

Module

Figure 43: Switch to Security Mode

TC65 JAVA User's Guide_V05

Page 74 of 90

26.09.2005

Image 74
Contents Java Users Guide September 26 Document Name TC65 Java Users GuideTC65 Java Users Guide TC65 Java Users GuideV05Table of Contents Maintenance 3.3.2Java Security Compile and Run a Program without a Java IDEDebug Environment Java Tutorial Differences from the TC45Sun Java Studio Mobility 6 Switching Emulators TablesPreamble Related Documents New solutionOverview Terms and Abbreviations Abbreviation DescriptionSystem Requirements InstallationInstallation CD 1.2 WTK ComponentsModule Exchange Suite SDK and Java StudioInstalling the Smtk Environment Siemens Mobility Toolkit InstallationInstalling the Standard Development Toolkit Installing Module Exchange Suite MES Installing Sun Java Studio MobilityInstalling Eclipse Installing Borland JBuilder X Smtk Uninstall UpgradesSoftware Platform Software Architecture3 DAC/ADC Interfaces 1 ASC0 Serial DeviceGeneral Purpose I/O 4 ASC1Media JVM InterfacesIP Networking Other InterfacesData Flow of a Java Application Running on the Module ADCHandling Interfaces and Data Service Resources Module StatesState 2 No Java Running, General Purpose I/O and I2C State 1 Default No Java RunningState 4 Default Java Application Active State 3 No Java Running, General Purpose I/O and SPIState 5 Java Application Active, General Purpose I/O and I2C Module State Transitions Maintenance IP ServicePower Saving ChargingShutdown Airplane ModeAlarm Automatic ShutdownSwitching from Data Mode to Command Mode Restart after Switch OffSpecial AT Command Set for Java Applications Mode Indication after MIDlet StartupRestrictions Flash File System Configuration of Serial InterfaceJava Commands MemoryFrequencyB 1 / frequencyA PerformanceJava Duration of each loop = 600 sPin I/O Data Rates on RS-232 APIPlain Serial Interface Voice Call in Parallel75% 63% 55% 33% Scenarios with Gprs ConnectionUpload 65% 55% 33% 16%85% 78% 58% 48% Download91% 87% 81% 73% MIDlets MIDlet Documentation MIDlet Life CycleMIDlet.destroyApp method Hello World MIDlet Here is a sample HelloWorld programModule Exchange Suite Command Line BasedFile Transfer to Module Windows BasedOtap Security IssuesOver the Air Provisioning Otap Overview Over The Air Provisioning OtapIntroduction to Otap Parameters Max. Length AT Keyword SM Install/update Delete Otap ParametersDelete operation Install operationShort Message Format Java File Format Procedures Install/Update Delete Time Out Values and Result Codes Tips and Tricks for OtapOtap Tracer SecurityHow To Compile and Run a Program without a Java IDE Build ResultsRun on the Module with Autostart CompileRun on the Module with Manual Start Switch on Autostart Switch off AutostartDebug Environment Data Flow of a Java Application in the Debug EnvironmentEmulator Java IDE Sun Java Studio Mobility 6 2004Q3 Switching emulators Projects Compile and run TemplatesExamples JBuilderX JDK settings Borland JBuilderExamples TC65 Java Users Guide JBuilder2005 JDK settings Eclipse IntegrationEclipse Plug-in installation Eclipse J2ME platform TC65 Java Users GuideV05 26.09.2005 Example Eclipse Project importEclipse Example Compile and debug Eclipse Create packageEclipse Configuration BreakpointsJava Security Secure Data Transfer ModeAsja Vasecuritycertificate J a va C u r i t y c e r t i f i c a t eCreate a Secure Data Transfer Environment Step by Step Create CA and generate CA Root CertificateExecution Control Unsecured modeSecured mode Generate key pair Change to Secured Mode ConceptBuild binary data for AT command Atsjsec Generate customer root CertificateConcept for the Signing the Java MIDlet Encoded JAR-File HashStructure and Description of the Java Security Commands Application and Data ProtectionStructure of the Java Security Commands General structureBuild Java Security Command Hash SHA1Send Java Security Command to the Module ATSJSEC?Create Java Security Commands Export X.509 Root CertificateCommand switch off module exchange functionality Sign a MIDletJava Tutorial Using the AT Command APIClass ATCommand Instantiation with or without CSD SupportSending an AT Command to the Device, the send Method Data ConnectionsTC65 Java Users Guide Synchronization ATCommandResponseListener InterfaceNon-blocking ATCommand.send Method Implementation ATCommandListener InterfaceATEvents Registering a Listener with an ATCommand Instance Example Programming the MIDletThreads TC65 Java Users Guide Differences from the TC45
Related manuals
Manual 123 pages 53.3 Kb

TC65 specifications

The Siemens TC65 is a compact and powerful GSM/GPRS module designed for a wide range of mobile communication applications. With its robust features, the TC65 perfectly meets the growing demands for connectivity in various industries, including automotive, telematics, and industrial automation.

A standout feature of the TC65 is its compact size, allowing it to be easily integrated into various devices without compromising on performance. The module supports GSM (Global System for Mobile Communications) and GPRS (General Packet Radio Service), providing reliable and efficient voice and data transmission.

One of the key technologies incorporated in the TC65 is its integrated TCP/IP stack, which allows for seamless internet connectivity and enables application developers to create IoT solutions with ease. This capability is essential for remote monitoring, data logging, and other applications that require continuous data exchange.

The TC65 also boasts extensive multimedia capabilities, including support for SMS, MMS, and voice calls. This makes it suitable for applications that require not only data transmission but also communication features. Additionally, it supports various codecs for voice compression, ensuring high-quality audio in voice applications.

Enhanced security features are another highlight of the TC65. It incorporates comprehensive security protocols to safeguard data transmission, making it suitable for sensitive applications in finance, healthcare, and other critical sectors. The module also includes an integrated SIM application toolbox that supports the development of secure and customizable applications.

For developers, the TC65 offers an easy-to-use software development kit (SDK), simplifying the process of application development. This means that businesses can quickly create and deploy solutions tailored to their specific needs.

The module operates across a wide voltage range and is designed to tolerate challenging environmental conditions, making it ideal for industrial use. It supports various interfaces, including UART, GPIO, and I2C, enabling it to connect with a variety of peripherals and sensors, thus expanding its usability.

In summary, the Siemens TC65 combines compact design, versatile communication capabilities, advanced security features, and developer-friendly resources, making it an excellent choice for anyone looking to implement reliable and sophisticated GSM/GPRS communication in their applications. The TC65 is a valuable asset in the evolving landscape of connected devices and IoT solutions.