Siemens manual Document Name TC65 Java Users Guide, September 26, TC65 Java Users GuideV05

Page 2

TC65 JAVA User's Guide

s

 

Strictly confidential / Released

 

 

 

 

 

Document Name: TC65 JAVA User's Guide

 

 

Version:

05

 

 

Date:

September 26, 2005

 

 

DocId:

TC65 JAVA User's Guide_V05

 

 

Status:

Strictly confidential / Released

 

 

 

 

 

 

General Notes

Product is deemed accepted by recipient and is provided without interface to recipient’s products. The documentation and/or product are provided for testing, evaluation, integration and information purposes. The documentation and/or product are provided on an “as is” basis only and may contain deficiencies or inadequacies. The documentation and/or product are provided without warranty of any kind, express or implied. To the maximum extent permitted by applicable law, Siemens further disclaims all warranties, including without limitation any implied warranties of merchantability, completeness, fitness for a particular purpose and non-infringement of third-party rights. The entire risk arising out of the use or performance of the product and documentation remains with recipient. This product is not intended for use in life support appliances, devices or systems where a malfunction of the product can reasonably be expected to result in personal injury. Applications incorporating the described product must be designed to be in accordance with the technical specifications provided in these guidelines. Failure to comply with any of the required procedures can result in malfunctions or serious discrepancies in results. Furthermore, all safety instructions regarding the use of mobile technical systems, including GSM products, which also apply to cellular phones must be followed. Siemens or its suppliers shall, regardless of any legal theory upon which the claim is based, not be liable for any consequential, incidental, direct, indirect, punitive or other damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information or data, or other pecuniary loss) arising out the use of or inability to use the documentation and/or product, even if Siemens has been advised of the possibility of such damages. The foregoing limitations of liability shall not apply in case of mandatory liability, e.g. under the German Product Liability Act, in case of intent, gross negligence, injury of life, body or health, or breach of a condition which goes to the root of the contract. However, claims for damages arising from a breach of a condition, which goes to the root of the contract, shall be limited to the foreseeable damage, which is intrinsic to the contract, unless caused by intent or gross negligence or based on liability for injury of life, body or health. The above provision does not imply a change on the burden of proof to the detriment of the recipient. Subject to change without notice at any time. The interpretation of this general note shall be governed and construed according to German law without reference to any other substantive law.

Copyright

Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved.

Copyright © Siemens AG 2005

Trademark notices

MS Windows® is a registered trademark of Microsoft Corporation.

Java™ and Sun™ Java Studio Mobility 6 2004Q3 are registered trademarks of Sun Microsystems Inc. Borland® JBuilder® is a registered trademark of Borland Software Corporation

TC65 JAVA User's Guide_V05

Page 2 of 90

26.09.2005

Image 2
Contents Java Users Guide September 26 Document Name TC65 Java Users GuideTC65 Java Users Guide TC65 Java Users GuideV05Table of Contents Maintenance 3.3.2Java Security Compile and Run a Program without a Java IDEDebug Environment Java Tutorial Differences from the TC45Sun Java Studio Mobility 6 Switching Emulators TablesPreamble Related Documents New solutionOverview Terms and Abbreviations Abbreviation DescriptionSystem Requirements InstallationInstallation CD 1.2 WTK ComponentsModule Exchange Suite SDK and Java StudioInstalling the Smtk Environment Siemens Mobility Toolkit InstallationInstalling the Standard Development Toolkit Installing Module Exchange Suite MES Installing Sun Java Studio MobilityInstalling Eclipse Installing Borland JBuilder X Smtk Uninstall UpgradesSoftware Platform Software Architecture3 DAC/ADC Interfaces 1 ASC0 Serial DeviceGeneral Purpose I/O 4 ASC1Media JVM InterfacesIP Networking Other InterfacesData Flow of a Java Application Running on the Module ADCHandling Interfaces and Data Service Resources Module StatesState 2 No Java Running, General Purpose I/O and I2C State 1 Default No Java RunningState 4 Default Java Application Active State 3 No Java Running, General Purpose I/O and SPIState 5 Java Application Active, General Purpose I/O and I2C Module State Transitions Maintenance IP ServicePower Saving ChargingShutdown Airplane ModeAlarm Automatic ShutdownSwitching from Data Mode to Command Mode Restart after Switch OffSpecial AT Command Set for Java Applications Mode Indication after MIDlet StartupRestrictions Flash File System Configuration of Serial InterfaceJava Commands MemoryFrequencyB 1 / frequencyA PerformanceJava Duration of each loop = 600 sPin I/O Data Rates on RS-232 APIPlain Serial Interface Voice Call in Parallel75% 63% 55% 33% Scenarios with Gprs ConnectionUpload 65% 55% 33% 16%85% 78% 58% 48% Download91% 87% 81% 73% MIDlets MIDlet Documentation MIDlet Life CycleMIDlet.destroyApp method Hello World MIDlet Here is a sample HelloWorld programModule Exchange Suite Command Line BasedFile Transfer to Module Windows BasedOtap Security IssuesOver the Air Provisioning Otap Overview Over The Air Provisioning OtapIntroduction to Otap Parameters Max. Length AT Keyword SM Install/update Delete Otap ParametersDelete operation Install operationShort Message Format Java File Format Procedures Install/Update Delete Time Out Values and Result Codes Tips and Tricks for OtapOtap Tracer SecurityHow To Compile and Run a Program without a Java IDE Build ResultsRun on the Module with Autostart CompileRun on the Module with Manual Start Switch on Autostart Switch off AutostartDebug Environment Data Flow of a Java Application in the Debug EnvironmentEmulator Java IDE Sun Java Studio Mobility 6 2004Q3 Switching emulators Projects Compile and run TemplatesExamples JBuilderX JDK settings Borland JBuilderExamples TC65 Java Users Guide JBuilder2005 JDK settings Eclipse IntegrationEclipse Plug-in installation Eclipse J2ME platform TC65 Java Users GuideV05 26.09.2005 Example Eclipse Project importEclipse Example Compile and debug Eclipse Create packageEclipse Configuration BreakpointsJava Security Secure Data Transfer ModeAsja Vasecuritycertificate J a va C u r i t y c e r t i f i c a t eCreate a Secure Data Transfer Environment Step by Step Create CA and generate CA Root CertificateExecution Control Unsecured modeSecured mode Generate key pair Change to Secured Mode ConceptBuild binary data for AT command Atsjsec Generate customer root CertificateConcept for the Signing the Java MIDlet Encoded JAR-File HashStructure and Description of the Java Security Commands Application and Data ProtectionStructure of the Java Security Commands General structureBuild Java Security Command Hash SHA1Send Java Security Command to the Module ATSJSEC?Create Java Security Commands Export X.509 Root CertificateCommand switch off module exchange functionality Sign a MIDletJava Tutorial Using the AT Command APIClass ATCommand Instantiation with or without CSD SupportSending an AT Command to the Device, the send Method Data ConnectionsTC65 Java Users Guide Synchronization ATCommandResponseListener InterfaceNon-blocking ATCommand.send Method Implementation ATCommandListener InterfaceATEvents Registering a Listener with an ATCommand Instance Example Programming the MIDletThreads TC65 Java Users Guide Differences from the TC45
Related manuals
Manual 123 pages 53.3 Kb

TC65 specifications

The Siemens TC65 is a compact and powerful GSM/GPRS module designed for a wide range of mobile communication applications. With its robust features, the TC65 perfectly meets the growing demands for connectivity in various industries, including automotive, telematics, and industrial automation.

A standout feature of the TC65 is its compact size, allowing it to be easily integrated into various devices without compromising on performance. The module supports GSM (Global System for Mobile Communications) and GPRS (General Packet Radio Service), providing reliable and efficient voice and data transmission.

One of the key technologies incorporated in the TC65 is its integrated TCP/IP stack, which allows for seamless internet connectivity and enables application developers to create IoT solutions with ease. This capability is essential for remote monitoring, data logging, and other applications that require continuous data exchange.

The TC65 also boasts extensive multimedia capabilities, including support for SMS, MMS, and voice calls. This makes it suitable for applications that require not only data transmission but also communication features. Additionally, it supports various codecs for voice compression, ensuring high-quality audio in voice applications.

Enhanced security features are another highlight of the TC65. It incorporates comprehensive security protocols to safeguard data transmission, making it suitable for sensitive applications in finance, healthcare, and other critical sectors. The module also includes an integrated SIM application toolbox that supports the development of secure and customizable applications.

For developers, the TC65 offers an easy-to-use software development kit (SDK), simplifying the process of application development. This means that businesses can quickly create and deploy solutions tailored to their specific needs.

The module operates across a wide voltage range and is designed to tolerate challenging environmental conditions, making it ideal for industrial use. It supports various interfaces, including UART, GPIO, and I2C, enabling it to connect with a variety of peripherals and sensors, thus expanding its usability.

In summary, the Siemens TC65 combines compact design, versatile communication capabilities, advanced security features, and developer-friendly resources, making it an excellent choice for anyone looking to implement reliable and sophisticated GSM/GPRS communication in their applications. The TC65 is a valuable asset in the evolving landscape of connected devices and IoT solutions.